Stability & Environmental Chambers
Stability chambers, humidity chambers, cooling chambers and BOD incubators, in cabinet and walk-in scale, for controlled temperature and relative humidity storage.
20 categories · 244 published records. The catalogue we can supply is broader than the catalogue we publish — send us the item if you cannot find it.
Before you order
A stability chamber is bought for a protocol, not for a temperature range. Before you compare quotations, settle three things: whether you need the chamber qualified on empty, half and full load; whether your electronic records have to satisfy 21 CFR Part 11; and which ICH condition you are storing to. Manufacturers commonly print "designed as per ICH guidelines" without naming a guideline — that phrase is not a specification, and we say so on the records below rather than quoting a number nobody printed. Walk-in units need civil work, drainage and a three-phase supply.
6 records
Cannot find it? Ask on WhatsApp →Humidity Chamber
Floor-standing double-walled chamber that holds a set temperature and relative humidity with PID control, used by pharmaceutical, chemical and electronics laboratories for controlled-environment storage and testing.
IndentTemperature measurement: By PID controller
Specification for Humidity Chamber
Specification for Humidity Chamber Temperature measurement By PID controller RH measurement By capacitance type RH sensor Temperature range 10 °C to 70 °C Temperature accuracy ± 0.1 °C Humidity range 40 % RH to 95 % RH Humidity accuracy ± 3 % RH Construction Double wall construction Interior material High grade stainless steel (S.S. 304 / S.S. 316) Exterior material Mild steel or stainless steel (S.S. 304 / S.S. 316) Humidity system Non-condensing steam injection type, with water level circuit Heating Long lasting SS tubular heaters Refrigeration Hermetically sealed compressor, CFC free refrigerant (134 A gas), evaporation coil and condenser 13 further specifications on the full record.
Typical applications
- Drug and drug substance testing
- Plant and vegetable testing
- Electronic chips and components testing
- Paint, cement and chemical testing
Stability Chamber
Touch-screen PLC controlled temperature and humidity chamber that holds ICH storage conditions such as 25 °C/60 % RH and 40 °C/75 % RH, used by pharmaceutical QC and R&D laboratories for long-term and accelerated stability studies. Also printed as Humidity Chamber.
IndentStorage conditions fulfilled: 25 °C / 60 % RH; 30 °C / 65 % RH; 30 °C / 70 % RH; 30 °C / 75 % RH; 40 °C / 75 % RH; 25 °C / 40 % RH; 30 °C / 35 % RH; 40 °C / NMT 25 % RH
Specification for Stability Chamber
Specification for Stability Chamber Storage conditions fulfilled 25 °C / 60 % RH; 30 °C / 65 % RH; 30 °C / 70 % RH; 30 °C / 75 % RH; 40 °C / 75 % RH; 25 °C / 40 % RH; 30 °C / 35 % RH; 40 °C / NMT 25 % RH Temperature accuracy ± 0.1 °C Temperature resolution 0.1 °C Humidity range 40 % RH to 95 % RH Humidity fluctuation Maximum 3 % RH Humidity sensor Capacitance type, enables direct display of RH and temperature Chamber illumination 2 or 4 LED lights for lesser power consumption; LED light with door switch Compressor rating 1.5 KW Dry heater rating 2.0 KW Wet heater rating 3.0 KW Overall power consumption (three phase) 2.5 KW per phase (for 3-phase connection) Power consumption (single phase) 7.0 KW (for single phase connection) 13 further specifications on the full record.
Typical applications
- ICH long-term stability storage
- Accelerated stability studies
- Pharmaceutical shelf-life determination
- Drug and drug substance testing
Full record, hazard data and enquiry for Stability Chamber →
Walk-In Stability Chamber
Prefabricated modular walk-in room, 4,000 to 80,000 litres, that holds ICH temperature and humidity storage conditions for bulk pharmaceutical stability and retention samples under PLC touch-screen control.
IndentStorage conditions fulfilled: 25 °C / 60 % RH; 30 °C / 65 % RH; 30 °C / 70 % RH; 30 °C / 75 % RH; 40 °C / 75 % RH; 25 °C / 40 % RH; 30 °C / 35 % RH; 40 °C / NMT 25 % RH
Specification for Walk-In Stability Chamber
Specification for Walk-In Stability Chamber Storage conditions fulfilled 25 °C / 60 % RH; 30 °C / 65 % RH; 30 °C / 70 % RH; 30 °C / 75 % RH; 40 °C / 75 % RH; 25 °C / 40 % RH; 30 °C / 35 % RH; 40 °C / NMT 25 % RH Construction Prefabricated modular structure with PUF/Rockwool insulated panels and reinforced floor panel Interior / exterior material Interior stainless steel; exterior PPGI/stainless steel Observation window Toughened glass window to inspect samples Racks and trays Stainless steel racks and trays with adjustable tray heights Refrigeration CFC free refrigeration systems Chamber illumination LED light with door switch Control system 7 inch touch screen HMI display and PLC controller system Data logging Storage facility up to 21600 readings logged at 1 minute interval Data logging sensors 4 temperature + 4 RH sensors; in-built data logger (uniformity module) Door access Magnetic door lock for password protected door access Audit trail Audit trail generation in HMI display 14 further specifications on the full record.
Typical applications
- ICH long-term stability storage
- Accelerated stability studies
- Bulk pharmaceutical sample storage
- Retention sample storage
Full record, hazard data and enquiry for Walk-In Stability Chamber →
Walk-In Cooling Chamber, 2–8 °C
Prefabricated modular walk-in cold room holding 2 °C to 8 °C, 4,000 to 80,000 litres, for bulk cold-chain storage of pharmaceuticals and biologicals with PLC touch-screen control and data logging.
