Ion-Selective Electrodes, Fluoride and Nitrate (Combination)

Refillable combination ion-selective electrodes for fluoride and for nitrate, supplied as replacement sensors for any ion meter fitted with a BNC socket.

Typical applications

  • Fluoride in drinking water, waste water and sea water
  • Fluoride in toothpaste, foods and biological fluids
  • Nitrate in pollution testing and fertilisers
  • Nitrate in foods, meats and pickling baths
  • Nitrate in pharmaceuticals and explosives testing

Add to enquiry

Enquire on WhatsApp

Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.

Worth knowing before you order

These are consumable sensors, not instruments: both are refillable combination electrodes with a finite membrane life, and the internal filling solution, the standard solutions and the ionic strength adjustment buffer supplied with them are all recurring purchases. Each has a narrow working pH window — 5 to 7 for fluoride, 2.5 to 11 for nitrate — which is exactly why TISAB (fluoride) and ISAB (nitrate) are in the box; sample and standard must both be conditioned or the calibration is meaningless. The catalogue also carries a specific instruction for the fluoride electrode: use plastic containers only for the analysis. Two conflicting dimension rows are printed for each electrode (186 x 65 x 80 mm and 185 x 65 x 50 mm), so no overall dimensions are reproduced here.

Specification

Technical specification for Ion-Selective Electrodes, Fluoride and Nitrate (Combination)
Item typeReplacement / consumable ion-selective electrodes, sold as sensors not as instruments
Fluoride electrode (ISE19), ionFluoride, F⁻
Fluoride electrode, concentration range10⁻¹ M to 10⁻⁵ M (1900 ppm to 0.2 ppm)
Fluoride electrode, pH window5 to 7 pH
Fluoride electrode, membraneSolid state
Fluoride electrode, main interferenceOH⁻
Fluoride electrode, reproducibility± 2%
Fluoride electrode, supplied withFluoride standard solution 500 ml, TISAB 500 ml, internal filling solution 30 ml
Nitrate electrode (ISE62), ionNitrate, NO₃⁻
Nitrate electrode, concentration range10⁻¹ M to 10⁻⁴ M (6200 ppm to 6.2 ppm)
Nitrate electrode, pH window2.5 to 11 pH
Nitrate electrode, membranePVC
Nitrate electrode, main interferencesClO₄⁻, I⁻, BF₄⁻
Nitrate electrode, reproducibility± 4%
Nitrate electrode, supplied withNitrate standard solution 500 ml, ISAB 500 ml, internal filling solution 30 ml
Both electrodes, body and typePlastic body, combination, refillable
Both electrodes, temperature range5 to 60 °C
Both electrodes, resistance< 1 MΩ
Both electrodes, slope−52 to −60 mV
Both electrodes, cable and connector1 metre cable, BNC
CompatibilityUsable with other makes of ion meter having a BNC socket

Support available

  • Calibration
  • Spares & consumables

Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.