Testing & Laboratory Instruments
Material testing, analytical, microbiology and thermal equipment. Every instrument carries the standard it is built to satisfy — checked against the issuing body, with superseded and withdrawn references shown as such rather than quietly reprinted.
20 categories · 244 published records. The catalogue we can supply is broader than the catalogue we publish — send us the item if you cannot find it.
Compression testing machines, workability apparatus, cement fineness and setting-time equipment, moulds and non-destructive testing.
Compression Testing Machine, 2000 kN, Digital
Digital compression testing machine with controlled pace rate for concrete cubes, cylinders and cement mortar specimens.
IndentIS 14858Capacity: 2000 kN (also 500, 1000, 1500 and 3000 kN)
Slump Test Apparatus
Slump cone, base plate and tamping rod for measuring the workability of fresh concrete.
Ex-stockIS 1199 (Part 2) : 2018Cone dimensions: 200 mm bottom ø × 100 mm top ø × 300 mm high
Vicat Needle Apparatus
Determines standard consistency and initial and final setting time of cement paste.
Ex-stockIS 5513Plunger: 10 ± 0.05 mm ø × 50 ± 1 mm long
Le Chatelier Mould, Set of Six
Split brass cylinders with indicator arms for determining the soundness of cement by expansion.
Ex-stockIS 4031 (Part 3)Cylinder: 30 mm internal ø × 30 mm high, 0.5 mm wall
Blaine Air Permeability Apparatus
Determines the fineness of cement and pozzolana as specific surface area by air permeability.
IndentIS 4031 (Part 2)Permeability cell: Brass, with perforated disc and plunger
Ultrasonic Pulse Velocity Tester
Non-destructive assessment of concrete homogeneity, cracking and quality by ultrasonic pulse transit time.
IndentIS 516 (Part 5/Sec 1) : 2018Transducers: Matched pair, 54 kHz standard
CBR and compaction apparatus, Atterberg limits, shear strength, permeability, in-situ density and consolidation equipment.
CBR Testing Machine, Motorised, with Proving Ring
Motorised load frame for determining the California Bearing Ratio of subgrade and pavement layer materials.
IndentIS 2720 (Part 16)Frame capacity: 50 kN
Liquid Limit Device (Casagrande), Hand Operated
Casagrande cup apparatus for determining the liquid limit and, with the grooving tools, the plasticity characteristics of soil.
Ex-stockIS 2720 (Part 5)Cup: Brass, standard Casagrande profile
Compaction Rammer, Light — 2.6 kg, 310 mm Drop
Standard Proctor rammer for the light compaction test — 2.6 kg mass falling through 310 mm.
Ex-stockIS 2720 (Part 7)Rammer mass: 2.6 kg
Compaction Rammer, Heavy — 4.89 kg, 450 mm Drop
Modified Proctor rammer for the heavy compaction test — 4.89 kg mass falling through 450 mm.
Ex-stockIS 2720 (Part 8)Rammer mass: 4.89 kg
Direct Shear Apparatus, Motorised
Shear box apparatus for determining the cohesion and angle of internal friction of soil.
IndentIS 2720 (Part 13)Shear boxes: 60 × 60 mm and 100 × 100 mm
Core Cutter Apparatus for Field Density
Core cutter, dolly and rammer set for determining in-situ dry density of cohesive soil.
Ex-stockIS 2720 (Part 29)Core cutter: 100 mm internal ø × 130 mm long
Abrasion, impact and crushing value apparatus, shape gauges, specific gravity equipment, test sieves and sieve shakers.
Los Angeles Abrasion Testing Machine
Rotating drum with steel charge for determining the abrasion resistance of coarse aggregate.
IndentIS 2386 (Part 4)Drum: 700 mm internal ø × 500 mm internal length
Aggregate Impact Testing Machine
Determines the aggregate impact value — resistance to sudden shock as distinct from gradual load.
Ex-stockIS 2386 (Part 4)Hammer mass: 13.5–14.0 kg
Aggregate Crushing Value Test Apparatus
Cylinder, plunger and base plate set for determining aggregate crushing value under gradually applied compressive load.
