Automatic Polarimeter, Dual Wavelength, with CFR Software
Automatic polarimeter that reads optical rotation at 546 nm and 589 nm with Peltier control of the sample tube, and carries audit-trail and electronic-signature software.
Typical applications
- Pharmaceutical identity and assay by optical rotation
- Essential oils and flavours
- Sugar and sweetener manufacture
- Chiral synthesis and process monitoring
Conforms to
- USP <781>—Optical rotation
Add to enquiry
Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.
Worth knowing before you order
A rotation reading only means something with three other numbers beside it: the path length of the tube, the wavelength and the sample temperature. This model gives you two wavelengths — the mercury green line at 546 nm as well as the sodium D line at 589 nm — and a Peltier tube, but the catalogue prints neither the measuring range in degrees nor the temperature control range and accuracy, and the specification table did not survive scanning. Ask for all three in writing. The CFR designation buys the software features — audit trail, user accounts and permissions, electronic signature — not a certificate; 21 CFR Part 11 compliance is demonstrated by your own validated process, and the GMP, GLP and FDA wording printed alongside is the manufacturer's claim.Specification
| Measured quantity | Optical rotation, in degrees |
|---|---|
| Working wavelengths | 546 nm and 589 nm |
| Reading resolution | Three decimal places |
| Measuring modes | Optical rotation, specific rotation, sugar, concentration, user-defined |
| Temperature control | Internal Peltier; the catalogue prints no control range and no control accuracy |
| Sample tubes supplied | 100 mm and 200 mm glass tubes, plus Peltier tube accessories |
| Calibration | Multipoint automatic calibration |
| Display | 8 inch colour touch screen |
| Operating software | Windows-based and on board; no separate PC is required |
| Data storage | 16 GB |
| Record export | PDF or Excel, to local storage or a USB stick |
| Data transmission | To a server, over UDP or RS-232, as text or XML |
| Alarms | Configurable limits on measured value, transmittance and temperature |
| Security software | User accounts, password policy, user and screen lock, electronic signature with a reason of confirm, check or approve |
| Standard accessories | 100 mm and 200 mm glass test tubes, syringe, fuse, power cable, test tube and Peltier tube accessories, cleaning brushes, touch pen, instruction manual, test certificate |
| HSN code | 90275030 |
Support available
- Installation & commissioning
- Calibration
- Validation & qualification (IQ/OQ/PQ)
- Operator training
- Annual maintenance contract
- Spares & consumables
Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.
Related products
Automatic Density Meter, Oscillating U-Tube
Bench density meter that reads the density of a liquid from the resonant frequency of a vibrating quartz U-tube, on a sample of 2 to 3 mL.
IndentASTM D4052Measuring principle: Oscillating quartz glass U-tube with photoelectric detection
Specification for Automatic Density Meter, Oscillating U-Tube
Specification for Automatic Density Meter, Oscillating U-Tube Measuring principle Oscillating quartz glass U-tube with photoelectric detection Density range, two models 0 to 3.0000 g/cm³ on the standard model; 0 to 3.00000 g/cm³ on the CFR model Sample volume 2 to 3 mL per measurement Temperature control Built-in Peltier; the catalogue prints no control range and no control accuracy Sample introduction Manual injection or automatic sampling Bubble checking 1080p camera over the tube, with video of the injection so the operator can see bubbles and particles Display 10.1 inch touch screen, Android operating system Records Results saved as PDF reports and exported to USB; batch collection and storage Interfaces RS-232C serial, USB Cleaning Built-in air pump for drying and cleaning the tube Printer Thermal printer offered as an option CFR model software Adds user accounts and permissions, audit trail and electronic signature on records 3 further specifications on the full record.
Standards
ASTM D4052Typical applications
- Petroleum and petrochemical products
- Pharmaceutical quality control
- Chemicals
- Food and beverage
- Physics and chemistry teaching laboratories
Also known as
- Digital density meter
- Oscillating U-tube density meter
- Specific gravity meter
- Relative density meter
Full record, hazard data and enquiry for Automatic Density Meter, Oscillating U-Tube →
Melting Point Apparatus, Capillary, Touch Screen
Capillary melting point apparatus that heats the sample under PID control, records the melting curve and averages the initial and final melting points.
