Walk-In Cooling Chamber, 2–8 °C
Prefabricated modular walk-in cold room holding 2 °C to 8 °C, 4,000 to 80,000 litres, for bulk cold-chain storage of pharmaceuticals and biologicals with PLC touch-screen control and data logging.
Typical applications
- Cold-chain storage at 2-8 °C
- Vaccine and biological product storage
- Refrigerated stability storage
- Bulk refrigerated sample storage
Add to enquiry
Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.
Worth knowing before you order
The manufacturer also prints an ICH guideline with no number stated in the brochure, ISO 9001:2015 (certificate, not a test method). Those are not test methods for this instrument, so they are not listed as conformity above — ask us for the certificate itself if you need it.Specification
| Storage conditions fulfilled | 2 °C to 8 °C |
|---|---|
| Construction | Prefabricated modular structure with PUF/Rockwool insulated panels and reinforced floor panel |
| Interior / exterior material | Interior stainless steel; exterior PPGI/stainless steel |
| Observation window | Toughened glass window to inspect samples |
| Racks and trays | Stainless steel racks and trays with adjustable tray heights |
| Refrigeration | CFC free refrigeration systems |
| Chamber illumination | LED light with door switch |
| Control system | 7 inch touch screen HMI display and PLC controller system |
| Data logging | Storage facility up to 21600 readings logged at 1 minute interval |
| Data logging sensors | 4 temperature + 4 RH sensors; in-built data logger (uniformity module) |
| Door access | Magnetic door lock for password protected door access |
| Audit trail | Audit trail generation in HMI display |
| Power failure recovery | Auto resume after power failure (main as well as UPS) |
| User access levels | Three level operation - Admin, Supervisor and General, with fixed access rights |
| Redundancy | Standby refrigeration system; auto switch over facility and calendar programming for mains and standby system |
| Remote alert | GSM module (mobile alert configuration) system |
| PC software | Compatible with 21 CFR Part 11 compliance PC data-acquisition software |
| Safety provisions | Over temperature cutoff system; electrical overload cutoff system; time delay for compressor switch on |
| Working chamber 2.00 x 1.00 x 2.00 m | Capacity 4000 litres; 8 trays |
| Working chamber 2.00 x 1.50 x 2.00 m | Capacity 6000 litres; 12 trays |
| Working chamber 2.00 x 2.00 x 2.00 m | Capacity 8000 litres; 24 trays |
| Working chamber 2.00 x 2.50 x 2.50 m | Capacity 12500 litres; 28 trays |
| Working chamber 2.50 x 3.00 x 2.50 m | Capacity 18750 litres; 36 trays |
| Working chamber 3.10 x 3.00 x 2.50 m | Capacity 23250 litres; 40 trays |
Site preparation required
This instrument needs site work before delivery — typically a level grouted foundation, a dedicated power supply, and in some cases drainage or extraction. We issue the foundation drawing and utility schedule with the quotation so the civil work runs in parallel with the lead time.Support available
- Validation & qualification (IQ/OQ/PQ)
Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.
Related products
Humidity Chamber
Floor-standing double-walled chamber that holds a set temperature and relative humidity with PID control, used by pharmaceutical, chemical and electronics laboratories for controlled-environment storage and testing.
IndentTemperature measurement: By PID controller
Specification for Humidity Chamber
Specification for Humidity Chamber Temperature measurement By PID controller RH measurement By capacitance type RH sensor Temperature range 10 °C to 70 °C Temperature accuracy ± 0.1 °C Humidity range 40 % RH to 95 % RH Humidity accuracy ± 3 % RH Construction Double wall construction Interior material High grade stainless steel (S.S. 304 / S.S. 316) Exterior material Mild steel or stainless steel (S.S. 304 / S.S. 316) Humidity system Non-condensing steam injection type, with water level circuit Heating Long lasting SS tubular heaters Refrigeration Hermetically sealed compressor, CFC free refrigerant (134 A gas), evaporation coil and condenser 13 further specifications on the full record.
Typical applications
- Drug and drug substance testing
- Plant and vegetable testing
- Electronic chips and components testing
- Paint, cement and chemical testing
Stability Chamber
Touch-screen PLC controlled temperature and humidity chamber that holds ICH storage conditions such as 25 °C/60 % RH and 40 °C/75 % RH, used by pharmaceutical QC and R&D laboratories for long-term and accelerated stability studies. Also printed as Humidity Chamber.
