Gas Chromatograph with Electronic Pneumatic Control, Split/Splitless Injector and FID
Bench gas chromatograph with electronic pneumatic control, a split and splitless injector and a flame ionisation detector, with a column oven programmable to 420 °C.
Typical applications
- Benzene series and BTEX (toluene, ethylbenzene, xylenes, styrene, cumene)
- Nitrobenzene compounds (nitrobenzene, dinitrotoluene)
- Chlorobenzene compounds (chlorobenzene, dichlorobenzene, trichlorobenzene)
- Total volatile organic compounds (TVOC)
- Phenolic compounds (phenol, cresol)
Add to enquiry
Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.
Worth knowing before you order
The base instrument is one split/splitless injector and one FID. The carrier gas is not supplied, and neither is the hydrogen and air the flame burns; the air source and flow-rate control device is listed as an option, and the column is not included at all. The computer is not supplied either - the catalogue states that the user must have a PC to run the software, and 99-ramp programming exists only there, against 20 ramps at the touch screen. The EPC flow, split ratio and inlet figures are quoted for nitrogen and helium only, so if hydrogen carrier is intended, get the EPC range for hydrogen confirmed in writing before ordering. Against the plainer capillary-injector model in this range, what this one buys is electronic pneumatic control, split/splitless injection, 420 °C instead of 400 °C and faster programmed heating. The manufacturer states the software is compatible with GLP and 21 CFR Part 11; Part 11 compliance is demonstrated by the user's validated process, not shipped with a machine.Specification
| Pneumatics | EPC, electronic pneumatic control |
|---|---|
| Sample introduction | Split / splitless injector, one fitted |
| Detector | FID, one fitted |
| FID detection limit | ≤8×10⁻¹² g/s (n-hexadecane) |
| FID drift and linearity | Drift ≤1.5×10⁻¹³ A/h; linearity range ≥10⁶ |
| EPC flow rate | 200 ml/min (N2), 1000 ml/min (He) |
| EPC flow accuracy and repeatability | ±5% accuracy; ±0.35% repeatability |
| Split ratio | 0-5000 (He), 0-1000 (N2) |
| Inlet and column oven temperature range | RT +7 °C to 420 °C, the oven in 1 °C increments |
| Oven temperature accuracy | ± 0.02 °C |
| Cooling time | 350 °C to 100 °C in ≤3 min; 400 °C to 50 °C in 8-10 min at 25 °C ambient |
| Programmed heating rate | 0.1 °C to 80 °C/min, in 1 °C increments |
| Program ramps | 20 ramps on the instrument, 99 ramps with the software |
| Oven size, inner / outer (L x W x H) | 284 x 280 x 241 mm / 340 x 345 x 281 mm |
| Display and control | 7 inch touch screen; built-in data acquisition and PC control, computer not supplied |
| Signal output | One analogue output |
| Power and supply | 2000 W; 220 V / 50 Hz |
| Packing size (L x W x H) and gross weight | 835 x 770 x 930 mm; 88 kg |
| Optional accessories | Autosampler; air source / flow-rate control device |
| HSN code | 90272000 |
Site preparation required
This instrument needs site work before delivery — typically a level grouted foundation, a dedicated power supply, and in some cases drainage or extraction. We issue the foundation drawing and utility schedule with the quotation so the civil work runs in parallel with the lead time.Support available
- Installation & commissioning
- Calibration
- Validation & qualification (IQ/OQ/PQ)
- Operator training
- Annual maintenance contract
- Spares & consumables
Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.
Related products
High Performance Liquid Chromatography System, Isocratic and Binary Gradient
High performance liquid chromatograph supplied as an isocratic single-pump or binary gradient twin-pump system with a UV detector and a manual six-port injection valve.
IndentSystem, isocratic build / gradient build: Isocratic, one pump / binary gradient, two pumps working in parallel
Specification for High Performance Liquid Chromatography System, Isocratic and Binary Gradient
Specification for High Performance Liquid Chromatography System, Isocratic and Binary Gradient System, isocratic build / gradient build Isocratic, one pump / binary gradient, two pumps working in parallel Pump delivery system Dual-plunger in series, floating plunger design; single-stroke discharged volume 30 ul Flow range 0.001 to 9.999 ml/min, in 0.001 ml/min increments Flow accuracy and precision ± 0.5 % or 10 µL/min; RSD ≤ 0.1% Pressure fluctuation ≤ 0.5% Pressure range ≤ 42 MPa with 316L pump head, ≤ 30 MPa with PEEK pump head Injector 7725i six-port manual valve Detector supplied UV; fluorescence and refractive index detectors offered as options Detection system 190-400 nm (700 nm optional), single or dual wavelength mode selectable Lamp Deuterium or halogen lamp (optional) selectable Wavelength increment, accuracy and precision 1 nm increment; accuracy 1 nm; precision ±0.1 nm Detector drift 2×10-4 AU 9 further specifications on the full record.