IndentUSP <741>Method: Capillary tube in a heated block
Specification for Melting Point Apparatus, Capillary, Touch Screen
Specification for Melting Point Apparatus, Capillary, Touch Screen Method Capillary tube in a heated block Temperature control PID with PWM output; no temperature range, heating-rate range or accuracy is printed in the catalogue Reading Melting curve recorded automatically Calculation Average of the initial and final melting points computed automatically Display 7 inch LCD touch screen Clock Real-time clock fitted Data transfer Connects to a computer Detection From the melting curve; no camera or video is listed for this model Standard accessories Capillary tubes, power cord, instruction manual, test certificate HSN code 90278090 Services Installation & commissioning · Calibration · Validation & qualification · Operator training · Spares & consumables Standards
USP <741>Typical applications
- Pharmaceutical identity and purity checks
- Dyestuffs
- Perfumery raw materials
- Organic crystalline substances
Also known as
- Digital melting point apparatus
- Capillary melting point tester
- Melting range apparatus
Full record, hazard data and enquiry for Melting Point Apparatus, Capillary, Touch Screen →
Automatic Video Melting Point Apparatus with CFR Software
Automatic melting point apparatus that measures four capillaries at once under a camera, with video playback and audit-trail software for regulated laboratories.
IndentUSP <741>Method: Capillary tube in a heated block, observed by camera
Specification for Automatic Video Melting Point Apparatus with CFR Software
Specification for Automatic Video Melting Point Apparatus with CFR Software Method Capillary tube in a heated block, observed by camera Capillaries per run 4 Camera 720p, with video capture and playback of the melt Measuring modes Automatic detection, or visual determination from the video Temperature control PID with PWM output; no temperature range, heating-rate range or accuracy is printed in the catalogue Dark-coloured samples Light source brightness and detection sensitivity are adjustable Display 10.1 inch touch screen, Android operating system Stored graphs 40,000 sets Software User accounts and permissions, audit tracking, measurement and operation records Backup Scheduled backup to USB stick or to a file path Standard accessories Power cord, capillary tubes, instruction manual, test certificate HSN code 90278090 1 further specification on the full record.
Standards
USP <741>Typical applications
- Pharmaceutical identity and purity checks
- Dyestuffs
- Perfumery raw materials
- Organic crystalline substances
Also known as
- Video melting point apparatus
- Automatic melting point tester
- Melting range apparatus with audit trail
Full record, hazard data and enquiry for Automatic Video Melting Point Apparatus with CFR Software →
Automatic Polarimeter, Single Wavelength, with CFR Software
Automatic polarimeter that reads optical rotation at 589 nm with Peltier control of the sample tube, and carries audit-trail and electronic-signature software.
IndentUSP <781>Measured quantity: Optical rotation, in degrees
Specification for Automatic Polarimeter, Single Wavelength, with CFR Software
Specification for Automatic Polarimeter, Single Wavelength, with CFR Software Measured quantity Optical rotation, in degrees Working wavelength 589 nm Reading resolution Three decimal places Measuring modes Optical rotation, specific rotation, sugar, concentration, user-defined Stored methods 1000 measurement methods can be pre-set Temperature control Internal Peltier; the catalogue prints no control range and no control accuracy Sample tubes supplied 100 mm and 200 mm glass tubes, plus a 100 mm Peltier tube Repeat measurement Six readings with the average and standard deviation displayed Display 10.1 inch colour touch screen Operating system Android Power-on self check Database, communication serial port, temperature sensor, high-voltage controller and encoder Security software User accounts and permission list, electronic signature verified by password, audit log 3 further specifications on the full record.
Standards
USP <781>Typical applications
- Pharmaceutical identity and assay by optical rotation
- Essential oils and flavours
- Sugar and sweetener manufacture
- Chiral synthesis and process monitoring
Also known as
- Automatic polarimeter
- Digital polarimeter
- Saccharimeter
- Optical rotation meter