Portable pH / mV Meter
Battery-powered portable pH and mV meter with three-point calibration, automatic buffer recognition and electrode diagnosis, supplied with a carrying case for field work.
Typical applications
- Field pH measurement
- River, lake and effluent sampling
- Water treatment plant rounds
- Agricultural and soil-extract testing
- Site quality checks
Add to enquiry
Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.
Worth knowing before you order
A pH electrode and a buffer pouch are supplied; the electrode is a consumable and the meter's own diagnosis routine is how you tell when it is finished. For field use, budget the things the accessories list omits: electrode storage solution (a pH electrode carried dry in a case will not survive), spare buffer sachets, and the third calibration buffer. The catalogue calls this a pH/ORP meter in its index and the meter does read mV, but no ORP electrode is supplied. The auto-power-off time is printed as 30 minutes in the specification table and 15 minutes in the feature list; the table figure is the one reproduced above.Specification
| pH range | −2.00 to 20.00 pH |
|---|---|
| pH resolution | 0.01 pH |
| pH accuracy | ± 0.01 pH |
| Calibration and buffer sets | 1 to 3 points; USA (4.01 / 7.00 / 10.01) or NIST (4.01 / 6.86 / 9.18) |
| Electrode diagnosis | Automatic, indicates when the pH electrode should be replaced |
| mV range | ± 1999 mV |
| mV resolution / accuracy | 1 mV / ± 1 mV |
| Temperature range | 0 to 105 °C / 32 to 221 °F |
| Temperature resolution / accuracy | 0.1 °C / ± 0.5 °C |
| Temperature compensation | 0 to 100 °C, manual or automatic |
| Hold function | Manual or auto-read measurement end point |
| Display | LCD with white backlight |
| Interface | USB |
| Electrode connector | BNC |
| Auto off | 30 minutes if not in use (see note) |
| Memory | 100 data sets |
| Power supply | 3 x 1.5 V AA batteries or 5 V DC power adapter |
| Battery life | Approximately 150 hours without backlight |
| Carrying case | Standard supply |
| Packing dimensions (L x W x H) | 340 x 90 x 300 mm |
| Gross weight | 2 kg |
Support available
- Calibration
- Operator training
- Spares & consumables
Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.
Related products
Analytical Balance, 220 g × 0.1 mg
Four-decimal analytical balance with draught shield and internal or external calibration.
Ex-stockISO/IEC 17025Capacity: 220 g
Specification for Analytical Balance, 220 g × 0.1 mg
Specification for Analytical Balance, 220 g × 0.1 mg Capacity 220 g Readability 0.1 mg (0.0001 g) Repeatability ≤ 0.1 mg Linearity ± 0.2 mg Pan size 90 mm ø Calibration Internal motorised or external OIML class E2 weight Services Installation & commissioning · Calibration · Operator training · Annual maintenance contract Standards
ISO/IEC 17025Typical applications
- Weighing for standard and reagent preparation
- Gravimetric analysis
- Sample weighing for assay
Full record, hazard data and enquiry for Analytical Balance, 220 g × 0.1 mg →
pH Meter, Benchtop, Five-Point Calibration
Microprocessor benchtop pH and mV meter with automatic temperature compensation and up to five-point calibration.
Ex-stockpH range: −2.00 to 16.00
Specification for pH Meter, Benchtop, Five-Point Calibration
Specification for pH Meter, Benchtop, Five-Point Calibration pH range −2.00 to 16.00 pH resolution 0.01 (0.001 on selected models) Accuracy ± 0.01 pH Calibration points Up to 5, with auto buffer recognition Temperature ATC, −10 to 110 °C Output RS-232 / USB, optional printer Services Installation & commissioning · Calibration · Operator training · Annual maintenance contract · Spares & consumables Typical applications
- pH measurement in water, effluent and process samples
- Pharmaceutical QC pH determination
Full record, hazard data and enquiry for pH Meter, Benchtop, Five-Point Calibration →
UV-Visible Spectrophotometer, Double Beam
Double-beam UV-Vis spectrophotometer for quantitative absorbance and scanning work.
IndentUSP <857>Wavelength range: 190–1100 nm
Specification for UV-Visible Spectrophotometer, Double Beam
Specification for UV-Visible Spectrophotometer, Double Beam Wavelength range 190–1100 nm Spectral bandwidth 1 nm (2 nm and variable on selected models) Wavelength accuracy ± 0.3 nm Photometric range −0.3 to 3.0 A Stray light < 0.05% T at 220 nm Software PC control; 21 CFR Part 11 package to order Services Installation & commissioning · Calibration · Validation & qualification · Operator training · Annual maintenance contract · Spares & consumables Standards
USP <857>Typical applications
- Quantitative assay by absorbance
- COD, nitrate, phosphate and metals colorimetry
- Dissolution and content uniformity testing
Full record, hazard data and enquiry for UV-Visible Spectrophotometer, Double Beam →
Kjeldahl Digestion and Distillation Unit
Digestion block with fume scrubber and steam distillation unit for total nitrogen and crude protein determination.
IndentDigestion positions: 3, 6, 8 or 12
Specification for Kjeldahl Digestion and Distillation Unit
Specification for Kjeldahl Digestion and Distillation Unit Digestion positions 3, 6, 8 or 12 Digestion temperature Up to 450 °C, PID controlled Fume scrubber Water aspirator or recirculating, with neutralisation Distillation Steam generator with automatic alkali dosing Recovery ≥ 99.5% on ammonium sulphate reference Site preparation Required — foundation or utilities Services Installation & commissioning · Calibration · Operator training · Annual maintenance contract · Spares & consumables Typical applications
- Crude protein in food and feed
- Total Kjeldahl nitrogen in water and effluent
- Nitrogen in soil and fertiliser
Full record, hazard data and enquiry for Kjeldahl Digestion and Distillation Unit →