Ice Flaker, Touchscreen, 30 / 50 / 100 kg per 24 h
Plumbed flake ice machine in three daily outputs, producing dry flakes that pack around samples and cool them by contact rather than sitting beside them as cubes do.
Typical applications
- Packing samples and specimens in ice
- Cooling flasks, bags and tissue during preparation
- Ice baths for homogenisation and extraction
- Hospital, research institute and biotechnology laboratory supply
Add to enquiry
Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.
Worth knowing before you order
Flake ice is the reason to choose this over a cube machine. Soft, dry flakes pack around a flask, a bag or a specimen and cool over the whole contact surface, so a sample chills faster and holds temperature longer than it does propped in cube ice. Two practical points. First, this is a plumbed installation, not a bench appliance: it needs a 3/4 inch BSP water supply and a drain, and front and back ventilation clearance. Second, size on the storage bin, not on the headline output - 12, 16 or 35 kg of storage against 30, 50 or 100 kg per 24 h, so what matters is how much ice you draw at once, not the daily total. Rated output assumes ambient below 25 °C. Refrigerant is R290A, which is propane and therefore flammable.Specification
| Capacity of ice flake (kg per 24 hrs), 30 / 50 / 100 model | 30 kg / 50 kg / 100 kg |
|---|---|
| Storage capacity (approx.), 30 / 50 / 100 model | 12 kg / 16 kg / 35 kg |
| Ice type | Flake ice, continuous output |
| Storage bin material | ABS plastic |
| Cooling method | Air, front and back ventilation design |
| Ambient temperature | Below 25°C for optimum working |
| Construction | Stainless steel, SS304 |
| Noise level | ≤52 dB |
| Water supply | 3/4 inch BSP |
| Refrigerant | R290A, CFC free compressor |
| Control and display | Fully automatic microprocessor control, touchscreen with timer and temperature function |
| Protection indications | Compressor overload, motor overload, water shortage, high pressure, low pressure, temperature protection, missing phase, wrong phase, current unbalance |
| Low water level indication | Yes |
| Input power, 30 / 50 / 100 model | 180 W / 280 W / 420 W |
| Power supply | AC 220V, 50/60Hz |
| Packing dimension (L x W x H) | 610 x 470 x 780 mm / 610 x 470 x 820 mm / 690 x 550 x 900 mm |
| Gross weight, 30 / 50 / 100 model | 51 kg / 52 kg / 74 kg |
| Supplied with | Inlet tube, drainage tube, ice shovel (scoop), instruction manual, test certificate |
Site preparation required
This instrument needs site work before delivery — typically a level grouted foundation, a dedicated power supply, and in some cases drainage or extraction. We issue the foundation drawing and utility schedule with the quotation so the civil work runs in parallel with the lead time.Support available
- Installation & commissioning
- Operator training
- Annual maintenance contract
- Spares & consumables
Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.
Related products
Ultra-Low Temperature Deep Freezer, −40 °C to −80 °C
Upright ultra-low temperature freezer holding −40 °C to −80 °C on a cascade refrigeration system, with touch-screen control, alarms and Ethernet or PC connectivity for continuous temperature records.
IndentTemperature range: −40 °C to −80 °C
Specification for Ultra-Low Temperature Deep Freezer, −40 °C to −80 °C
Specification for Ultra-Low Temperature Deep Freezer, −40 °C to −80 °C Temperature range −40 °C to −80 °C Refrigeration Cascade refrigeration system Refrigerant CFC free Control and display Touch screen Alarm Fitted, with e-mail alert Connectivity Ethernet communication and PC connectivity Safety provisions Over-temperature cut-off; electrical overload cut-off; time delay for compressor switch-on Qualification documents IQ / OQ / PQ documents available Services Validation & qualification Typical applications
- Ultra-low temperature storage of laboratory samples
- Storage of biological material and reagents below −40 °C
Full record, hazard data and enquiry for Ultra-Low Temperature Deep Freezer, −40 °C to −80 °C →
Twin-Chamber Laboratory Refrigerator and Deep Freezer
One cabinet carrying two independently controlled chambers, a 2 °C to 8 °C laboratory refrigerator and a 0 °C to −25 °C deep freezer, each with its own display and alarm.