Ex-stockIS 2386 (Part 4)Cylinder: 150 mm internal ø
Test Sieves — Woven Wire and Perforated Plate
Stainless steel and brass test sieves in 200 mm, 300 mm and 450 mm frame sizes, with matching lids and receivers.
Ex-stockIS 460 (Part 1) : 2020Fine sieves (200 mm): 10 µm to 600 µm woven wire
Sieve Shaker — Electromagnetic and Rotap
Mechanical sieve shakers with timer control, in electromagnetic and rotary-tapping configurations.
IndentIS 1607Electromagnetic: Amplitude control, digital timer, 200 mm sieve stack
Penetration, softening point and ductility apparatus, Marshall stability equipment, binder ageing ovens and viscosity measurement.
Marshall Stability Testing Machine, Digital
Load frame with breaking head and flow measurement for determining the stability and flow of bituminous mixtures.
IndentASTM D6927Capacity: 50 kN
Penetrometer, Fully Automatic — Bitumen, Grease, Petrolatum and Wax
Optoelectronic penetrometer covering needle penetration of bitumen and petroleum wax and cone penetration of lubricating grease and petrolatum, with motorised placement and a 0.01 mm readout.
Ex-stockIS 1203 : 2022Test condition, bitumen: 100 g total load, 5 s, 25 °C
Ring and Ball Apparatus, Automatic (Softening Point)
Automatic softening point apparatus with programmable heating rate and optical ball detection.
IndentIS 1205 : 2022Heating rate: 5 °C/min ± 0.5 °C/min, programmable, as IS 1205 requires
Ductility Testing Machine, Refrigerated
Water-bath ductility machine with integrated refrigeration and precise temperature control.
IndentIS 1208 (Part 1) : 2023Test temperature: 25 °C ± 0.1 °C, refrigerated to ~10 °C
Rolling Thin Film Oven (RTFO)
Simulates the short-term ageing a binder undergoes during mixing and laydown.
IndentASTM D2872Test temperature: 163 °C ± 0.5 °C
Wide-width tensile, grab, puncture, permittivity and pore-size testing for geotextiles, geomembranes, geogrids and geocomposites.
Geotextile Universal Testing Machine
Universal testing frame supplied with the five fixtures the ASTM geotextile methods call for — grab, index puncture, CBR puncture, trapezoid tear and wide-width tensile.
IndentASTM D4632/D4632MFixtures supplied: Grab test; index puncture; CBR puncture using a 50 mm probe; trapezoid tear; wide-width tensile
Apparent Opening Size Tester for Geotextiles
Sieve shaker set up for the dry glass-bead method that fixes a geotextile's apparent opening size — the O95 figure a filtration design is checked against.
IndentASTM D4751Determines: Apparent opening size, reported as O95 in mm under ASTM D4751; characteristic opening size O90 under EN ISO 12956
Geotextile Permeability Apparatus (Permittivity)
Constant and falling head apparatus for water flow normal to the plane of a geotextile, giving the permittivity figure a drainage or filtration layer is specified on.
IndentASTM D4491/D4491MDetermines: Permittivity in s⁻¹ and the flow rate through the fabric normal to its plane
Glass Bead Set and Separating Sieves for Apparent Opening Size
The graded glass beads and separating sieves that the dry-sieving apparent opening size method consumes — the part of an AOS rig that is bought again, not once.
IndentASTM D4751Purpose: Supplies and re-separates the graded spherical glass beads that ASTM D4751 Method A1 sieves through the specimen
Geotextile Abrasion Tester (Sliding Block)
Loaded sliding block that abrades a geotextile against abrasive paper for a set number of cycles, so the retained strength after installation damage can be measured.
IndentASTM D4886Determines: Retained strength after abrasion, as a percentage of the unabraded value
Thickness Gauge for Geotextiles and Geosynthetics
Dead-weight presser-foot gauge that reports geosynthetic thickness at a defined pressure — the figure every permittivity and transmissivity calculation is normalised against.