IndentStorage conditions fulfilled: 25 °C / 60 % RH; 30 °C / 65 % RH; 30 °C / 70 % RH; 30 °C / 75 % RH; 40 °C / 75 % RH; 25 °C / 40 % RH; 30 °C / 35 % RH; 40 °C / NMT 25 % RH
Specification for Stability Chamber
Specification for Stability Chamber Storage conditions fulfilled 25 °C / 60 % RH; 30 °C / 65 % RH; 30 °C / 70 % RH; 30 °C / 75 % RH; 40 °C / 75 % RH; 25 °C / 40 % RH; 30 °C / 35 % RH; 40 °C / NMT 25 % RH Temperature accuracy ± 0.1 °C Temperature resolution 0.1 °C Humidity range 40 % RH to 95 % RH Humidity fluctuation Maximum 3 % RH Humidity sensor Capacitance type, enables direct display of RH and temperature Chamber illumination 2 or 4 LED lights for lesser power consumption; LED light with door switch Compressor rating 1.5 KW Dry heater rating 2.0 KW Wet heater rating 3.0 KW Overall power consumption (three phase) 2.5 KW per phase (for 3-phase connection) Power consumption (single phase) 7.0 KW (for single phase connection) 13 further specifications on the full record.
Typical applications
- ICH long-term stability storage
- Accelerated stability studies
- Pharmaceutical shelf-life determination
- Drug and drug substance testing
Full record, hazard data and enquiry for Stability Chamber →
Walk-In Stability Chamber
Prefabricated modular walk-in room, 4,000 to 80,000 litres, that holds ICH temperature and humidity storage conditions for bulk pharmaceutical stability and retention samples under PLC touch-screen control.
IndentStorage conditions fulfilled: 25 °C / 60 % RH; 30 °C / 65 % RH; 30 °C / 70 % RH; 30 °C / 75 % RH; 40 °C / 75 % RH; 25 °C / 40 % RH; 30 °C / 35 % RH; 40 °C / NMT 25 % RH
Specification for Walk-In Stability Chamber
Specification for Walk-In Stability Chamber Storage conditions fulfilled 25 °C / 60 % RH; 30 °C / 65 % RH; 30 °C / 70 % RH; 30 °C / 75 % RH; 40 °C / 75 % RH; 25 °C / 40 % RH; 30 °C / 35 % RH; 40 °C / NMT 25 % RH Construction Prefabricated modular structure with PUF/Rockwool insulated panels and reinforced floor panel Interior / exterior material Interior stainless steel; exterior PPGI/stainless steel Observation window Toughened glass window to inspect samples Racks and trays Stainless steel racks and trays with adjustable tray heights Refrigeration CFC free refrigeration systems Chamber illumination LED light with door switch Control system 7 inch touch screen HMI display and PLC controller system Data logging Storage facility up to 21600 readings logged at 1 minute interval Data logging sensors 4 temperature + 4 RH sensors; in-built data logger (uniformity module) Door access Magnetic door lock for password protected door access Audit trail Audit trail generation in HMI display 14 further specifications on the full record.
Typical applications
- ICH long-term stability storage
- Accelerated stability studies
- Bulk pharmaceutical sample storage
- Retention sample storage
Full record, hazard data and enquiry for Walk-In Stability Chamber →
Cooling Chamber, 2–8 °C
Cabinet-style refrigerated chamber holding 2 °C to 8 °C in sizes from 92 to 1012 litres, for cold storage of pharmaceutical samples and reagents with PLC touch-screen control and audit-trail logging.
IndentStorage conditions fulfilled: 2 °C to 8 °C
Specification for Cooling Chamber, 2–8 °C
Specification for Cooling Chamber, 2–8 °C Storage conditions fulfilled 2 °C to 8 °C Control accuracy ± 0.5 °C Air circulation Uniform forced-air circulation system across the working chamber Interior material Internal chamber fabricated from stainless steel S.S.-304/316 grade Exterior material Exterior body fabricated from S.S.-304/316 grade material Observation door Full view poly-carbonate observation door to inspect test samples Racks and trays Stainless steel racks and trays with adjustable tray heights Refrigeration CFC free refrigeration systems Chamber illumination LED light with door switch Mobility Unit mounted on castor wheels for easy movement Control system 7 inch touch screen HMI display and PLC controller system Data logging Storage facility up to 21600 readings logged at 1 minute interval 16 further specifications on the full record.
Typical applications
- Cold-chain storage at 2-8 °C
- Vaccine and biological product storage
- Refrigerated stability storage
- Laboratory reagent and sample storage
- Hospital and blood-bank cold storage
Full record, hazard data and enquiry for Cooling Chamber, 2–8 °C →