IndentRefrigerator chamber: 2 °C to 8 °C
Specification for Twin-Chamber Laboratory Refrigerator and Deep Freezer
Specification for Twin-Chamber Laboratory Refrigerator and Deep Freezer Refrigerator chamber 2 °C to 8 °C Deep freezer chamber 0 °C to −25 °C Refrigeration Cascade refrigeration system Refrigerant CFC free Control and display Touch screen, with a display on each chamber Alarm Fitted, with e-mail alert Connectivity Ethernet communication and PC connectivity Safety provisions Over-temperature cut-off; electrical overload cut-off; time delay for compressor switch-on Qualification documents IQ / OQ / PQ documents available Services Validation & qualification Typical applications
- Cold storage of reagents and samples at 2-8 °C
- Frozen storage down to −25 °C
- Laboratories needing both duties in one footprint
Full record, hazard data and enquiry for Twin-Chamber Laboratory Refrigerator and Deep Freezer →
Refrigerated Circulating Bath, 10 L, Touchscreen
Refrigerated and heated circulating bath with internal and external pump circuits, for holding an instrument or a reaction at a set temperature between -30 °C and 100 °C.
IndentTemperature range, -10 / -20 / -30 model: -10°C to 100°C / -20°C to 100°C / -30°C to 100°C
Specification for Refrigerated Circulating Bath, 10 L, Touchscreen
Specification for Refrigerated Circulating Bath, 10 L, Touchscreen Temperature range, -10 / -20 / -30 model -10°C to 100°C / -20°C to 100°C / -30°C to 100°C Temperature display resolution 0.01°C Temperature accuracy ±0.05°C Temperature control Microprocessor PID, programmable controller Temperature sensor PT100 Display Touchscreen Refrigeration Air cooled refrigeration through compressor Refrigerant R-134A Pump circulation Internal and external Pump flow rate 8 L/min Bath tank capacity 10 L Tank size (L x W x D) 270 x 200 x 200 mm 9 further specifications on the full record.
Typical applications
- Jacketing a rotary evaporator or glass reactor
- Temperature control of spectrophotometer and polarimeter cells
- Viscometer and refractometer sample conditioning
- Fermentation tank and chromatographic column temperature control
- Electrophoresis cooling
Also known as
- Refrigerated circulator
- Chiller bath
- Low temperature circulating bath
- Heating and cooling circulator
- Thermostatic bath
Full record, hazard data and enquiry for Refrigerated Circulating Bath, 10 L, Touchscreen →
Refrigerated Circulating Bath, 6 L, Horizontal, for Viscometer
Horizontal refrigerated circulating bath with a flat stainless top and a 110 mm circular opening, built so a rotational viscometer stand can work over the bath while the sample is held at temperature.
IndentShape: Horizontal (specialised for viscometer)
Specification for Refrigerated Circulating Bath, 6 L, Horizontal, for Viscometer
Specification for Refrigerated Circulating Bath, 6 L, Horizontal, for Viscometer Shape Horizontal (specialised for viscometer) Temperature range -20°C to 100°C Temperature display resolution 0.01°C Temperature accuracy ± 0.05°C Temperature control Microprocessor PID, programmable controller Temperature sensor PT100 Display Touchscreen Refrigeration Air cooled refrigeration through compressor Refrigerant R-134A Pump circulation Internal and external Pump flow rate 6 L/min Bath tank capacity 6 L 9 further specifications on the full record.
Typical applications
- Sample conditioning under a rotational viscometer
- Spectrophotometer and polarimeter cell temperature control
- Refractometer sample conditioning
- Fermentation tank and chromatographic column temperature control
Also known as
- Viscometer bath
- Horizontal refrigerated circulator
- Low temperature bath for viscometer
- Refrigerated circulator, flat top