UV-Visible Spectrophotometer, Double Beam
Double-beam UV-Vis spectrophotometer for quantitative absorbance and scanning work.
Typical applications
- Quantitative assay by absorbance
- COD, nitrate, phosphate and metals colorimetry
- Dissolution and content uniformity testing
Conforms to
- USP <857>—Ultraviolet-Visible Spectroscopy
Add to enquiry
Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.
Worth knowing before you order
Pharmaceutical customers should specify the 21 CFR Part 11 software package and IQ/OQ/PQ documentation at enquiry stage. Retrofitting them after installation costs more and delays qualification.Specification
| Wavelength range | 190–1100 nm |
|---|---|
| Spectral bandwidth | 1 nm (2 nm and variable on selected models) |
| Wavelength accuracy | ± 0.3 nm |
| Photometric range | −0.3 to 3.0 A |
| Stray light | < 0.05% T at 220 nm |
| Software | PC control; 21 CFR Part 11 package to order |
Support available
- Installation & commissioning
- Calibration
- Validation & qualification (IQ/OQ/PQ)
- Operator training
- Annual maintenance contract
- Spares & consumables
Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.
Related products
Analytical Balance, 220 g × 0.1 mg
Four-decimal analytical balance with draught shield and internal or external calibration.
Ex-stockISO/IEC 17025Capacity: 220 g
Specification for Analytical Balance, 220 g × 0.1 mg
Specification for Analytical Balance, 220 g × 0.1 mg Capacity 220 g Readability 0.1 mg (0.0001 g) Repeatability ≤ 0.1 mg Linearity ± 0.2 mg Pan size 90 mm ø Calibration Internal motorised or external OIML class E2 weight Services Installation & commissioning · Calibration · Operator training · Annual maintenance contract Standards
ISO/IEC 17025Typical applications
- Weighing for standard and reagent preparation
- Gravimetric analysis
- Sample weighing for assay
Full record, hazard data and enquiry for Analytical Balance, 220 g × 0.1 mg →
pH Meter, Benchtop, Five-Point Calibration
Microprocessor benchtop pH and mV meter with automatic temperature compensation and up to five-point calibration.
Ex-stockpH range: −2.00 to 16.00
Specification for pH Meter, Benchtop, Five-Point Calibration
Specification for pH Meter, Benchtop, Five-Point Calibration pH range −2.00 to 16.00 pH resolution 0.01 (0.001 on selected models) Accuracy ± 0.01 pH Calibration points Up to 5, with auto buffer recognition Temperature ATC, −10 to 110 °C Output RS-232 / USB, optional printer Services Installation & commissioning · Calibration · Operator training · Annual maintenance contract · Spares & consumables Typical applications
- pH measurement in water, effluent and process samples
- Pharmaceutical QC pH determination
Full record, hazard data and enquiry for pH Meter, Benchtop, Five-Point Calibration →
Kjeldahl Digestion and Distillation Unit
Digestion block with fume scrubber and steam distillation unit for total nitrogen and crude protein determination.
IndentDigestion positions: 3, 6, 8 or 12
Specification for Kjeldahl Digestion and Distillation Unit
Specification for Kjeldahl Digestion and Distillation Unit Digestion positions 3, 6, 8 or 12 Digestion temperature Up to 450 °C, PID controlled Fume scrubber Water aspirator or recirculating, with neutralisation Distillation Steam generator with automatic alkali dosing Recovery ≥ 99.5% on ammonium sulphate reference Site preparation Required — foundation or utilities Services Installation & commissioning · Calibration · Operator training · Annual maintenance contract · Spares & consumables Typical applications
- Crude protein in food and feed
- Total Kjeldahl nitrogen in water and effluent
- Nitrogen in soil and fertiliser
Full record, hazard data and enquiry for Kjeldahl Digestion and Distillation Unit →
Conductivity / TDS Meter, Benchtop and Portable
Conductivity, TDS, salinity and resistivity measurement with automatic temperature compensation.
Ex-stockUSP <645>Conductivity range: 0.01 µS/cm to 200 mS/cm, auto-ranging
Specification for Conductivity / TDS Meter, Benchtop and Portable
Specification for Conductivity / TDS Meter, Benchtop and Portable Conductivity range 0.01 µS/cm to 200 mS/cm, auto-ranging Accuracy ± 0.5% of full scale Cell constants K = 0.1, 1.0 and 10.0 Temperature ATC with selectable coefficient Services Calibration · Operator training · Annual maintenance contract · Spares & consumables Standards
USP <645>Typical applications
- Purified water system monitoring
- Effluent and process water conductivity
- TDS in drinking water
Full record, hazard data and enquiry for Conductivity / TDS Meter, Benchtop and Portable →