Automatic Digital Polarimeter, Touch Screen, with Peltier Sample Tube
Touch-screen digital polarimeter supplied with a 100 mm Peltier sample tube, so that optical rotation is read at a held temperature rather than at whatever the room is doing.
Typical applications
- Purity control and concentration determination
- Sugar industry quality control
- Pharmaceutical quality control
- Monitoring chemical processes
- Analysis of optically active components
Add to enquiry
Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.
Worth knowing before you order
The Peltier tube is what separates these two variants from the two on the facing catalogue page, which carry the same body, the same screen and the same modes but no temperature control at all — the catalogue distinguishes them only in the standard-accessories line. Since the reading moves with sample temperature, that line is the whole purchase decision. Two figures are still missing: the Peltier control range and accuracy are not printed, and neither is the working wavelength, which specific rotation cannot be quoted without. The model-by-model measuring range in degrees did not survive scanning either. Get all of them in writing.Specification
| Measured quantity | Optical rotation, in degrees |
|---|---|
| Measuring modes | Optical rotation and specific rotation, sugar, concentration |
| Measuring principle | Optical null |
| Modulator | Faraday magneto-optical modulator |
| Detector | Photodiode |
| Temperature control | 100 mm Peltier test tube supplied as standard on these two variants; the catalogue prints no control range and no control accuracy |
| Repeat measurement | Automatic repetition up to six times with the average calculated |
| Display | Colour touch screen |
| Wavelength | Not printed in the catalogue for this series |
| Standard accessories, all variants | 100 mm and 200 mm test tubes, touch pen, USB cable, power cord, software pen drive, instruction manual, test certificate |
| Additional accessories on these variants | 100 mm Peltier test tube, test tube cleaning brush, test tube accessories, syringe with needle |
| HSN code | 90275030 |
Support available
- Installation & commissioning
- Calibration
- Validation & qualification (IQ/OQ/PQ)
- Operator training
- Spares & consumables
Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.
Related products
Automatic Density Meter, Oscillating U-Tube
Bench density meter that reads the density of a liquid from the resonant frequency of a vibrating quartz U-tube, on a sample of 2 to 3 mL.
IndentASTM D4052Measuring principle: Oscillating quartz glass U-tube with photoelectric detection
Specification for Automatic Density Meter, Oscillating U-Tube
Specification for Automatic Density Meter, Oscillating U-Tube Measuring principle Oscillating quartz glass U-tube with photoelectric detection Density range, two models 0 to 3.0000 g/cm³ on the standard model; 0 to 3.00000 g/cm³ on the CFR model Sample volume 2 to 3 mL per measurement Temperature control Built-in Peltier; the catalogue prints no control range and no control accuracy Sample introduction Manual injection or automatic sampling Bubble checking 1080p camera over the tube, with video of the injection so the operator can see bubbles and particles Display 10.1 inch touch screen, Android operating system Records Results saved as PDF reports and exported to USB; batch collection and storage Interfaces RS-232C serial, USB Cleaning Built-in air pump for drying and cleaning the tube Printer Thermal printer offered as an option CFR model software Adds user accounts and permissions, audit trail and electronic signature on records 3 further specifications on the full record.
Standards
ASTM D4052Typical applications
- Petroleum and petrochemical products
- Pharmaceutical quality control
- Chemicals
- Food and beverage
- Physics and chemistry teaching laboratories
Also known as
- Digital density meter
- Oscillating U-tube density meter
- Specific gravity meter
- Relative density meter
Full record, hazard data and enquiry for Automatic Density Meter, Oscillating U-Tube →
Melting Point Apparatus, Capillary, Touch Screen
Capillary melting point apparatus that heats the sample under PID control, records the melting curve and averages the initial and final melting points.
IndentUSP <741>Method: Capillary tube in a heated block
Specification for Melting Point Apparatus, Capillary, Touch Screen
Specification for Melting Point Apparatus, Capillary, Touch Screen Method Capillary tube in a heated block Temperature control PID with PWM output; no temperature range, heating-rate range or accuracy is printed in the catalogue Reading Melting curve recorded automatically Calculation Average of the initial and final melting points computed automatically Display 7 inch LCD touch screen Clock Real-time clock fitted Data transfer Connects to a computer Detection From the melting curve; no camera or video is listed for this model Standard accessories Capillary tubes, power cord, instruction manual, test certificate HSN code 90278090 Services Installation & commissioning · Calibration · Validation & qualification · Operator training · Spares & consumables Standards
USP <741>Typical applications
- Pharmaceutical identity and purity checks
- Dyestuffs
- Perfumery raw materials
- Organic crystalline substances
Also known as
- Digital melting point apparatus
- Capillary melting point tester
- Melting range apparatus
Full record, hazard data and enquiry for Melting Point Apparatus, Capillary, Touch Screen →
Automatic Video Melting Point Apparatus with CFR Software
Automatic melting point apparatus that measures four capillaries at once under a camera, with video playback and audit-trail software for regulated laboratories.
IndentUSP <741>Method: Capillary tube in a heated block, observed by camera
Specification for Automatic Video Melting Point Apparatus with CFR Software
Specification for Automatic Video Melting Point Apparatus with CFR Software Method Capillary tube in a heated block, observed by camera Capillaries per run 4 Camera 720p, with video capture and playback of the melt Measuring modes Automatic detection, or visual determination from the video Temperature control PID with PWM output; no temperature range, heating-rate range or accuracy is printed in the catalogue Dark-coloured samples Light source brightness and detection sensitivity are adjustable Display 10.1 inch touch screen, Android operating system Stored graphs 40,000 sets Software User accounts and permissions, audit tracking, measurement and operation records Backup Scheduled backup to USB stick or to a file path Standard accessories Power cord, capillary tubes, instruction manual, test certificate HSN code 90278090 1 further specification on the full record.
Standards
USP <741>Typical applications
- Pharmaceutical identity and purity checks
- Dyestuffs
- Perfumery raw materials
- Organic crystalline substances
Also known as
- Video melting point apparatus
- Automatic melting point tester
- Melting range apparatus with audit trail
Full record, hazard data and enquiry for Automatic Video Melting Point Apparatus with CFR Software →
Automatic Polarimeter, Dual Wavelength, with CFR Software
Automatic polarimeter that reads optical rotation at 546 nm and 589 nm with Peltier control of the sample tube, and carries audit-trail and electronic-signature software.
IndentUSP <781>Measured quantity: Optical rotation, in degrees
Specification for Automatic Polarimeter, Dual Wavelength, with CFR Software
Specification for Automatic Polarimeter, Dual Wavelength, with CFR Software Measured quantity Optical rotation, in degrees Working wavelengths 546 nm and 589 nm Reading resolution Three decimal places Measuring modes Optical rotation, specific rotation, sugar, concentration, user-defined Temperature control Internal Peltier; the catalogue prints no control range and no control accuracy Sample tubes supplied 100 mm and 200 mm glass tubes, plus Peltier tube accessories Calibration Multipoint automatic calibration Display 8 inch colour touch screen Operating software Windows-based and on board; no separate PC is required Data storage 16 GB Record export PDF or Excel, to local storage or a USB stick Data transmission To a server, over UDP or RS-232, as text or XML 5 further specifications on the full record.
Standards
USP <781>Typical applications
- Pharmaceutical identity and assay by optical rotation
- Essential oils and flavours
- Sugar and sweetener manufacture
- Chiral synthesis and process monitoring
Also known as
- Automatic polarimeter
- Digital polarimeter
- Saccharimeter
- Optical rotation meter
Full record, hazard data and enquiry for Automatic Polarimeter, Dual Wavelength, with CFR Software →