IndentASTM D5199Determines: Nominal thickness in millimetres, at a stated pressure
Micro, semi-micro and analytical balances, precision and table-top balances, platform scales and moisture analysers.
Micro Balance, 6.1 g x 0.001 mg, Touch Screen
Micro balance reading in 0.001 mg steps over a 6.1 g range, with motorised internal calibration and a double windshield, for weighing reference standards and sub-milligram samples.
IndentCapacity × readability: 6.1 g × 0.001 mg
Antistatic Ioniser for Balances, External and Windshield-Mounted
Bench ioniser that neutralises electrostatic charge on samples, containers and balance windshields, where static causes drifting and non-repeating readings on 0.01 and 0.1 mg balances.
IndentItem type: Accessory for micro, semi-micro and analytical balances; not a weighing instrument
Semi-Micro / Analytical Balance, Touch Screen, 102 g / 220 g
Dual-range semi-micro and analytical balance reading to 0.01 mg on the 102 g range and 0.1 mg on the 220 g range, with internal calibration, a 5-inch touch screen and a GLP database.
IndentCapacity × readability: 102 g × 0.01 mg (semi-micro range); 220 g × 0.1 mg (analytical range)
Semi-Micro / Analytical Balance, Touch Screen, 81 g / 220 g
Dual-range semi-micro and analytical balance reading to 0.01 mg on the 81 g range and 0.1 mg on the 220 g range, with internal calibration and an antistatic glass windshield.
IndentCapacity × readability: 81 g × 0.01 mg (semi-micro range); 220 g × 0.1 mg (analytical range)
Semi-Micro Balance, 61 g x 0.01 mg
Single-range semi-micro balance reading in 0.01 mg steps to 61 g, with internal calibration triggered by elapsed time and by temperature change, for laboratory and analytical weighing.
IndentCapacity × readability: 61 g × 0.01 mg
Semi-Micro / Analytical Balance, 82 g / 220 g
Dual-range semi-micro and analytical balance reading to 0.01 mg on the 82 g range and 0.1 mg on the 220 g range, supplied with an anti-vibration pad.
IndentCapacity × readability: 82 g × 0.01 mg (semi-micro range); 220 g × 0.1 mg (analytical range)
Balances, pH and conductivity meters, spectrophotometers, titration apparatus, extraction and digestion systems.
Analytical Balance, 220 g × 0.1 mg
Four-decimal analytical balance with draught shield and internal or external calibration.
Ex-stockISO/IEC 17025Capacity: 220 g
pH Meter, Benchtop, Five-Point Calibration
Microprocessor benchtop pH and mV meter with automatic temperature compensation and up to five-point calibration.
Ex-stockpH range: −2.00 to 16.00
UV-Visible Spectrophotometer, Double Beam
Double-beam UV-Vis spectrophotometer for quantitative absorbance and scanning work.
IndentUSP <857>Wavelength range: 190–1100 nm
Kjeldahl Digestion and Distillation Unit
Digestion block with fume scrubber and steam distillation unit for total nitrogen and crude protein determination.
IndentDigestion positions: 3, 6, 8 or 12
Conductivity / TDS Meter, Benchtop and Portable
Conductivity, TDS, salinity and resistivity measurement with automatic temperature compensation.
Ex-stockUSP <645>Conductivity range: 0.01 µS/cm to 200 mS/cm, auto-ranging
Automatic Potentiometric Titrator
Automatic titrator that follows the titration with an indicator electrode and locates the end point from the potential curve, for acid-base, redox, argentometric and non-aqueous determinations.
IndentTitration modes: DET (dynamic equivalence point), MET (monotone equivalence point), SET (preset end point), MAT (manual)
Tensile, elongation, hardness, abrasion, melt flow and impact testing for plastics, films, rubber compounds and moulded components.
HPLC and GC systems, autosamplers, column ovens, and the gas generators and vacuum pumps that support them.
High Performance Liquid Chromatography System, Isocratic and Binary Gradient
High performance liquid chromatograph supplied as an isocratic single-pump or binary gradient twin-pump system with a UV detector and a manual six-port injection valve.
