Digital Water Bath, 2 / 4 / 6 / 8 Hole
Stainless steel digital water bath in four sizes from 6 to 24 litres, with 125 mm concentric-ring openings, PID control and a drain valve, for heating samples in beakers and flasks.
Typical applications
- Heating biological and biochemical samples
- Cell and bacteria culture at set temperature
- Reagent warming and sample thawing
- Enzyme and serological incubation
- Evaporation and extraction in beakers and flasks
Add to enquiry
Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.
Worth knowing before you order
The floor of the range is RT+10 °C, not the RT+5 °C usual on this class of bath, so in a 25 °C laboratory the lowest setting that will actually hold is around 35 °C - a 30 °C incubation is out of reach in a warm room, and the bath cannot cool at all. Size it on the openings rather than the litres: every model has the same 125 mm holes with five concentric cover rings each, so the real choice between 2, 4, 6 and 8 holes is how many vessels go in at once and what diameter they are. Check the socket before ordering the largest: the 8-hole model draws 1950 W, close to 9 A at 220 V, which is more than a shared bench circuit will carry alongside other equipment. A drain valve and a low-water cut-out are fitted, and SS and ABS beaker holders and a protection cover are in the standard kit.Specification
| Number of holes, 2H / 4H / 6H / 8H | 2 / 4 / 6 / 8 |
|---|---|
| Volume (approx.), 2H / 4H / 6H / 8H | 6 L / 12 L / 18 L / 24 L |
| Linear size (L x W x H), 2H / 4H / 6H / 8H | 301 x 157 x 142 mm / 304 x 304 x 138 mm / 305 x 470 x 138 mm / 305 x 610 x 138 mm |
| Hole size | 125 mm |
| Cover ring per hole | 5 rings per hole |
| Temperature range | RT +10°C ~ 100°C |
| Temperature resolution | 0.1°C |
| Temperature accuracy | 0.5°C |
| Temperature control mode | PID, microcomputer program |
| Heater | Stainless steel U type heating element |
| Water outlet | Independent drain valve |
| Wetted materials | Stainless steel pot, stamped inner liner with sealing structure; stainless steel and PC on all water contact surfaces |
| Display | White LED, dual digital tube for temperature and timing |
| Timer | Yes, with timing function and auto stop |
| Low water protection sensor | Available, prevents dry burning |
| Power, 2H / 4H / 6H / 8H | 650 W / 900 W / 1400 W / 1950 W |
| Power supply | AC220V / 50-60Hz |
| Gross weight, 2H / 4H / 6H / 8H | 4 kg / 6 kg / 8 kg / 10 kg |
| Supplied with | Heat coil, protection cover, SS beaker holder, ABS beaker holder, power cord, instruction manual, test certificate |
| HSN code | 84192090 |
Support available
- Installation & commissioning
- Calibration
- Operator training
- Spares & consumables
Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.
Related products
Muffle Furnace, 1200 °C
Programmable high-temperature muffle furnace for ashing, loss on ignition and heat treatment.
Ex-stockIS 4032Maximum temperature: 1200 °C (1400 °C on request)
Specification for Muffle Furnace, 1200 °C
Specification for Muffle Furnace, 1200 °C Maximum temperature 1200 °C (1400 °C on request) Chamber sizes 4 L, 7 L, 12 L and 22 L Control PID with digital display; programmable ramp-soak to order Stability ± 5 °C at set point Heating elements Kanthal A1 on ceramic; SiC rods on 1400 °C models Insulation Ceramic fibre Services Installation & commissioning · Calibration · Validation & qualification · Annual maintenance contract · Spares & consumables Standards
IS 4032Typical applications
- Loss on ignition of cement, fly ash and aggregate
- Ash content of coal, food and polymer
- Sulphate and chloride content preparation
Full record, hazard data and enquiry for Muffle Furnace, 1200 °C →
Hot Air Oven, Digital, 250 °C
Forced-convection laboratory oven with stainless steel chamber for drying, moisture determination and dry-heat sterilisation.
Ex-stockIS 2720 (Part 2)Temperature range: Ambient +10 °C to 250 °C (300 °C on request)
Specification for Hot Air Oven, Digital, 250 °C
Specification for Hot Air Oven, Digital, 250 °C Temperature range Ambient +10 °C to 250 °C (300 °C on request) Uniformity ± 2 °C at 105 °C Chamber Stainless steel 304, sizes from 45 L to 336 L Air circulation Forced, with adjustable fresh-air damper Control Digital PID with over-temperature cut-out Services Installation & commissioning · Calibration · Validation & qualification · Annual maintenance contract · Spares & consumables Standards
IS 2720 (Part 2)Typical applications
- Moisture content of soil, aggregate and food
- Drying of glassware and samples
- Dry-heat sterilisation
Full record, hazard data and enquiry for Hot Air Oven, Digital, 250 °C →
Vacuum Oven, Laboratory, 27 Litres
Double-walled 27-litre vacuum oven with a mirror-polished stainless steel 316 chamber and PID control from 50 °C to 200 °C, for drying heat-sensitive materials at reduced pressure.
IndentTemperature range: 50 °C to 200 °C
Specification for Vacuum Oven, Laboratory, 27 Litres
Specification for Vacuum Oven, Laboratory, 27 Litres Temperature range 50 °C to 200 °C Vacuum range 50 to 760 mm of Hg Controller PID digital controller with auto-tune Inner chamber Stainless steel 316, mirror polished Construction Double walled, with stainless steel 304 exterior Observation window Thick tempered glass Shelves Two, removable Capacity 27 litres Working chamber 300 × 300 × 300 mm (12 × 12 × 12 inch) Power 1750 W Power supply 230 V, 50 Hz, single phase, AC Typical applications
- Vacuum drying of heat-sensitive materials
- Uniform drying of laboratory samples
- Industrial drying of heat-sensitive product
Full record, hazard data and enquiry for Vacuum Oven, Laboratory, 27 Litres →
Vertical Autoclave, Fully Automatic
Triple-walled vertical steam steriliser with automatic cycle control, in standard and GMP specifications.
IndentISO 17665Operating condition: 121 °C at 15 psi (1.05 kg/cm²)
Specification for Vertical Autoclave, Fully Automatic
Specification for Vertical Autoclave, Fully Automatic Operating condition 121 °C at 15 psi (1.05 kg/cm²) Chamber volumes 35 L, 53 L, 78 L, 95 L, 119 L and 178 L Construction Stainless steel 304 chamber; 316 on GMP models Safety Spring-loaded safety valve, pressure switch, vacuum breaker Control PLC with HMI, cycle printout on GMP models Documentation IQ / OQ / PQ protocols available Site preparation Required — foundation or utilities Services Installation & commissioning · Calibration · Validation & qualification · Operator training · Annual maintenance contract · Spares & consumables Standards
ISO 17665Typical applications
- Sterilisation of culture media and glassware
- Decontamination of biological waste
- Pharmaceutical and hospital sterilisation
Full record, hazard data and enquiry for Vertical Autoclave, Fully Automatic →