Chemical Resistant Diaphragm Vacuum Pump, Two-Stage, 20 L/min
Two-stage oil-free diaphragm pump with a PTFE-coated head, 20 mbar ultimate vacuum and 20 L/min, for corrosive and solvent-laden vapour.
Typical applications
- Suction filtration of corrosive solutions
- Vacuum distillation
- Rotary evaporation
- Vacuum and centrifugal concentration
- Solid phase extraction
Add to enquiry
Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.
Worth knowing before you order
This is the chemically resistant option in the range: PTFE-coated head and diaphragm with FFPM valves, two stages, 20 mbar absolute ultimate vacuum and 20 L/min at atmospheric pressure. Note that the ultimate vacuum is quoted in mbar absolute here and in MPa on the smaller oil-free pump, so the two cannot be compared as printed without converting one of them. Tubing connects at 10 mm and the standard accessories are the pump, the manual and the test certificate only - no tubing, trap, gauge or exhaust filter. Noise is quoted below 70 dB, which is audible on an open bench.Specification
| Pump head type | Two-stage |
|---|---|
| Ultimate vacuum [mbar abs.] | 20 mbar |
| Flow rate [l/min] at atm. pressure | 20 L/min |
| Operation pressure | 1 bar (max) |
| Pump head material and diaphragm | PTFE coated |
| Valves | FFPM |
| Connectors for tube | 10 mm |
| Ambient temperature | +5 °C to +40 °C |
| Noise | <70 db |
| Drive and protection | Motor direct power transmission; overheat protection with automatic temperature cool-down |
| Power | 120 W |
| Power supply | AC 220V / 50Hz |
| Packing dimension (LxWxH) | 465 x 325 x 270 mm |
| Gross weight | 11 kg |
| Standard accessories | Main instrument, instruction manual, test certificate |
| HSN code | 84141090 |
Support available
- Annual maintenance contract
- Spares & consumables
Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.
Related products
High Performance Liquid Chromatography System, Isocratic and Binary Gradient
High performance liquid chromatograph supplied as an isocratic single-pump or binary gradient twin-pump system with a UV detector and a manual six-port injection valve.
IndentSystem, isocratic build / gradient build: Isocratic, one pump / binary gradient, two pumps working in parallel
Specification for High Performance Liquid Chromatography System, Isocratic and Binary Gradient
Specification for High Performance Liquid Chromatography System, Isocratic and Binary Gradient System, isocratic build / gradient build Isocratic, one pump / binary gradient, two pumps working in parallel Pump delivery system Dual-plunger in series, floating plunger design; single-stroke discharged volume 30 ul Flow range 0.001 to 9.999 ml/min, in 0.001 ml/min increments Flow accuracy and precision ± 0.5 % or 10 µL/min; RSD ≤ 0.1% Pressure fluctuation ≤ 0.5% Pressure range ≤ 42 MPa with 316L pump head, ≤ 30 MPa with PEEK pump head Injector 7725i six-port manual valve Detector supplied UV; fluorescence and refractive index detectors offered as options Detection system 190-400 nm (700 nm optional), single or dual wavelength mode selectable Lamp Deuterium or halogen lamp (optional) selectable Wavelength increment, accuracy and precision 1 nm increment; accuracy 1 nm; precision ±0.1 nm Detector drift 2×10-4 AU 9 further specifications on the full record.
Typical applications
- Assay and related substances by HPLC
- Pharmaceutical quality control
- Food and beverage analysis
- Environmental sample analysis
- Method development
Also known as
- High performance liquid chromatograph
- Isocratic HPLC system
- Binary gradient HPLC system
- Liquid chromatography system
Gas Chromatograph with Capillary Injector and Flame Ionisation Detector
Bench gas chromatograph with a capillary injector, a single flame ionisation detector and a column oven programmable to 400 °C, operated from a PC.
IndentSample introduction: Capillary injector, one fitted
Specification for Gas Chromatograph with Capillary Injector and Flame Ionisation Detector
Specification for Gas Chromatograph with Capillary Injector and Flame Ionisation Detector Sample introduction Capillary injector, one fitted Detector FID, one fitted FID detection limit ≤3×10⁻¹² g/s FID drift ≤6×10⁻¹³ A/30 min FID linearity range ≥10⁶ Column oven temperature range RT +7 °C to 400 °C, in 1 °C increments Oven temperature accuracy ± 0.02 °C Cooling time 400 °C to 50 °C in 8-10 min at 25 °C ambient Programmed heating rate 0.1 °C to 40 °C/min, in 1 °C increments Program ramps 7 ramps standard on the instrument, up to 10 ramps with the software Column capacity One capillary column Oven size, inside / outside (L x W x H) 284 x 280 x 241 mm / 340 x 345 x 281 mm 10 further specifications on the full record.