IndentSystem, isocratic build / gradient build: Isocratic, one pump / binary gradient, two pumps working in parallel
Gas Chromatograph with Capillary Injector and Flame Ionisation Detector
Bench gas chromatograph with a capillary injector, a single flame ionisation detector and a column oven programmable to 400 °C, operated from a PC.
IndentSample introduction: Capillary injector, one fitted
Gas Chromatograph with Electronic Pneumatic Control, Split/Splitless Injector and FID
Bench gas chromatograph with electronic pneumatic control, a split and splitless injector and a flame ionisation detector, with a column oven programmable to 420 °C.
IndentPneumatics: EPC, electronic pneumatic control
Autosampler for Gas Chromatography, 22-Position Tray
Automatic liquid sampler that injects from a 22-position tray into a gas chromatograph, for unattended sequences and repeatable injection volumes.
IndentInjector sizes: 1, 5, 10, 25, 50, 100, 250, 500 (µl)
Air Generator, 2000 mL/min
Bench air generator that delivers dry compressed air at up to 2000 mL/min and 0.4 MPa, as a replacement for cylinder air on flame detectors and other laboratory air services.
IndentMaximum flow: 2000 mL/min
Hydrogen Generator, 99.999%, 300 mL/min
Electrolytic hydrogen generator delivering 99.999% hydrogen at up to 300 mL/min and 0.3 MPa, offered in an alkaline-electrolyte build and a pure-water build.
IndentGas purity: 99.999%
UV-visible and visible spectrophotometers, from single-beam teaching instruments to double-beam and PMT-detector research models.
Microvolume Spectrophotometer (Biophotometer)
Cuvette-free spectrophotometer that reads nucleic acid, protein, colorimetric and OD600 absorbance from a 0.5 to 2 µL drop placed directly on the sample pedestal.
IndentWavelength range: 190–850 nm
PMT Double-Beam UV-Visible Spectrophotometer with Mercury Lamp
Double-beam UV-visible spectrophotometer with a photomultiplier detector and a spectral bandwidth continuously adjustable from 0.1 to 5 nm, controlled from PC software.
IndentUSP <857>Beam configuration: Double beam, Czerny-Turner optics
Touchscreen Double-Beam UV-Visible Spectrophotometer
Double-beam UV-visible spectrophotometer with a 10-inch touchscreen and on-board data handling, offered with fixed or selectable spectral bandwidth and with a single or eight-position cell holder.
IndentUSP <857>Beam configuration: Double beam
Touchscreen Single-Beam UV-Visible Spectrophotometer
Single-beam UV-visible spectrophotometer with a 7-inch touchscreen, 2 nm spectral bandwidth and on-board data handling, for fixed-wavelength assay and routine scanning.
IndentUSP <857>Beam configuration: Single beam
Double-Beam UV-Visible Spectrophotometer, Dual Detector
Stand-alone double-beam UV-visible spectrophotometer whose two detectors read sample and reference at the same instant, offered with fixed or selectable bandwidth and a single or eight-position cell holder.
IndentUSP <857>Beam configuration: Double beam, 1200 lines/mm grating
Single-Beam UV-Visible Spectrophotometer, Numeric Keypad
Single-beam UV-visible spectrophotometer with 2 nm bandwidth and a numeric keypad, for standard-curve concentration work and routine fixed-wavelength assay.
IndentUSP <857>Beam configuration: Single beam, 1200 lines/mm grating
Viscometers, polarimeters, refractometers, density meters and melting point apparatus.
Automatic Density Meter, Oscillating U-Tube
Bench density meter that reads the density of a liquid from the resonant frequency of a vibrating quartz U-tube, on a sample of 2 to 3 mL.
IndentASTM D4052Measuring principle: Oscillating quartz glass U-tube with photoelectric detection
Melting Point Apparatus, Capillary, Touch Screen
Capillary melting point apparatus that heats the sample under PID control, records the melting curve and averages the initial and final melting points.
IndentUSP <741>Method: Capillary tube in a heated block
Automatic Video Melting Point Apparatus with CFR Software
Automatic melting point apparatus that measures four capillaries at once under a camera, with video playback and audit-trail software for regulated laboratories.
