Benchtop Turbidity Meter with Total Suspended Solids Mode

Benchtop turbidity meter reading 1 to 2000 NTU from an 850 nm infrared source and a silicon photodiode, with a total suspended solids mode and up to seven-point formazin calibration.

Typical applications

  • Drinking water turbidity
  • Municipal water treatment monitoring
  • Industrial and municipal wastewater plants
  • Total suspended solids screening
  • Process and beverage water clarity

Add to enquiry

Enquire on WhatsApp

Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.

Worth knowing before you order

The catalogue prints the measuring principle for its portable turbidity meter as the nephelometric method at 90°, but for this bench model it gives only the 850 nm infrared source and the silicon photodiode detector and states no detection angle; if your method specifies a geometry or a source wavelength, get the angle confirmed in writing. No published turbidity method is cited anywhere on the page. Three formazin standards are supplied — 200, 500 and 1000 NTU — against seven available calibration points, so the 0.02, 10, 1500 and 2000 NTU standards are separate purchases; formazin standards have a shelf life and are a recurring cost. TSS is not measured independently: it is turbidity multiplied by a conversion factor you set from your own gravimetric work, so the ± 3% TSS accuracy applies to the conversion, not to the solids.

Specification

Technical specification for Benchtop Turbidity Meter with Total Suspended Solids Mode
Measurement range1–2000 NTU
Resolution0.01 (1–100 NTU), 0.1 (100–999 NTU), 1 (999–2000 NTU)
Accuracy± 5%
Turbidity unitsNTU, FNU, EBC, ASBC
Calibration2 to 7 points using formazin standards (0.02, 10.00, 200, 500, 1000, 1500, 2000 NTU)
Light sourceInfrared-emitting diode, 850 nm
DetectorSilicon photodiode
Stray light< 0.02 NTU
TSS rangeDepends on the TSS conversion factor set
TSS resolution / accuracy0.0 / 1; ± 3% of reading
Sample vials60 mm high x 25 mm diameter
MemoryUp to 200 data sets
Display4.5 in TFT
Password protectionYes
Operating temperature0–50 °C
Power requirementsDC adaptor from AC 220 V, 50/60 Hz
Packing dimensions (L x W x H)310 x 255 x 190 mm
Gross weight2 kg

Support available

  • Installation & commissioning
  • Calibration
  • Operator training
  • Annual maintenance contract
  • Spares & consumables

Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.