Indent

Benchtop Ion / pH / mV Meter, Five-Point Calibration

Benchtop ion meter that reads ion concentration directly from an ion-selective electrode over two to five calibration points, and also measures pH, ORP and temperature.

Typical applications

  • Fluoride in drinking water and toothpaste
  • Nitrate in water, soils and fertilisers
  • Environmental monitoring
  • Food and pharmaceutical testing
  • pH and ORP measurement

Add to enquiry

Enquire on WhatsApp

Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.

Worth knowing before you order

The most important line in the accessories list is what is not in it: the meter ships with a pH electrode, stand, ATC probe and pH buffers, but no ion-selective electrode. The fluoride and nitrate ISEs are catalogued as optional accessories, and until one is fitted this is a pH and mV meter. Order the ISE, its standard solutions and its ionic strength adjustment buffer (TISAB or ISAB) at the same time — all three are consumables, and the ISE membrane has a service life that is shorter than the meter's by a wide margin. Ion calibration runs low concentration to high, over two to five points, so buy standards that bracket the concentration you expect.

Specification

Technical specification for Benchtop Ion / pH / mV Meter, Five-Point Calibration
ModesIon concentration, pH, mV / ORP, temperature
Ion concentration range0.001–19999 ppm, mg/L or mol/L, selectable, depending on the range of the ion-selective electrode
Ion concentration accuracy± 0.5% full scale (monovalent), ± 1% full scale (divalent)
Ion resolution0.001, 0.01, 0.1, 1
Ion calibrationUp to 5 points, low to high concentration
pH range / accuracy−2.000 to 20.000 pH / ± 0.002 pH
pH resolution0.001, 0.01, 0.1 pH, selectable
pH buffer setsUSA (1.68, 4.01, 7.00, 10.01, 12.45); NIST (1.68, 4.01, 6.86, 9.18, 12.45); DIN (1.09, 4.65, 6.79, 9.23, 12.7); or user defined
mV range / accuracy± 1999.9 mV / ± 0.2 mV
mV resolution0.1 or 1 mV, selectable
mV calibration1 point, relative mV mode only
Temperature range / accuracy0–105 °C, 32–221 °F / ± 0.5 °C
Temperature compensation0–100 °C, automatic or manual
Calibration due reminder1 to 31 days or off
Memory500 data sets with date and time
OutputUSB communication interface
Electrode connectorBNC
Power supplyDC adaptor from AC 220 V, 50/60 Hz
Packing dimensions (L x W x H)310 x 255 x 190 mm
Gross weight2 kg

Support available

  • Installation & commissioning
  • Calibration
  • Operator training
  • Annual maintenance contract
  • Spares & consumables

Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.