IndentUSP <741>Method: Capillary tube in a heated block, observed by camera
Automatic Polarimeter, Dual Wavelength, with CFR Software
Automatic polarimeter that reads optical rotation at 546 nm and 589 nm with Peltier control of the sample tube, and carries audit-trail and electronic-signature software.
IndentUSP <781>Measured quantity: Optical rotation, in degrees
Automatic Polarimeter, Single Wavelength, with CFR Software
Automatic polarimeter that reads optical rotation at 589 nm with Peltier control of the sample tube, and carries audit-trail and electronic-signature software.
IndentUSP <781>Measured quantity: Optical rotation, in degrees
Automatic Digital Polarimeter, Touch Screen, Without Temperature Control
Touch-screen digital polarimeter working on the optical-null principle with a Faraday modulator, in the two catalogue variants that display the sample temperature but do not hold it.
IndentMeasured quantity: Optical rotation, in degrees
Flash point, viscosity, distillation, pour and cloud point, penetration and density testing for fuels, oils, greases and bitumen.
Thermal cyclers, nucleic acid extraction, transilluminators, crosslinkers, hybridisation ovens and microplate instruments.
Blue Light Transilluminator, 470 nm
Blue-light gel viewer and cutting station for observing stained nucleic acid and protein bands in a gel, for photography or for excising a band.
IndentExcitation wavelength: 470 nm blue light
Nucleic Acid Extractor, 32 Samples (DNA and RNA)
Automated magnetic-bead workstation that lyses, binds, washes and elutes DNA or RNA from up to 32 samples in one unattended run.
IndentSamples per run: 1 to 32
Hybridisation Oven with Tube Rotation and Shaking Base
Hot-air convection oven that rotates hybridisation tubes at a held temperature for blot and membrane hybridisation, with a shaking platform in the base of the chamber.
IndentHeating: Hot air constant-temperature convection with an internal air circulation device
UV Crosslinker, 254 nm
Enclosed 254 nm ultraviolet chamber that fixes nucleic acid to hybridisation membranes under measured energy or timed control, and decontaminates PCR consumables.
IndentUV wavelength: 254 nm
ELISA Microplate Reader, 96-Well
Filter photometer that measures absorbance in 96-well microplates for enzyme-linked immunosorbent assays and other colorimetric endpoint assays.
IndentPlate format: 96-well microplates
Gradient PCR Thermal Cycler, 96-Well
Gradient thermal cycler for amplifying DNA and RNA, running a row of different annealing temperatures across the block so a primer pair can be optimised in one run.
IndentBlock format: 96-well, from the model designation and the 96-position plate layout shown on the instrument screen
Autoclaves, laminar air flow cabinets, BOD and bacteriological incubators, colony counters and aseptic handling equipment.
Vertical Autoclave, Fully Automatic
Triple-walled vertical steam steriliser with automatic cycle control, in standard and GMP specifications.
IndentISO 17665Operating condition: 121 °C at 15 psi (1.05 kg/cm²)
Laminar Air Flow Cabinet, Horizontal / Vertical
HEPA-filtered clean work station providing an ISO Class 5 work zone for aseptic handling.
IndentISO 14644-1Filtration: HEPA, 99.97% efficient at 0.3 µm
BOD Incubator, Digital
Refrigerated incubator with precise low-temperature control for biochemical oxygen demand and general culture work.
Ex-stockIS 3025 (Part 44)Temperature range: 5 °C to 50 °C
Orbital Shaking Incubator
Cabinet orbital shaker with heating and forced air circulation, offered in tray layouts from six 5-litre flasks to twenty-five 250 ml flasks, under PLC and touch-screen control.
IndentControl system: PLC with HMI touch screen
Programmable Vacuum Autoclave, Single-Lever Lock
Vertical steriliser with pre- and post-vacuum stages, so air is pulled out of wrapped and porous loads before steam enters and moisture is pulled out of them afterwards. PLC and HMI controlled.
