Benchtop Dissolved Oxygen Meter, Polarographic
Benchtop dissolved oxygen meter with a polarographic membrane sensor reading concentration in mg/L or percent saturation, with salinity and barometric pressure correction.
Typical applications
- Effluent and BOD-related sampling
- Aquaculture and fish-farm water
- Surface and river water monitoring
- Fermentation and bioprocess sampling
- Boiler feed and process water
Add to enquiry
Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.
Worth knowing before you order
A polarographic sensor is a consumable assembly, not a solid-state probe: the membrane cap and the electrolyte are what actually wear out, and one of each is supplied. Keep spares, because a fouled or dried membrane reads low and gives no warning. Salinity and barometric pressure are corrected only after the operator types the values in — the meter does not sense either — so readings in brackish water or at altitude are only as good as the numbers entered. Calibration is in air (100%) or in zero-oxygen solution (0%); the zero-oxygen solution is not in the accessories list and is needed for the two-point routine.Specification
| Sensor type | Polarographic membrane electrode |
|---|---|
| Dissolved oxygen range | 0.00–20.00 mg/L or ppm |
| Dissolved oxygen resolution | 0.1 or 0.01 ppm, selectable |
| Dissolved oxygen accuracy | ± 0.2 mg/L or ppm |
| Oxygen saturation range | 0.0–200.0% |
| Saturation resolution / accuracy | 0.1 or 1%, selectable / ± 2.0% |
| Calibration | 1 or 2 points (100% in air, 0% in zero-oxygen solution) |
| Temperature range | 0.0–50.0 °C |
| Temperature accuracy | ± 0.5 °C |
| Temperature compensation | 0–50 °C / 32–122 °F, automatic |
| Salinity correction | 0–50 g/L |
| Barometric pressure correction | 60.0–112.5 kPa, 450–850 mmHg |
| Memory | 500 data sets with date and time |
| Display | LCD |
| Interface | USB |
| Connector | 6-pin mini-DIN |
| Stability setting | Low / high |
| Power supply | DC adaptor from AC 220 V, 50/60 Hz |
| Packing dimensions (L x W x H) | 310 x 250 x 190 mm |
| Gross weight | 2 kg |
Support available
- Installation & commissioning
- Calibration
- Operator training
- Annual maintenance contract
- Spares & consumables
Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.
Related products
Analytical Balance, 220 g × 0.1 mg
Four-decimal analytical balance with draught shield and internal or external calibration.
Ex-stockISO/IEC 17025Capacity: 220 g
Specification for Analytical Balance, 220 g × 0.1 mg
Specification for Analytical Balance, 220 g × 0.1 mg Capacity 220 g Readability 0.1 mg (0.0001 g) Repeatability ≤ 0.1 mg Linearity ± 0.2 mg Pan size 90 mm ø Calibration Internal motorised or external OIML class E2 weight Services Installation & commissioning · Calibration · Operator training · Annual maintenance contract Standards
ISO/IEC 17025Typical applications
- Weighing for standard and reagent preparation
- Gravimetric analysis
- Sample weighing for assay
Full record, hazard data and enquiry for Analytical Balance, 220 g × 0.1 mg →
pH Meter, Benchtop, Five-Point Calibration
Microprocessor benchtop pH and mV meter with automatic temperature compensation and up to five-point calibration.
Ex-stockpH range: −2.00 to 16.00
Specification for pH Meter, Benchtop, Five-Point Calibration
Specification for pH Meter, Benchtop, Five-Point Calibration pH range −2.00 to 16.00 pH resolution 0.01 (0.001 on selected models) Accuracy ± 0.01 pH Calibration points Up to 5, with auto buffer recognition Temperature ATC, −10 to 110 °C Output RS-232 / USB, optional printer Services Installation & commissioning · Calibration · Operator training · Annual maintenance contract · Spares & consumables Typical applications
- pH measurement in water, effluent and process samples
- Pharmaceutical QC pH determination
Full record, hazard data and enquiry for pH Meter, Benchtop, Five-Point Calibration →
UV-Visible Spectrophotometer, Double Beam
Double-beam UV-Vis spectrophotometer for quantitative absorbance and scanning work.
IndentUSP <857>Wavelength range: 190–1100 nm
Specification for UV-Visible Spectrophotometer, Double Beam
Specification for UV-Visible Spectrophotometer, Double Beam Wavelength range 190–1100 nm Spectral bandwidth 1 nm (2 nm and variable on selected models) Wavelength accuracy ± 0.3 nm Photometric range −0.3 to 3.0 A Stray light < 0.05% T at 220 nm Software PC control; 21 CFR Part 11 package to order Services Installation & commissioning · Calibration · Validation & qualification · Operator training · Annual maintenance contract · Spares & consumables Standards
USP <857>Typical applications
- Quantitative assay by absorbance
- COD, nitrate, phosphate and metals colorimetry
- Dissolution and content uniformity testing
Full record, hazard data and enquiry for UV-Visible Spectrophotometer, Double Beam →
Kjeldahl Digestion and Distillation Unit
Digestion block with fume scrubber and steam distillation unit for total nitrogen and crude protein determination.
IndentDigestion positions: 3, 6, 8 or 12
Specification for Kjeldahl Digestion and Distillation Unit
Specification for Kjeldahl Digestion and Distillation Unit Digestion positions 3, 6, 8 or 12 Digestion temperature Up to 450 °C, PID controlled Fume scrubber Water aspirator or recirculating, with neutralisation Distillation Steam generator with automatic alkali dosing Recovery ≥ 99.5% on ammonium sulphate reference Site preparation Required — foundation or utilities Services Installation & commissioning · Calibration · Operator training · Annual maintenance contract · Spares & consumables Typical applications
- Crude protein in food and feed
- Total Kjeldahl nitrogen in water and effluent
- Nitrogen in soil and fertiliser