Autosampler for Gas Chromatography, 22-Position Tray
Automatic liquid sampler that injects from a 22-position tray into a gas chromatograph, for unattended sequences and repeatable injection volumes.
Typical applications
- Unattended overnight GC sequences
- Routine QC batches
- Solvent wash and blank sequences
- Bar-coded sample tracking
Add to enquiry
Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.
Worth knowing before you order
The tray is 22 positions in total and the catalogue splits it as 19 sample vials, two solvent vials and one waste vial - the usable sample count is 19, not 22. Syringes are sized against the injection volume (0.1 µl needs a 1 µl syringe, 250 µl needs a 500 µl syringe) and are consumables, so confirm which syringe and which vials and septa are in the quotation. Control is through the gas chromatograph software over one of several I/O modes, so the connection has to be checked against the specific chromatograph before ordering rather than assumed.Specification
| Injector sizes | 1, 5, 10, 25, 50, 100, 250, 500 (µl) |
|---|---|
| Sample tray | 22 positions |
| Positions, sample / solvent / waste | 19 / 2 / 1 |
| Sample size range | 0.1 µl (with a 1 µl syringe) to 250 µl (with a 500 µl syringe) |
| Sample injection times of each line | 1 to 99 times |
| Maximum interval | 999 min |
| Methods | 1 to 20 |
| Maximum injection inlets | 1 |
| Needle cleaning and sample pumping | Up to 99 times each; maximum pumping interval 5000 ms |
| Viscosity delay | 0 to 60 s |
| Dwell time before and after injection | 0 to 120 s |
| Needle speed | Fast, slow, user-defined |
| Sample extract and injection speed | Fast, slow, user-defined |
| Injection mode | Normal mode, continuity mode |
| Control mode | GC software control |
| Interface | 5 inch touch screen; MODBUS protocol and USB; bar-code scanning and sample temperature control supported |
| Synchronous sampling time reproducibility | Less than 1/1000 s |
| Power supply | AC 220V / 50-60Hz |
| Packing dimension (LxWxH) and gross weight | 620 x 325 x 280 mm; 6 kg |
| HSN code | 90272000 |
Support available
- Installation & commissioning
- Calibration
- Operator training
- Annual maintenance contract
- Spares & consumables
Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.
Related products
High Performance Liquid Chromatography System, Isocratic and Binary Gradient
High performance liquid chromatograph supplied as an isocratic single-pump or binary gradient twin-pump system with a UV detector and a manual six-port injection valve.
IndentSystem, isocratic build / gradient build: Isocratic, one pump / binary gradient, two pumps working in parallel
Specification for High Performance Liquid Chromatography System, Isocratic and Binary Gradient
Specification for High Performance Liquid Chromatography System, Isocratic and Binary Gradient System, isocratic build / gradient build Isocratic, one pump / binary gradient, two pumps working in parallel Pump delivery system Dual-plunger in series, floating plunger design; single-stroke discharged volume 30 ul Flow range 0.001 to 9.999 ml/min, in 0.001 ml/min increments Flow accuracy and precision ± 0.5 % or 10 µL/min; RSD ≤ 0.1% Pressure fluctuation ≤ 0.5% Pressure range ≤ 42 MPa with 316L pump head, ≤ 30 MPa with PEEK pump head Injector 7725i six-port manual valve Detector supplied UV; fluorescence and refractive index detectors offered as options Detection system 190-400 nm (700 nm optional), single or dual wavelength mode selectable Lamp Deuterium or halogen lamp (optional) selectable Wavelength increment, accuracy and precision 1 nm increment; accuracy 1 nm; precision ±0.1 nm Detector drift 2×10-4 AU 9 further specifications on the full record.
Typical applications
- Assay and related substances by HPLC
- Pharmaceutical quality control
- Food and beverage analysis
- Environmental sample analysis
- Method development
Also known as
- High performance liquid chromatograph
- Isocratic HPLC system
- Binary gradient HPLC system
- Liquid chromatography system
Gas Chromatograph with Capillary Injector and Flame Ionisation Detector
Bench gas chromatograph with a capillary injector, a single flame ionisation detector and a column oven programmable to 400 °C, operated from a PC.