IndentISO 17665Air removal: Pre-vacuum stage before steam admission
Stackable Incubator Shaker, 150 L, with or without CO2 Control
Floor-standing 150 L orbital incubator shaker for flask culture, stackable up to three separately controlled layers, offered as a heated unit and as a refrigerated unit with CO2 control.
IndentFunction, heated model / CO2 model: Heating & Cooling / CO2, Heating & Cooling (as printed)
Magnetic and overhead stirrers, hotplates, vortex and tube mixers, homogenisers, sonicators, ultrasonic cleaners, rotary evaporators and digestion systems.
Dispensing Peristaltic Pump, 0.005 to 641 mL/min
Tube-driven pump that meters and transfers liquid without the liquid ever touching the pump, for dispensing, feeding and quantitative transfer duties.
IndentFlow range: 0.005 to 641 mL/min
Rotary Evaporator, 1 L Flask, Motorised Lift
Motorised rotary evaporator that strips solvent from a 1 L flask under reduced pressure on a heated bath, with a vertical condenser and a separate collection bottle.
IndentEvaporation capacity (water): Max. 25 mL/min
Paddle Blender Homogeniser, 400 mL, Heated
Paddle blender that works the sample inside a closed sterile bag, so the initial suspension is prepared without any part of the machine touching the sample.
IndentISO 6887-1Working capacity: 4 mL to 400 mL
Hand-Held Rotor-Stator Homogeniser, 10 to 250 mL
Hand-held rotor-stator disperser that shears a 10 to 250 mL sample in the gap between a spinning rotor and a fixed stator, for homogenising, emulsifying and cell disruption.
IndentWorking capacity: 10 to 250 mL
Tissue Grinder Homogeniser (Bead Beater), 12 x 5 mL or 24 x 2 mL
Bead-beating tissue grinder that shakes closed tubes loaded with grinding balls to break plant, animal and microbial material into a uniform lysate for nucleic acid and protein work.
IndentTube holder, TGH12 / TGH24: 5 mL x 12 tubes / 2 mL x 24 tubes
Multi-Tube Vortex Mixer, 50 Tubes
Orbital vortex mixer that clamps a foam rack of tubes between two plates and mixes a whole batch at once, for extraction, resuspension and high-throughput mixing.
IndentMaximum tubes: 50, rack dependent
Hot air ovens, muffle and high-temperature furnaces, water baths, stability chambers and refrigerated equipment.
Muffle Furnace, 1200 °C
Programmable high-temperature muffle furnace for ashing, loss on ignition and heat treatment.
Ex-stockIS 4032Maximum temperature: 1200 °C (1400 °C on request)
Hot Air Oven, Digital, 250 °C
Forced-convection laboratory oven with stainless steel chamber for drying, moisture determination and dry-heat sterilisation.
Ex-stockIS 2720 (Part 2)Temperature range: Ambient +10 °C to 250 °C (300 °C on request)
Vacuum Oven, Laboratory, 27 Litres
Double-walled 27-litre vacuum oven with a mirror-polished stainless steel 316 chamber and PID control from 50 °C to 200 °C, for drying heat-sensitive materials at reduced pressure.
IndentTemperature range: 50 °C to 200 °C
Digital Water Bath, 2 / 4 / 6 / 8 Hole
Stainless steel digital water bath in four sizes from 6 to 24 litres, with 125 mm concentric-ring openings, PID control and a drain valve, for heating samples in beakers and flasks.
IndentNumber of holes, 2H / 4H / 6H / 8H: 2 / 4 / 6 / 8
Bursting strength, crush resistance, tear, Cobb sizing, grammage, drop, vibration, leak and seal testing for paper, corrugated board, film, foil and finished packaging.
Bursting Strength Tester
Hydraulic bursting strength tester that inflates a rubber diaphragm against a clamped specimen to measure the pressure at which paper, corrugated board, fabric or packaging material bursts.
IndentISO 2758Model type: Single head model, double head model
Box Compression Tester
Determines the compressive and stacking strength of corrugated boxes and cartons by applying a continuous load at a controlled rate until collapse.
