Ice Flaker, Touchscreen, 200 kg per 24 h, Detachable Bin
Floor-standing flake ice machine rated at 200 kg a day over a detachable 60 kg bin, for departments that draw ice by the bucket rather than by the scoop.
Typical applications
- Bulk ice supply for sample transport and storage
- Packing specimens and tissue in ice
- Ice baths for extraction and homogenisation
- Hospital, research institute and biotechnology laboratory supply
Add to enquiry
Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.
Worth knowing before you order
This is the bulk machine in the range: 200 kg a day over a 60 kg bin, sized for a department rather than a bench. The bin detaches, which matters more than it sounds - it is how the machine is cleaned and how it gets through a doorway, and the two parts are shipped and weighed separately at 66 kg and 35 kg. It is a plumbed installation: 25 mm water supply, drainage tube, a water filter in the standard kit, and front and back ventilation clearance with ambient below 25 °C. Flake ice packs around samples and cools by contact, which cube ice does not. One gap to close before siting - the table prints input power (850 W) but no mains voltage or frequency for this model, so confirm the electrical supply in writing. Refrigerant is R290A, which is flammable.Specification
| Capacity | 200 kg per 24 hours |
|---|---|
| Storage capacity | 60 kg |
| Ice type | Flake ice, continuous output |
| Storage bin | ABS, detachable |
| Cooling method | Compressor cooling with fan cooling, front and back ventilation |
| Ambient temperature | Below 25°C for optimum working |
| Water temperature (recommended) | 20°C |
| Water supply size | 25 mm |
| Construction material | Stainless steel |
| Noise level | 58 db |
| Refrigerant | R290A, CFC free compressor |
| Display and control | Touch screen, fully automatic microprocessor control, timer function |
| Auto off | Yes |
| Low water level indication | Yes |
| Input power | 850 W |
| Packing dimension (L x W x H) | 755 x 655 x 640 mm |
| Gross weight (main instrument + storage bin) | 66 kg + 35 kg |
| Supplied with | Water filter with inlet and outlet tube, inlet tube, drainage tube, ice shovel (scoop), leg, instruction manual, test certificate |
Site preparation required
This instrument needs site work before delivery — typically a level grouted foundation, a dedicated power supply, and in some cases drainage or extraction. We issue the foundation drawing and utility schedule with the quotation so the civil work runs in parallel with the lead time.Support available
- Installation & commissioning
- Operator training
- Annual maintenance contract
- Spares & consumables
Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.
Related products
Ultra-Low Temperature Deep Freezer, −40 °C to −80 °C
Upright ultra-low temperature freezer holding −40 °C to −80 °C on a cascade refrigeration system, with touch-screen control, alarms and Ethernet or PC connectivity for continuous temperature records.
IndentTemperature range: −40 °C to −80 °C
Specification for Ultra-Low Temperature Deep Freezer, −40 °C to −80 °C
Specification for Ultra-Low Temperature Deep Freezer, −40 °C to −80 °C Temperature range −40 °C to −80 °C Refrigeration Cascade refrigeration system Refrigerant CFC free Control and display Touch screen Alarm Fitted, with e-mail alert Connectivity Ethernet communication and PC connectivity Safety provisions Over-temperature cut-off; electrical overload cut-off; time delay for compressor switch-on Qualification documents IQ / OQ / PQ documents available Services Validation & qualification Typical applications
- Ultra-low temperature storage of laboratory samples
- Storage of biological material and reagents below −40 °C
Full record, hazard data and enquiry for Ultra-Low Temperature Deep Freezer, −40 °C to −80 °C →
Twin-Chamber Laboratory Refrigerator and Deep Freezer
One cabinet carrying two independently controlled chambers, a 2 °C to 8 °C laboratory refrigerator and a 0 °C to −25 °C deep freezer, each with its own display and alarm.
IndentRefrigerator chamber: 2 °C to 8 °C
Specification for Twin-Chamber Laboratory Refrigerator and Deep Freezer
Specification for Twin-Chamber Laboratory Refrigerator and Deep Freezer Refrigerator chamber 2 °C to 8 °C Deep freezer chamber 0 °C to −25 °C Refrigeration Cascade refrigeration system Refrigerant CFC free Control and display Touch screen, with a display on each chamber Alarm Fitted, with e-mail alert Connectivity Ethernet communication and PC connectivity Safety provisions Over-temperature cut-off; electrical overload cut-off; time delay for compressor switch-on Qualification documents IQ / OQ / PQ documents available Services Validation & qualification Typical applications
- Cold storage of reagents and samples at 2-8 °C
- Frozen storage down to −25 °C
- Laboratories needing both duties in one footprint
Full record, hazard data and enquiry for Twin-Chamber Laboratory Refrigerator and Deep Freezer →
Refrigerated Circulating Bath, 10 L, Touchscreen
Refrigerated and heated circulating bath with internal and external pump circuits, for holding an instrument or a reaction at a set temperature between -30 °C and 100 °C.
IndentTemperature range, -10 / -20 / -30 model: -10°C to 100°C / -20°C to 100°C / -30°C to 100°C
Specification for Refrigerated Circulating Bath, 10 L, Touchscreen
Specification for Refrigerated Circulating Bath, 10 L, Touchscreen Temperature range, -10 / -20 / -30 model -10°C to 100°C / -20°C to 100°C / -30°C to 100°C Temperature display resolution 0.01°C Temperature accuracy ±0.05°C Temperature control Microprocessor PID, programmable controller Temperature sensor PT100 Display Touchscreen Refrigeration Air cooled refrigeration through compressor Refrigerant R-134A Pump circulation Internal and external Pump flow rate 8 L/min Bath tank capacity 10 L Tank size (L x W x D) 270 x 200 x 200 mm 9 further specifications on the full record.
Typical applications
- Jacketing a rotary evaporator or glass reactor
- Temperature control of spectrophotometer and polarimeter cells
- Viscometer and refractometer sample conditioning
- Fermentation tank and chromatographic column temperature control
- Electrophoresis cooling
Also known as
- Refrigerated circulator
- Chiller bath
- Low temperature circulating bath
- Heating and cooling circulator
- Thermostatic bath
Full record, hazard data and enquiry for Refrigerated Circulating Bath, 10 L, Touchscreen →
Refrigerated Circulating Bath, 6 L, Horizontal, for Viscometer
Horizontal refrigerated circulating bath with a flat stainless top and a 110 mm circular opening, built so a rotational viscometer stand can work over the bath while the sample is held at temperature.
IndentShape: Horizontal (specialised for viscometer)
Specification for Refrigerated Circulating Bath, 6 L, Horizontal, for Viscometer
Specification for Refrigerated Circulating Bath, 6 L, Horizontal, for Viscometer Shape Horizontal (specialised for viscometer) Temperature range -20°C to 100°C Temperature display resolution 0.01°C Temperature accuracy ± 0.05°C Temperature control Microprocessor PID, programmable controller Temperature sensor PT100 Display Touchscreen Refrigeration Air cooled refrigeration through compressor Refrigerant R-134A Pump circulation Internal and external Pump flow rate 6 L/min Bath tank capacity 6 L 9 further specifications on the full record.
Typical applications
- Sample conditioning under a rotational viscometer
- Spectrophotometer and polarimeter cell temperature control
- Refractometer sample conditioning
- Fermentation tank and chromatographic column temperature control
Also known as
- Viscometer bath
- Horizontal refrigerated circulator
- Low temperature bath for viscometer
- Refrigerated circulator, flat top