IndentStorage conditions fulfilled: 2 °C to 8 °C
Specification for Walk-In Cooling Chamber, 2–8 °C
Specification for Walk-In Cooling Chamber, 2–8 °C Storage conditions fulfilled 2 °C to 8 °C Construction Prefabricated modular structure with PUF/Rockwool insulated panels and reinforced floor panel Interior / exterior material Interior stainless steel; exterior PPGI/stainless steel Observation window Toughened glass window to inspect samples Racks and trays Stainless steel racks and trays with adjustable tray heights Refrigeration CFC free refrigeration systems Chamber illumination LED light with door switch Control system 7 inch touch screen HMI display and PLC controller system Data logging Storage facility up to 21600 readings logged at 1 minute interval Data logging sensors 4 temperature + 4 RH sensors; in-built data logger (uniformity module) Door access Magnetic door lock for password protected door access Audit trail Audit trail generation in HMI display 14 further specifications on the full record.
Typical applications
- Cold-chain storage at 2-8 °C
- Vaccine and biological product storage
- Refrigerated stability storage
- Bulk refrigerated sample storage
Full record, hazard data and enquiry for Walk-In Cooling Chamber, 2–8 °C →
Cooling Chamber, 2–8 °C
Cabinet-style refrigerated chamber holding 2 °C to 8 °C in sizes from 92 to 1012 litres, for cold storage of pharmaceutical samples and reagents with PLC touch-screen control and audit-trail logging.
IndentStorage conditions fulfilled: 2 °C to 8 °C
Specification for Cooling Chamber, 2–8 °C
Specification for Cooling Chamber, 2–8 °C Storage conditions fulfilled 2 °C to 8 °C Control accuracy ± 0.5 °C Air circulation Uniform forced-air circulation system across the working chamber Interior material Internal chamber fabricated from stainless steel S.S.-304/316 grade Exterior material Exterior body fabricated from S.S.-304/316 grade material Observation door Full view poly-carbonate observation door to inspect test samples Racks and trays Stainless steel racks and trays with adjustable tray heights Refrigeration CFC free refrigeration systems Chamber illumination LED light with door switch Mobility Unit mounted on castor wheels for easy movement Control system 7 inch touch screen HMI display and PLC controller system Data logging Storage facility up to 21600 readings logged at 1 minute interval 16 further specifications on the full record.
Typical applications
- Cold-chain storage at 2-8 °C
- Vaccine and biological product storage
- Refrigerated stability storage
- Laboratory reagent and sample storage
- Hospital and blood-bank cold storage
Full record, hazard data and enquiry for Cooling Chamber, 2–8 °C →
Walk-In BOD Incubator
Prefabricated modular walk-in incubator operating from 5 °C to 60 °C, 4,000 to 80,000 litres, for bulk biochemical oxygen demand testing and microbiological incubation in water, food and pharma laboratories.
IndentStorage conditions fulfilled: 5 °C to 60 °C
Specification for Walk-In BOD Incubator
Specification for Walk-In BOD Incubator Storage conditions fulfilled 5 °C to 60 °C Construction Prefabricated modular structure with PUF/Rockwool insulated panels and reinforced floor panel Interior / exterior material Interior stainless steel; exterior PPGI/stainless steel Observation window Toughened glass window to inspect samples Racks and trays Stainless steel racks and trays with adjustable tray heights Refrigeration CFC free refrigeration systems Chamber illumination LED light with door switch Control system 7 inch touch screen HMI display and PLC controller system Data logging Storage facility up to 21600 readings logged at 1 minute interval Data logging sensors 4 temperature + 4 RH sensors; in-built data logger (uniformity module) Door access Magnetic door lock for password protected door access Audit trail Audit trail generation in HMI display 14 further specifications on the full record.
Typical applications
- Biochemical oxygen demand (BOD) testing
- Microbiological culture incubation
- Bulk controlled-temperature incubation
- Water and effluent analysis laboratories
Full record, hazard data and enquiry for Walk-In BOD Incubator →
What laboratories usually order alongside this.
Cold Storage & Ultra-Low Temperature
Laboratory refrigerators, deep freezers and ultra-low temperature cabinets from +2 °C down to −80 °C, for samples, reagents and cultures.
Ovens, Furnaces & Incubators
Hot air ovens, muffle and high-temperature furnaces, water baths, stability chambers and refrigerated equipment.
Microbiology & Sterilisation
Autoclaves, laminar air flow cabinets, BOD and bacteriological incubators, colony counters and aseptic handling equipment.
Why we publish the standard revision, not just the number.
Testing instruments are bought against a method, and a method is written against a standard. When that standard is revised, the old number stays in circulation for years — sometimes decades — because catalogues copy each other and nobody re-checks.
Three examples currently live across this industry: ASTM D1559 for Marshall stability, withdrawn in 1998. ASTM D422 for hydrometer analysis, withdrawn in 2016. IS 13311 for non-destructive concrete testing, absorbed into the IS 516 family in 2018. All three still appear on product listings you can buy from today.
That matters commercially, not just pedantically. If your quality manual cites a withdrawn standard, a NABL assessor will raise it, and the fastest way that error enters a manual is by being copied off a supplier’s specification sheet.
On qualification: for pharmaceutical customers, the documentation is half the purchase. GMP-specification equipment differs in its contact surfaces, its control system, its printed cycle records and its IQ/OQ/PQ protocol set. Specify that requirement at enquiry stage — retrofitting it after installation costs more and delays qualification.
On site preparation: compression testing machines, ductility baths, abrasion machines and large ovens need foundations, three-phase supply, drainage or extraction. We issue the foundation drawing and utility schedule with the quotation so the civil work can run in parallel with the delivery lead time rather than after it.