IndentIS 7028 (Part VI)Capacity: 1000 Kgf (10 KN)
Paper Core and Tube Compression Tester
Measures radial, flat and vertical crush resistance of paper cores, paper tubes and paper cones used as winding carriers or as packing material.
IndentISO 3035Display: Standard Digital Model with backlit LCD display
Cobb Sizing Tester
Determines the water absorptiveness (Cobb value) of paper, paperboard and corrugated fibreboard over a specified time under standardised conditions.
IndentIS 1060Machine Body: Corrosion resistant main body
GSM Round Cutter for Paper and Fabric
Cuts an exact 100 cm² circular specimen from paper, board, film or fabric so that the specimen weight in grams multiplied by 100 gives grammage directly.
IndentASTM D3776Sample Area: 100 cm²
Scuff / Rub Proofness Tester
Assesses rub resistance and colour transfer of printed or coated paper, board, plastic film and aluminium foil under a standard rubbing load.
IndentBS 3110Power supply: 230 volts AC at 50 Hz (Fluctuation free power required)
COD and BOD apparatus, jar test flocculators, turbidity and dissolved oxygen measurement, and water quality analysers.
COD Digestion Apparatus with Glassware
Reflux digestion block with condensers and glassware for chemical oxygen demand determination.
Ex-stockIS 3025 (Part 58)Positions: 6 or 8
Jar Test Apparatus (Flocculator), Six Position
Six-paddle stirrer with synchronised speed control for optimising coagulant dose in water treatment.
Ex-stockASTM D2035Positions: 6
Total Organic Carbon Analyser, UV Oxidation with NDIR Detection
Total organic carbon analyser that oxidises the sample by UV and wet chemistry and measures the carbon dioxide released on a non-dispersive infrared detector, reporting TC, TIC, TOC and NPOC.
IndentDetection method: Wet chemical oxidation by UV
Total Organic Carbon Analyser, UV Oxidation with Conductivity Detection
Reagent-free TOC analyser for high-purity water that oxidises carbon with a UV lamp and measures the resulting conductivity change, in an offline model and an online/offline model.
IndentMode, offline model / online model: Offline / online (exclusive for lab), online and offline switchable
COD Analyser with 21-Position Digestor
Chemical oxygen demand analyser supplied with a 21-place digestor block, reading COD colorimetrically over two ranges after a two-hour dichromate digestion.
IndentMeasuring ranges: (15~150) mg/L, (150~1500) mg/L
BOD Analyser, Manometric, 6 Bottles
Six-place manometric BOD analyser that reads biochemical oxygen demand directly in mg/L from the pressure drop in sealed culture bottles during incubation.
IndentParameter: BOD
Stability chambers, humidity chambers, cooling chambers and BOD incubators, in cabinet and walk-in scale, for controlled temperature and relative humidity storage.
Humidity Chamber
Floor-standing double-walled chamber that holds a set temperature and relative humidity with PID control, used by pharmaceutical, chemical and electronics laboratories for controlled-environment storage and testing.
IndentTemperature measurement: By PID controller
Stability Chamber
Touch-screen PLC controlled temperature and humidity chamber that holds ICH storage conditions such as 25 °C/60 % RH and 40 °C/75 % RH, used by pharmaceutical QC and R&D laboratories for long-term and accelerated stability studies. Also printed as Humidity Chamber.
IndentStorage conditions fulfilled: 25 °C / 60 % RH; 30 °C / 65 % RH; 30 °C / 70 % RH; 30 °C / 75 % RH; 40 °C / 75 % RH; 25 °C / 40 % RH; 30 °C / 35 % RH; 40 °C / NMT 25 % RH
Walk-In Stability Chamber
Prefabricated modular walk-in room, 4,000 to 80,000 litres, that holds ICH temperature and humidity storage conditions for bulk pharmaceutical stability and retention samples under PLC touch-screen control.
IndentStorage conditions fulfilled: 25 °C / 60 % RH; 30 °C / 65 % RH; 30 °C / 70 % RH; 30 °C / 75 % RH; 40 °C / 75 % RH; 25 °C / 40 % RH; 30 °C / 35 % RH; 40 °C / NMT 25 % RH
Walk-In Cooling Chamber, 2–8 °C
Prefabricated modular walk-in cold room holding 2 °C to 8 °C, 4,000 to 80,000 litres, for bulk cold-chain storage of pharmaceuticals and biologicals with PLC touch-screen control and data logging.
