Indent

Automatic Video Melting Point Apparatus with CFR Software

Automatic melting point apparatus that measures four capillaries at once under a camera, with video playback and audit-trail software for regulated laboratories.

Typical applications

  • Pharmaceutical identity and purity checks
  • Dyestuffs
  • Perfumery raw materials
  • Organic crystalline substances

Conforms to

USP <741>
  • USP <741>Melting range or temperature

Add to enquiry

Enquire on WhatsApp

Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.

Worth knowing before you order

The specification table did not survive scanning, so the temperature range, the heating-rate range and the temperature accuracy are not given here. Do not read the figures on the screen images in the catalogue as specifications — 50 to 100 °C at 2.0 °C/min is an example method someone typed in, not the instrument's capability. The CFR designation buys the software: audit trail, user accounts and permissions, electronic records and signature. 21 CFR Part 11 compliance is demonstrated by your own validated process — the procedures, the qualification records and the change control around the instrument — not by the machine, and the GMP, GLP and FDA wording printed alongside is the manufacturer's claim.

Specification

Technical specification for Automatic Video Melting Point Apparatus with CFR Software
MethodCapillary tube in a heated block, observed by camera
Capillaries per run4
Camera720p, with video capture and playback of the melt
Measuring modesAutomatic detection, or visual determination from the video
Temperature controlPID with PWM output; no temperature range, heating-rate range or accuracy is printed in the catalogue
Dark-coloured samplesLight source brightness and detection sensitivity are adjustable
Display10.1 inch touch screen, Android operating system
Stored graphs40,000 sets
SoftwareUser accounts and permissions, audit tracking, measurement and operation records
BackupScheduled backup to USB stick or to a file path
Standard accessoriesPower cord, capillary tubes, instruction manual, test certificate
HSN code90278090

Support available

  • Installation & commissioning
  • Calibration
  • Validation & qualification (IQ/OQ/PQ)
  • Operator training
  • Annual maintenance contract
  • Spares & consumables

Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.