Typical applications
- Assay and related substances by HPLC
- Pharmaceutical quality control
- Food and beverage analysis
- Environmental sample analysis
- Method development
Also known as
- High performance liquid chromatograph
- Isocratic HPLC system
- Binary gradient HPLC system
- Liquid chromatography system
Gas Chromatograph with Capillary Injector and Flame Ionisation Detector
Bench gas chromatograph with a capillary injector, a single flame ionisation detector and a column oven programmable to 400 °C, operated from a PC.
IndentSample introduction: Capillary injector, one fitted
Specification for Gas Chromatograph with Capillary Injector and Flame Ionisation Detector
Specification for Gas Chromatograph with Capillary Injector and Flame Ionisation Detector Sample introduction Capillary injector, one fitted Detector FID, one fitted FID detection limit ≤3×10⁻¹² g/s FID drift ≤6×10⁻¹³ A/30 min FID linearity range ≥10⁶ Column oven temperature range RT +7 °C to 400 °C, in 1 °C increments Oven temperature accuracy ± 0.02 °C Cooling time 400 °C to 50 °C in 8-10 min at 25 °C ambient Programmed heating rate 0.1 °C to 40 °C/min, in 1 °C increments Program ramps 7 ramps standard on the instrument, up to 10 ramps with the software Column capacity One capillary column Oven size, inside / outside (L x W x H) 284 x 280 x 241 mm / 340 x 345 x 281 mm 10 further specifications on the full record.
Typical applications
- Benzene series and BTEX (toluene, ethylbenzene, xylenes, styrene, cumene)
- Nitrobenzene compounds (nitrobenzene, dinitrotoluene)
- Chlorobenzene compounds (chlorobenzene, dichlorobenzene, trichlorobenzene)
- Total volatile organic compounds (TVOC)
- Phenolic compounds (phenol, cresol)
Also known as
- Gas chromatograph
- GC-FID
- Capillary gas chromatograph
- Gas chromatography system
Autosampler for Gas Chromatography, 22-Position Tray
Automatic liquid sampler that injects from a 22-position tray into a gas chromatograph, for unattended sequences and repeatable injection volumes.
IndentInjector sizes: 1, 5, 10, 25, 50, 100, 250, 500 (µl)
Specification for Autosampler for Gas Chromatography, 22-Position Tray
Specification for Autosampler for Gas Chromatography, 22-Position Tray Injector sizes 1, 5, 10, 25, 50, 100, 250, 500 (µl) Sample tray 22 positions Positions, sample / solvent / waste 19 / 2 / 1 Sample size range 0.1 µl (with a 1 µl syringe) to 250 µl (with a 500 µl syringe) Sample injection times of each line 1 to 99 times Maximum interval 999 min Methods 1 to 20 Maximum injection inlets 1 Needle cleaning and sample pumping Up to 99 times each; maximum pumping interval 5000 ms Viscosity delay 0 to 60 s Dwell time before and after injection 0 to 120 s Needle speed Fast, slow, user-defined 9 further specifications on the full record.
Typical applications
- Unattended overnight GC sequences
- Routine QC batches
- Solvent wash and blank sequences
- Bar-coded sample tracking
Also known as
- GC autosampler
- Auto sampler for gas chromatograph
- Automatic liquid sampler
- Liquid autosampler
Full record, hazard data and enquiry for Autosampler for Gas Chromatography, 22-Position Tray →
Air Generator, 2000 mL/min
Bench air generator that delivers dry compressed air at up to 2000 mL/min and 0.4 MPa, as a replacement for cylinder air on flame detectors and other laboratory air services.
IndentMaximum flow: 2000 mL/min
Specification for Air Generator, 2000 mL/min
Specification for Air Generator, 2000 mL/min Maximum flow 2000 mL/min Output gas pressure 0.4 MPa Output purity Not printed in the catalogue - ask for it in writing Purification Phase process control with step-by-step gas condensation separation and purification Adsorbent Molecular sieve, regenerable Gas storage tank Stainless steel Pressure stabilisation Dual pressure stabilisation, high pressure resistance Sealing rings Silicone rubber, low sulphur content Colour-changing silica regeneration Heat at 120-140 °C until completely blue Output flow display LED Phase 1 phase Power wattage 180 W 6 further specifications on the full record.
Typical applications
- Air supply to flame ionisation detectors
- Air supply to flame photometric and nitrogen-phosphorus detectors
- General instrument air on the bench
Also known as
- Air generator
- Laboratory air generator
- Compressed air generator
- Air source for GC
- FID air supply