IndentStorage conditions fulfilled: 2 °C to 8 °C
Cooling Chamber, 2–8 °C
Cabinet-style refrigerated chamber holding 2 °C to 8 °C in sizes from 92 to 1012 litres, for cold storage of pharmaceutical samples and reagents with PLC touch-screen control and audit-trail logging.
IndentStorage conditions fulfilled: 2 °C to 8 °C
Walk-In BOD Incubator
Prefabricated modular walk-in incubator operating from 5 °C to 60 °C, 4,000 to 80,000 litres, for bulk biochemical oxygen demand testing and microbiological incubation in water, food and pharma laboratories.
IndentStorage conditions fulfilled: 5 °C to 60 °C
Laboratory refrigerators, deep freezers and ultra-low temperature cabinets from +2 °C down to −80 °C, for samples, reagents and cultures.
Ultra-Low Temperature Deep Freezer, −40 °C to −80 °C
Upright ultra-low temperature freezer holding −40 °C to −80 °C on a cascade refrigeration system, with touch-screen control, alarms and Ethernet or PC connectivity for continuous temperature records.
IndentTemperature range: −40 °C to −80 °C
Twin-Chamber Laboratory Refrigerator and Deep Freezer
One cabinet carrying two independently controlled chambers, a 2 °C to 8 °C laboratory refrigerator and a 0 °C to −25 °C deep freezer, each with its own display and alarm.
IndentRefrigerator chamber: 2 °C to 8 °C
Refrigerated Circulating Bath, 10 L, Touchscreen
Refrigerated and heated circulating bath with internal and external pump circuits, for holding an instrument or a reaction at a set temperature between -30 °C and 100 °C.
IndentTemperature range, -10 / -20 / -30 model: -10°C to 100°C / -20°C to 100°C / -30°C to 100°C
Refrigerated Circulating Bath, 6 L, Horizontal, for Viscometer
Horizontal refrigerated circulating bath with a flat stainless top and a 110 mm circular opening, built so a rotational viscometer stand can work over the bath while the sample is held at temperature.
IndentShape: Horizontal (specialised for viscometer)
Recirculating Water Chiller, 3.5 L
Compact recirculating chiller that pumps temperature-controlled coolant to a condenser or jacket, replacing a running tap on a rotary evaporator or glass reactor.
IndentBath capacity: 3.5 L
Ice Maker, 15 kg per 24 h, Manual Fill
Bench-top bullet-ice maker producing about 15 kg of ice a day from a hand-filled reservoir, for cooling samples, buckets and reagent bottles at the bench.
IndentIce capacity: 15 kg / 24 h
Why we publish the standard revision, not just the number.
Testing instruments are bought against a method, and a method is written against a standard. When that standard is revised, the old number stays in circulation for years — sometimes decades — because catalogues copy each other and nobody re-checks.
Three examples currently live across this industry: ASTM D1559 for Marshall stability, withdrawn in 1998. ASTM D422 for hydrometer analysis, withdrawn in 2016. IS 13311 for non-destructive concrete testing, absorbed into the IS 516 family in 2018. All three still appear on product listings you can buy from today.
That matters commercially, not just pedantically. If your quality manual cites a withdrawn standard, a NABL assessor will raise it, and the fastest way that error enters a manual is by being copied off a supplier’s specification sheet.
On qualification: for pharmaceutical customers, the documentation is half the purchase. GMP-specification equipment differs in its contact surfaces, its control system, its printed cycle records and its IQ/OQ/PQ protocol set. Specify that requirement at enquiry stage — retrofitting it after installation costs more and delays qualification.
On site preparation: compression testing machines, ductility baths, abrasion machines and large ovens need foundations, three-phase supply, drainage or extraction. We issue the foundation drawing and utility schedule with the quotation so the civil work can run in parallel with the delivery lead time rather than after it.