Glass Bead Sterilizer, 150 g Bead Charge
Bench-top glass bead sterilizer holding a 150 g bead charge at up to 300 °C, to decontaminate the working tips of forceps, scissors, scalpels and loops in about ten seconds.
Typical applications
- Sterilising forceps, scissors and scalpel tips between uses
- Sterilising inoculation loops and needles
- Flame-free working at the bench or in a cabinet
- Small-animal and surgical instrument tip decontamination
Add to enquiry
Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.
Worth knowing before you order
It sterilises only what goes into the beads. The well is 40 x 80 mm, so the working end of an instrument is treated and the shaft, hinge and handle above the bead line are not - which is fine for a loop or a scalpel tip and wrong for anything that must be sterile along its whole length. It is not an autoclave substitute: no wrapped loads, no media, no liquids, no packaging, no cycle record, and a few seconds of dry heat at 250-300 °C is not the validated equivalent of 121 °C for 15 minutes of saturated steam. Allow the ≤25 min warm-up before the first use of the day. The beads themselves are a consumable and are not listed among the standard accessories, so ask whether the first 150 g charge is included and budget for replacements.Specification
| Capacity of glass beads | 150 g |
|---|---|
| Glass beads sterilization time | 10 seconds |
| Container dimensions | 40 x 80 mm |
| Temperature range | 100°C ~ 300°C |
| Time to reach maximum temperature | ≤25 min |
| Temperature control accuracy | ≤ ±5°C |
| Display | Digital temperature display with indicator light |
| Power supply | AC 220V / 50-60Hz |
| Packing dimension (L x W x H) | 160 x 130 x 185 mm |
| Gross weight (approx.) | 3 kg |
Support available
- Installation & commissioning
- Operator training
- Spares & consumables
Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.
Related products
Vertical Autoclave, Fully Automatic
Triple-walled vertical steam steriliser with automatic cycle control, in standard and GMP specifications.
IndentISO 17665Operating condition: 121 °C at 15 psi (1.05 kg/cm²)
Specification for Vertical Autoclave, Fully Automatic
Specification for Vertical Autoclave, Fully Automatic Operating condition 121 °C at 15 psi (1.05 kg/cm²) Chamber volumes 35 L, 53 L, 78 L, 95 L, 119 L and 178 L Construction Stainless steel 304 chamber; 316 on GMP models Safety Spring-loaded safety valve, pressure switch, vacuum breaker Control PLC with HMI, cycle printout on GMP models Documentation IQ / OQ / PQ protocols available Site preparation Required — foundation or utilities Services Installation & commissioning · Calibration · Validation & qualification · Operator training · Annual maintenance contract · Spares & consumables Standards
ISO 17665Typical applications
- Sterilisation of culture media and glassware
- Decontamination of biological waste
- Pharmaceutical and hospital sterilisation
Full record, hazard data and enquiry for Vertical Autoclave, Fully Automatic →
Laminar Air Flow Cabinet, Horizontal / Vertical
HEPA-filtered clean work station providing an ISO Class 5 work zone for aseptic handling.
IndentISO 14644-1Filtration: HEPA, 99.97% efficient at 0.3 µm
Specification for Laminar Air Flow Cabinet, Horizontal / Vertical
Specification for Laminar Air Flow Cabinet, Horizontal / Vertical Filtration HEPA, 99.97% efficient at 0.3 µm Pre-filter Washable synthetic, 5 µm Air velocity 0.45 ± 0.1 m/s at the work surface Work zone class ISO Class 5 Sizes 2 ft, 3 ft, 4 ft and 6 ft Fitted with UV germicidal lamp, fluorescent lamp, manometer Services Installation & commissioning · Validation & qualification · Operator training · Annual maintenance contract · Spares & consumables Standards
ISO 14644-1Typical applications
- Aseptic media pouring and plating
- Plant tissue culture
- Sterile sample preparation
Full record, hazard data and enquiry for Laminar Air Flow Cabinet, Horizontal / Vertical →
BOD Incubator, Digital
Refrigerated incubator with precise low-temperature control for biochemical oxygen demand and general culture work.
Ex-stockIS 3025 (Part 44)Temperature range: 5 °C to 50 °C
Specification for BOD Incubator, Digital
Specification for BOD Incubator, Digital Temperature range 5 °C to 50 °C Accuracy ± 0.5 °C Chamber volumes 110 L, 170 L, 216 L and 336 L Construction Stainless steel inner, PUF insulated Control Digital PID with safety thermostat Options Data logger, chart recorder, GMP dual chamber Services Installation & commissioning · Calibration · Validation & qualification · Annual maintenance contract · Spares & consumables Standards
IS 3025 (Part 44)Typical applications
- BOD₅ determination at 20 °C
- Bacteriological culture at controlled temperature
- Seed and germination studies
Full record, hazard data and enquiry for BOD Incubator, Digital →
Orbital Shaking Incubator
Cabinet orbital shaker with heating and forced air circulation, offered in tray layouts from six 5-litre flasks to twenty-five 250 ml flasks, under PLC and touch-screen control.
IndentControl system: PLC with HMI touch screen
Specification for Orbital Shaking Incubator
Specification for Orbital Shaking Incubator Control system PLC with HMI touch screen Temperature control High precision, with forced air circulation for uniformity Interior Stainless steel 304 Illumination LED lighting, dimmable Timer Automatic 24-hour cyclic timer PC software Compatible with 21 CFR Part 11 compliance PC software Flask capacity 5000 ml 6 flasks Flask capacity 2000 ml 16 flasks Flask capacity 1000 ml 9 or 4 flasks Flask capacity 500 ml 25 or 16 flasks Flask capacity 250 ml 25, 16 or 9 flasks Services Validation & qualification Typical applications
- Shaken flask culture in conical flasks
- Temperature-controlled incubation with continuous agitation
Full record, hazard data and enquiry for Orbital Shaking Incubator →