Indent

Portable Dissolved Oxygen Meter, Polarographic

Battery-powered portable dissolved oxygen meter with a polarographic membrane electrode, reading mg/L or percent saturation with manual salinity and pressure correction.

Typical applications

  • River, lake and reservoir surveys
  • Aquaculture and fish-pond monitoring
  • Effluent discharge checks
  • Sewage treatment aeration control
  • Field water quality work

Add to enquiry

Enquire on WhatsApp

Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.

Worth knowing before you order

The figure that decides between this and the bench dissolved oxygen meter is accuracy: this portable is specified at ± 0.5 mg/L, the bench model at ± 0.2 mg/L, so a compliance limit near the meter's uncertainty belongs on the bench instrument. The polarographic electrode is a consumable assembly — one membrane cap and one bottle of electrolyte are supplied, and both are re-ordered routinely; a damaged membrane reads low without any obvious symptom. Salinity and barometric pressure are corrected only from values the operator enters by hand, which matters in brackish water and at altitude. Zero-oxygen solution for the two-point calibration is not listed among the accessories.

Specification

Technical specification for Portable Dissolved Oxygen Meter, Polarographic
Sensor typePolarographic dissolved oxygen electrode
Dissolved oxygen range0.00 to 20.00 mg/L (ppm)
Dissolved oxygen resolution0.01 mg/L (ppm)
Dissolved oxygen accuracy± 0.5 mg/L (ppm)
Saturation range0.0 to 200.0%
Saturation resolution / accuracy0.1% / ± 2.0%
Calibration1 or 2 points (air-saturated water or zero-oxygen solution)
Temperature compensation0 to 50 °C / 32 to 122 °F, automatic
Pressure correction60.0 to 113.3 kPa / 450 to 850 mmHg, manual
Salinity correction0.0 to 50.0 ppt, manual
DisplayLCD, backlit
Hold functionManual, or automatic hold at measurement end point
Auto power off15 minutes if not in use
MemoryUp to 100 data readings
Connector6-pin mini-DIN
CommunicationUSB interface
Power supply3 x 1.5 V AA batteries or 5 V DC power adapter
Battery lifeApproximately 150 hours without backlight
Carrying caseStandard supply
Packing dimensions (L x W x H)345 x 85 x 300 mm
Gross weight1 kg

Support available

  • Calibration
  • Operator training
  • Spares & consumables

Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.