Vicat Needle Apparatus
Determines standard consistency and initial and final setting time of cement paste.
Typical applications
- Standard consistency of cement
- Initial and final setting time of cement and cement blends
Conforms to
- IS 5513—Vicat apparatus — Specification
- IS 4031 (Part 4)—Determination of consistency of standard cement paste
- IS 4031 (Part 5)—Determination of initial and final setting times
- EN 196-3—Determination of setting times and soundness
Add to enquiry
Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.
Specification
| Plunger | 10 ± 0.05 mm ø × 50 ± 1 mm long |
|---|---|
| Initial setting needle | 1.13 mm ø (1 mm²) square section |
| Final setting needle | Annular attachment, 5 mm from tip |
| Moving assembly mass | 300 ± 1 g |
| Scale | 0–50 mm graduated, 1 mm divisions |
| Rod clearance | 0.25 mm, with dashpot damping |
Support available
- Calibration
- Spares & consumables
Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.
Related products
Compression Testing Machine, 2000 kN, Digital
Digital compression testing machine with controlled pace rate for concrete cubes, cylinders and cement mortar specimens.
IndentIS 14858Capacity: 2000 kN (also 500, 1000, 1500 and 3000 kN)
Specification for Compression Testing Machine, 2000 kN, Digital
Specification for Compression Testing Machine, 2000 kN, Digital Capacity 2000 kN (also 500, 1000, 1500 and 3000 kN) Pace rate 1–20 kN/s, displayed and controlled Readout Direct load in kN and stress in N/mm² Accuracy class Grade A, ±1% of indicated load Frame Four-column welded steel Platens Hardened, ground and lapped Power 415 V, 3-phase, 50 Hz Site preparation Required — foundation or utilities Services Installation & commissioning · Calibration · Operator training · Annual maintenance contract · Spares & consumables Standards
IS 14858IS 516 (Part 1/Sec 1) : 2021Typical applications
- Compressive strength of concrete cubes and cylinders
- Compressive strength of cement mortar
- Compressive strength of masonry units
Full record, hazard data and enquiry for Compression Testing Machine, 2000 kN, Digital →
Slump Test Apparatus
Slump cone, base plate and tamping rod for measuring the workability of fresh concrete.
Ex-stockIS 1199 (Part 2) : 2018Cone dimensions: 200 mm bottom ø × 100 mm top ø × 300 mm high
Specification for Slump Test Apparatus
Specification for Slump Test Apparatus Cone dimensions 200 mm bottom ø × 100 mm top ø × 300 mm high Cone material Metal, minimum 1.6 mm (16 SWG) thickness Tamping rod 16 mm ø × 600 mm, hemispherical tip Base plate Machined steel with foot rests Services Spares & consumables Standards
IS 1199 (Part 2) : 2018IS 7320ASTM C143Typical applications
- Workability of fresh concrete at batching plant and site
Full record, hazard data and enquiry for Slump Test Apparatus →
Le Chatelier Mould, Set of Six
Split brass cylinders with indicator arms for determining the soundness of cement by expansion.
Ex-stockIS 4031 (Part 3)Cylinder: 30 mm internal ø × 30 mm high, 0.5 mm wall
Specification for Le Chatelier Mould, Set of Six
Specification for Le Chatelier Mould, Set of Six Cylinder 30 mm internal ø × 30 mm high, 0.5 mm wall Indicator arms 165 mm long from centre of cylinder Material Brass Supplied with Glass plates and 100 g lead weights Services Spares & consumables Standards
IS 4031 (Part 3)IS 5514EN 196-3Typical applications
- Soundness of cement by Le Chatelier expansion
Full record, hazard data and enquiry for Le Chatelier Mould, Set of Six →
Blaine Air Permeability Apparatus
Determines the fineness of cement and pozzolana as specific surface area by air permeability.
IndentIS 4031 (Part 2)Permeability cell: Brass, with perforated disc and plunger
Specification for Blaine Air Permeability Apparatus
Specification for Blaine Air Permeability Apparatus Permeability cell Brass, with perforated disc and plunger Manometer U-tube with four etched marks Result Specific surface in cm²/g or m²/kg Reference material Requires standard cement for cell calibration Services Calibration · Spares & consumables Standards
IS 4031 (Part 2)IS 5516ASTM C204EN 196-6Typical applications
- Fineness of OPC, PPC, PSC, fly ash and GGBS
Full record, hazard data and enquiry for Blaine Air Permeability Apparatus →