IndentSample introduction: Capillary injector, one fitted
Specification for Gas Chromatograph with Capillary Injector and Flame Ionisation Detector
Specification for Gas Chromatograph with Capillary Injector and Flame Ionisation Detector Sample introduction Capillary injector, one fitted Detector FID, one fitted FID detection limit ≤3×10⁻¹² g/s FID drift ≤6×10⁻¹³ A/30 min FID linearity range ≥10⁶ Column oven temperature range RT +7 °C to 400 °C, in 1 °C increments Oven temperature accuracy ± 0.02 °C Cooling time 400 °C to 50 °C in 8-10 min at 25 °C ambient Programmed heating rate 0.1 °C to 40 °C/min, in 1 °C increments Program ramps 7 ramps standard on the instrument, up to 10 ramps with the software Column capacity One capillary column Oven size, inside / outside (L x W x H) 284 x 280 x 241 mm / 340 x 345 x 281 mm 10 further specifications on the full record.
Typical applications
- Benzene series and BTEX (toluene, ethylbenzene, xylenes, styrene, cumene)
- Nitrobenzene compounds (nitrobenzene, dinitrotoluene)
- Chlorobenzene compounds (chlorobenzene, dichlorobenzene, trichlorobenzene)
- Total volatile organic compounds (TVOC)
- Phenolic compounds (phenol, cresol)
Also known as
- Gas chromatograph
- GC-FID
- Capillary gas chromatograph
- Gas chromatography system
Gas Chromatograph with Electronic Pneumatic Control, Split/Splitless Injector and FID
Bench gas chromatograph with electronic pneumatic control, a split and splitless injector and a flame ionisation detector, with a column oven programmable to 420 °C.
IndentPneumatics: EPC, electronic pneumatic control
Specification for Gas Chromatograph with Electronic Pneumatic Control, Split/Splitless Injector and FID
Specification for Gas Chromatograph with Electronic Pneumatic Control, Split/Splitless Injector and FID Pneumatics EPC, electronic pneumatic control Sample introduction Split / splitless injector, one fitted Detector FID, one fitted FID detection limit ≤8×10⁻¹² g/s (n-hexadecane) FID drift and linearity Drift ≤1.5×10⁻¹³ A/h; linearity range ≥10⁶ EPC flow rate 200 ml/min (N2), 1000 ml/min (He) EPC flow accuracy and repeatability ±5% accuracy; ±0.35% repeatability Split ratio 0-5000 (He), 0-1000 (N2) Inlet and column oven temperature range RT +7 °C to 420 °C, the oven in 1 °C increments Oven temperature accuracy ± 0.02 °C Cooling time 350 °C to 100 °C in ≤3 min; 400 °C to 50 °C in 8-10 min at 25 °C ambient Programmed heating rate 0.1 °C to 80 °C/min, in 1 °C increments 10 further specifications on the full record.
Typical applications
- Benzene series and BTEX (toluene, ethylbenzene, xylenes, styrene, cumene)
- Nitrobenzene compounds (nitrobenzene, dinitrotoluene)
- Chlorobenzene compounds (chlorobenzene, dichlorobenzene, trichlorobenzene)
- Total volatile organic compounds (TVOC)
- Phenolic compounds (phenol, cresol)
Also known as
- Gas chromatograph
- GC-FID
- EPC gas chromatograph
- Split splitless gas chromatograph
Air Generator, 2000 mL/min
Bench air generator that delivers dry compressed air at up to 2000 mL/min and 0.4 MPa, as a replacement for cylinder air on flame detectors and other laboratory air services.
IndentMaximum flow: 2000 mL/min
Specification for Air Generator, 2000 mL/min
Specification for Air Generator, 2000 mL/min Maximum flow 2000 mL/min Output gas pressure 0.4 MPa Output purity Not printed in the catalogue - ask for it in writing Purification Phase process control with step-by-step gas condensation separation and purification Adsorbent Molecular sieve, regenerable Gas storage tank Stainless steel Pressure stabilisation Dual pressure stabilisation, high pressure resistance Sealing rings Silicone rubber, low sulphur content Colour-changing silica regeneration Heat at 120-140 °C until completely blue Output flow display LED Phase 1 phase Power wattage 180 W 6 further specifications on the full record.
Typical applications
- Air supply to flame ionisation detectors
- Air supply to flame photometric and nitrogen-phosphorus detectors
- General instrument air on the bench
Also known as
- Air generator
- Laboratory air generator
- Compressed air generator
- Air source for GC
- FID air supply
Full record, hazard data and enquiry for Air Generator, 2000 mL/min →