Total Organic Carbon Analyser, UV Oxidation with NDIR Detection
Total organic carbon analyser that oxidises the sample by UV and wet chemistry and measures the carbon dioxide released on a non-dispersive infrared detector, reporting TC, TIC, TOC and NPOC.
Typical applications
- Waste water and effluent monitoring
- Source, surface and drinking water
- Cleaning validation swab and rinse samples
- Purified water and water for injection
- Process and cooling water in industry
Add to enquiry
Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.
Worth knowing before you order
The detector decides what this instrument is for. Infrared detection of the CO2 released by oxidation tolerates dirty and salty samples - up to 85 g/L salinity and particles to 0.2 mm - and reads all the way to 10,000 mg/L, which is effluent, process water and source water territory. A conductivity-detection TOC will not do that work. What it costs is a running utility and a computer: nitrogen at ≥99.995% purity is required and only the decompression device is supplied, not the cylinder or the gas, and the analyser is computer-controlled, so a PC has to be provided and kept with the instrument. The autosampler is optional, so unattended batches are an extra line. The software offers electronic signatures and log export; a regulatory data-integrity claim is met by the user's validated configuration and procedures, not by the feature list.Specification
| Detection method | Wet chemical oxidation by UV |
|---|---|
| Detector | NDIR (non-dispersive infrared) |
| Measurement range | 0-10000 mg/L (ppm) |
| Detection limit | 5 µg/L (ppb) |
| Maximum salinity | 85 g/L |
| Particle size accepted | ≤0.2 mm |
| Repeatability tolerance | 3% |
| Analysis parameters | TC, TIC, TOC, NPOC |
| Sample type | Liquid sample |
| Gas requirement | Nitrogen, purity ≥99.995% |
| Control | Computer control; PC software supplied on pen drive |
| Software functions | User management and permissions, sample registration, standard curve management, real-time peak display, measurement records, operation log export to Excel or PDF, electronic signature, consumable usage timers |
| Auto sampler | Optional |
| Interface | USB |
| Other features | Automatic leakage detection system; precise gas flow control; modular design |
| Relative humidity | ≤ 85% |
| Power supply | AC 220V, 50/60Hz |
| Packing dimension (L x W x H) | 660 x 610 x 685 mm |
| Gross weight | 43 kg |
| HSN code | 90275090 |
Support available
- Installation & commissioning
- Calibration
- Validation & qualification (IQ/OQ/PQ)
- Operator training
- Annual maintenance contract
- Spares & consumables
Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.
Related products
COD Digestion Apparatus with Glassware
Reflux digestion block with condensers and glassware for chemical oxygen demand determination.
Ex-stockIS 3025 (Part 58)Positions: 6 or 8
Specification for COD Digestion Apparatus with Glassware
Specification for COD Digestion Apparatus with Glassware Positions 6 or 8 Temperature 150 °C ± 2 °C, digital control Timer Digital, 0–180 minutes with auto shut-off Glassware Borosilicate 3.3 flasks and Liebig condensers Services Installation & commissioning · Calibration · Annual maintenance contract · Spares & consumables Standards
IS 3025 (Part 58)Typical applications
- COD of industrial effluent, sewage and surface water
Full record, hazard data and enquiry for COD Digestion Apparatus with Glassware →
Jar Test Apparatus (Flocculator), Six Position
Six-paddle stirrer with synchronised speed control for optimising coagulant dose in water treatment.
Ex-stockASTM D2035Positions: 6
Specification for Jar Test Apparatus (Flocculator), Six Position
Specification for Jar Test Apparatus (Flocculator), Six Position Positions 6 Speed range 10–300 rpm, digital display Beakers 1000 ml or 2000 ml, with illuminated base Timer Digital with programmable rapid and slow mix stages Services Installation & commissioning · Calibration · Annual maintenance contract · Spares & consumables Standards
ASTM D2035Typical applications
- Coagulant and flocculant dose optimisation
- Water and effluent treatment plant control
Full record, hazard data and enquiry for Jar Test Apparatus (Flocculator), Six Position →
Total Organic Carbon Analyser, UV Oxidation with Conductivity Detection
Reagent-free TOC analyser for high-purity water that oxidises carbon with a UV lamp and measures the resulting conductivity change, in an offline model and an online/offline model.
IndentMode, offline model / online model: Offline / online (exclusive for lab), online and offline switchable
Specification for Total Organic Carbon Analyser, UV Oxidation with Conductivity Detection
Specification for Total Organic Carbon Analyser, UV Oxidation with Conductivity Detection Mode, offline model / online model Offline / online (exclusive for lab), online and offline switchable Detector Conductivity detector Oxidation UV lamp; no acid, gas or catalyst required Detection range (as printed) 0.001-1.500 mg/l (ppm) Measurement range (as printed) 1 µg/L - 1000 µg/L Detection limit 1 ppb Max tolerance ±5% Repeatability tolerance ±3% Analysis time < 3 min Response time < 10 min Sample temperature 1-95°C Environment temperature 10-40°C with temperature change ±5°C/day 9 further specifications on the full record.
Typical applications
- Purified water and water for injection release testing
- Microelectronics and ultrapure water monitoring
- Cleaning validation rinse water
- Distribution loop monitoring (online model)
Also known as
- TOC analyser
- Conductivity TOC analyser
- Purified water TOC analyser
- WFI TOC analyser
- Online TOC analyser
COD Analyser with 21-Position Digestor
Chemical oxygen demand analyser supplied with a 21-place digestor block, reading COD colorimetrically over two ranges after a two-hour dichromate digestion.
IndentMeasuring ranges: (15~150) mg/L, (150~1500) mg/L
Specification for COD Analyser with 21-Position Digestor
Specification for COD Analyser with 21-Position Digestor Measuring ranges (15~150) mg/L, (150~1500) mg/L Light source Two LED light sources, one for each COD testing range Accuracy ±5% Repeatability ±3% Fluctuation ± 6 mg/L (20 min) Calibration 2 points Display LCD Data Stores 200 sets of measuring data, following GLP norm Interface USB, data transferable to a computer Analyser power supply Adaptor, using AC 220V, 50/60Hz Digestor capacity 21 samples at a time Digestor temperature range 0-165°C 8 further specifications on the full record.
Typical applications
- Water and waste water analysis
- Effluent treatment plant monitoring
- Coking, papermaking and petrochemical process water
- Textile printing, leather and food processing effluent
- Pharmaceutical effluent monitoring
Also known as
- COD meter
- COD analyzer
- Chemical oxygen demand analyser
- COD reactor and photometer
- COD digestor
Full record, hazard data and enquiry for COD Analyser with 21-Position Digestor →