Gas Chromatograph with Capillary Injector and Flame Ionisation Detector

Bench gas chromatograph with a capillary injector, a single flame ionisation detector and a column oven programmable to 400 °C, operated from a PC.

Typical applications

  • Benzene series and BTEX (toluene, ethylbenzene, xylenes, styrene, cumene)
  • Nitrobenzene compounds (nitrobenzene, dinitrotoluene)
  • Chlorobenzene compounds (chlorobenzene, dichlorobenzene, trichlorobenzene)
  • Total volatile organic compounds (TVOC)
  • Phenolic compounds (phenol, cresol)

Add to enquiry

Enquire on WhatsApp

Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.

Worth knowing before you order

The base instrument is one capillary injector and one FID, and nothing else. The carrier gas is not supplied, and neither are the hydrogen and air the flame needs - cylinders with regulators, or generators, have to be costed alongside the instrument, and the air source and flow-rate control device the catalogue lists is a separate line item. The column is not included. Nor is the computer: the catalogue states plainly that the user must provide a PC to run the control software, and the oven programming beyond seven ramps exists only in that software. Note the internal contradiction in the catalogue - the feature page claims 10 ramps, the specification table gives 7 on the instrument and up to 10 with the software; quote against the table. Headspace or thermal desorption sampling, where the method needs it, is a further separate item. The manufacturer states the software is compatible with GLP and 21 CFR Part 11; Part 11 compliance rests on the user's validated process, not on anything shipped with the machine.

Specification

Technical specification for Gas Chromatograph with Capillary Injector and Flame Ionisation Detector
Sample introductionCapillary injector, one fitted
DetectorFID, one fitted
FID detection limit≤3×10⁻¹² g/s
FID drift≤6×10⁻¹³ A/30 min
FID linearity range≥10⁶
Column oven temperature rangeRT +7 °C to 400 °C, in 1 °C increments
Oven temperature accuracy± 0.02 °C
Cooling time400 °C to 50 °C in 8-10 min at 25 °C ambient
Programmed heating rate0.1 °C to 40 °C/min, in 1 °C increments
Program ramps7 ramps standard on the instrument, up to 10 ramps with the software
Column capacityOne capillary column
Oven size, inside / outside (L x W x H)284 x 280 x 241 mm / 340 x 345 x 281 mm
Signal outputOne analogue output
ControlBuilt-in data acquisition with real-time status monitoring and PC control; computer not supplied
Oven cool-downQuick heat-up and rapid cool-down with automated back-door opening
Power and supply2000 W; 220 V / 50 Hz
Packing size (L x W x H)830 x 680 x 855 mm
Gross weight79 kg
Optional accessoriesAutosampler; air source / flow-rate control device
HSN code90272000

Site preparation required

This instrument needs site work before delivery — typically a level grouted foundation, a dedicated power supply, and in some cases drainage or extraction. We issue the foundation drawing and utility schedule with the quotation so the civil work runs in parallel with the lead time.

Support available

  • Installation & commissioning
  • Calibration
  • Validation & qualification (IQ/OQ/PQ)
  • Operator training
  • Annual maintenance contract
  • Spares & consumables

Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.