Typical applications
- Benzene series and BTEX (toluene, ethylbenzene, xylenes, styrene, cumene)
- Nitrobenzene compounds (nitrobenzene, dinitrotoluene)
- Chlorobenzene compounds (chlorobenzene, dichlorobenzene, trichlorobenzene)
- Total volatile organic compounds (TVOC)
- Phenolic compounds (phenol, cresol)
Also known as
- Gas chromatograph
- GC-FID
- Capillary gas chromatograph
- Gas chromatography system
Gas Chromatograph with Electronic Pneumatic Control, Split/Splitless Injector and FID
Bench gas chromatograph with electronic pneumatic control, a split and splitless injector and a flame ionisation detector, with a column oven programmable to 420 °C.
IndentPneumatics: EPC, electronic pneumatic control
Specification for Gas Chromatograph with Electronic Pneumatic Control, Split/Splitless Injector and FID
Specification for Gas Chromatograph with Electronic Pneumatic Control, Split/Splitless Injector and FID Pneumatics EPC, electronic pneumatic control Sample introduction Split / splitless injector, one fitted Detector FID, one fitted FID detection limit ≤8×10⁻¹² g/s (n-hexadecane) FID drift and linearity Drift ≤1.5×10⁻¹³ A/h; linearity range ≥10⁶ EPC flow rate 200 ml/min (N2), 1000 ml/min (He) EPC flow accuracy and repeatability ±5% accuracy; ±0.35% repeatability Split ratio 0-5000 (He), 0-1000 (N2) Inlet and column oven temperature range RT +7 °C to 420 °C, the oven in 1 °C increments Oven temperature accuracy ± 0.02 °C Cooling time 350 °C to 100 °C in ≤3 min; 400 °C to 50 °C in 8-10 min at 25 °C ambient Programmed heating rate 0.1 °C to 80 °C/min, in 1 °C increments 10 further specifications on the full record.
Typical applications
- Benzene series and BTEX (toluene, ethylbenzene, xylenes, styrene, cumene)
- Nitrobenzene compounds (nitrobenzene, dinitrotoluene)
- Chlorobenzene compounds (chlorobenzene, dichlorobenzene, trichlorobenzene)
- Total volatile organic compounds (TVOC)
- Phenolic compounds (phenol, cresol)
Also known as
- Gas chromatograph
- GC-FID
- EPC gas chromatograph
- Split splitless gas chromatograph
Autosampler for Gas Chromatography, 22-Position Tray
Automatic liquid sampler that injects from a 22-position tray into a gas chromatograph, for unattended sequences and repeatable injection volumes.
IndentInjector sizes: 1, 5, 10, 25, 50, 100, 250, 500 (µl)
Specification for Autosampler for Gas Chromatography, 22-Position Tray
Specification for Autosampler for Gas Chromatography, 22-Position Tray Injector sizes 1, 5, 10, 25, 50, 100, 250, 500 (µl) Sample tray 22 positions Positions, sample / solvent / waste 19 / 2 / 1 Sample size range 0.1 µl (with a 1 µl syringe) to 250 µl (with a 500 µl syringe) Sample injection times of each line 1 to 99 times Maximum interval 999 min Methods 1 to 20 Maximum injection inlets 1 Needle cleaning and sample pumping Up to 99 times each; maximum pumping interval 5000 ms Viscosity delay 0 to 60 s Dwell time before and after injection 0 to 120 s Needle speed Fast, slow, user-defined 9 further specifications on the full record.
Typical applications
- Unattended overnight GC sequences
- Routine QC batches
- Solvent wash and blank sequences
- Bar-coded sample tracking
Also known as
- GC autosampler
- Auto sampler for gas chromatograph
- Automatic liquid sampler
- Liquid autosampler
Full record, hazard data and enquiry for Autosampler for Gas Chromatography, 22-Position Tray →