Vertical Autoclave, Fully Automatic
Triple-walled vertical steam steriliser with automatic cycle control, in standard and GMP specifications.
Typical applications
- Sterilisation of culture media and glassware
- Decontamination of biological waste
- Pharmaceutical and hospital sterilisation
Conforms to
- ISO 17665—Sterilization of health care products — Moist heat — Requirements for the development, validation and routine control of a sterilization process for medical devices
Add to enquiry
Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.
Worth knowing before you order
GMP and non-GMP models look similar and price very differently. The GMP specification buys 316 contact surfaces, a validated PLC, printed cycle records and a qualification documentation set. If your customer or auditor expects chamber mapping and recovery studies, you need the GMP model — say so at enquiry.Specification
| Operating condition | 121 °C at 15 psi (1.05 kg/cm²) |
|---|---|
| Chamber volumes | 35 L, 53 L, 78 L, 95 L, 119 L and 178 L |
| Construction | Stainless steel 304 chamber; 316 on GMP models |
| Safety | Spring-loaded safety valve, pressure switch, vacuum breaker |
| Control | PLC with HMI, cycle printout on GMP models |
| Documentation | IQ / OQ / PQ protocols available |
Site preparation required
This instrument needs site work before delivery — typically a level grouted foundation, a dedicated power supply, and in some cases drainage or extraction. We issue the foundation drawing and utility schedule with the quotation so the civil work runs in parallel with the lead time.Support available
- Installation & commissioning
- Calibration
- Validation & qualification (IQ/OQ/PQ)
- Operator training
- Annual maintenance contract
- Spares & consumables
Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.
Related products
Laminar Air Flow Cabinet, Horizontal / Vertical
HEPA-filtered clean work station providing an ISO Class 5 work zone for aseptic handling.
IndentISO 14644-1Filtration: HEPA, 99.97% efficient at 0.3 µm
Specification for Laminar Air Flow Cabinet, Horizontal / Vertical
Specification for Laminar Air Flow Cabinet, Horizontal / Vertical Filtration HEPA, 99.97% efficient at 0.3 µm Pre-filter Washable synthetic, 5 µm Air velocity 0.45 ± 0.1 m/s at the work surface Work zone class ISO Class 5 Sizes 2 ft, 3 ft, 4 ft and 6 ft Fitted with UV germicidal lamp, fluorescent lamp, manometer Services Installation & commissioning · Validation & qualification · Operator training · Annual maintenance contract · Spares & consumables Standards
ISO 14644-1Typical applications
- Aseptic media pouring and plating
- Plant tissue culture
- Sterile sample preparation
Full record, hazard data and enquiry for Laminar Air Flow Cabinet, Horizontal / Vertical →
BOD Incubator, Digital
Refrigerated incubator with precise low-temperature control for biochemical oxygen demand and general culture work.
Ex-stockIS 3025 (Part 44)Temperature range: 5 °C to 50 °C
Specification for BOD Incubator, Digital
Specification for BOD Incubator, Digital Temperature range 5 °C to 50 °C Accuracy ± 0.5 °C Chamber volumes 110 L, 170 L, 216 L and 336 L Construction Stainless steel inner, PUF insulated Control Digital PID with safety thermostat Options Data logger, chart recorder, GMP dual chamber Services Installation & commissioning · Calibration · Validation & qualification · Annual maintenance contract · Spares & consumables Standards
IS 3025 (Part 44)Typical applications
- BOD₅ determination at 20 °C
- Bacteriological culture at controlled temperature
- Seed and germination studies
Full record, hazard data and enquiry for BOD Incubator, Digital →
Orbital Shaking Incubator
Cabinet orbital shaker with heating and forced air circulation, offered in tray layouts from six 5-litre flasks to twenty-five 250 ml flasks, under PLC and touch-screen control.
IndentControl system: PLC with HMI touch screen
Specification for Orbital Shaking Incubator
Specification for Orbital Shaking Incubator Control system PLC with HMI touch screen Temperature control High precision, with forced air circulation for uniformity Interior Stainless steel 304 Illumination LED lighting, dimmable Timer Automatic 24-hour cyclic timer PC software Compatible with 21 CFR Part 11 compliance PC software Flask capacity 5000 ml 6 flasks Flask capacity 2000 ml 16 flasks Flask capacity 1000 ml 9 or 4 flasks Flask capacity 500 ml 25 or 16 flasks Flask capacity 250 ml 25, 16 or 9 flasks Services Validation & qualification Typical applications
- Shaken flask culture in conical flasks
- Temperature-controlled incubation with continuous agitation
Full record, hazard data and enquiry for Orbital Shaking Incubator →
Programmable Vacuum Autoclave, Single-Lever Lock
Vertical steriliser with pre- and post-vacuum stages, so air is pulled out of wrapped and porous loads before steam enters and moisture is pulled out of them afterwards. PLC and HMI controlled.
IndentISO 17665Air removal: Pre-vacuum stage before steam admission
Specification for Programmable Vacuum Autoclave, Single-Lever Lock
Specification for Programmable Vacuum Autoclave, Single-Lever Lock Air removal Pre-vacuum stage before steam admission Load drying Post-vacuum stage after the sterilising hold Temperature range 105 °C to 135 °C, programmable Lid Single-lever locking mechanism Control PLC with HMI touch screen, programmable cycles Connectivity Ethernet communication PC software 21 CFR Part 11 capable data-acquisition software Safety cutoffs Low temperature cutoff; low water level cutoff Site preparation Required — foundation or utilities Services Installation & commissioning · Calibration · Validation & qualification · Operator training · Annual maintenance contract · Spares & consumables Standards
ISO 17665Typical applications
- Sterilisation of wrapped instruments and porous loads
- Sterilisation of tubing, filters and hollow items
- Culture media and glassware sterilisation
- Decontamination of biological waste
Full record, hazard data and enquiry for Programmable Vacuum Autoclave, Single-Lever Lock →