ELISA Microplate Reader, 96-Well
Filter photometer that measures absorbance in 96-well microplates for enzyme-linked immunosorbent assays and other colorimetric endpoint assays.
Typical applications
- Quantitative ELISA against a standard curve
- Qualitative and semi-quantitative immunoassay
- Colorimetric endpoint assays in 96-well plates
- Protein and total-nucleic-acid colorimetric kits read at fixed wavelengths
Add to enquiry
Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.
Worth knowing before you order
A plate reader is only usable with the wavelengths your assay kit specifies. Every kit insert names a read wavelength and usually a reference wavelength, and if that pair is not in the filter wheel the kit simply cannot be run on this instrument. Four filters are fitted — 405, 450, 492 and 630 nm, which between them cover the common TMB, pNPP and OPD endpoints and the usual reference read — and the wheel takes eight, so send us the insert for every kit you intend to run and we will confirm the filter set before the order is placed; additional filters within 340 to 750 nm are quoted separately. The catalogue's performance table is not legible in this scan, so photometric accuracy, repeatability, linearity and plate read time are deliberately absent above — ask for them in writing if the work is quantitative. Note also what this instrument does not do: it reads absorbance only, it does not wash or incubate plates.Specification
| Plate format | 96-well microplates |
|---|---|
| Measurement | Absorbance, by fixed-wavelength filter system |
| Absorbance range | 0 to 4.000 Abs |
| Light source | Halogen lamp; lamp and filters are both easy to replace |
| Filter wheel | 8 positions, covering 340 nm to 750 nm |
| Filters supplied | 4 — 405 nm, 450 nm, 492 nm, 630 nm |
| Filters, maximum | Up to 8 can be loaded; the further 4 are optional |
| Calibration | Automatic calibration and positioning system |
| Diagnostics | Self-check of the optical path and of mechanical motion |
| Plate shaking | Built-in vibration plate, adjustable time and speed |
| Display | 7 inch colour touch screen, HD |
| Operating system | Android |
| On-board software | Instrument control and data analysis: wavelength and absorbance pre-processing, microplate layout, well type, standard curve and test report |
| Data port | USB |
| Supplied with | Main instrument, power cord, instruction manual, test certificate |
Support available
- Installation & commissioning
- Calibration
- Validation & qualification (IQ/OQ/PQ)
- Operator training
- Annual maintenance contract
- Spares & consumables
Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.
Related products
Blue Light Transilluminator, 470 nm
Blue-light gel viewer and cutting station for observing stained nucleic acid and protein bands in a gel, for photography or for excising a band.
IndentExcitation wavelength: 470 nm blue light
Specification for Blue Light Transilluminator, 470 nm
Specification for Blue Light Transilluminator, 470 nm Excitation wavelength 470 nm blue light Light source LED array, double-sided lighting in the matrix body Light intensity Adjustable Maximum gel size 100 x 150 mm Observation surface 70 x 130 mm Observation surface material Glass plate, cut gels directly on it LED life 10,000 hrs Dye compatibility Most conventional nucleic acid and protein stains Power supply DC 24 V adaptor, run from 220 V, 50/60 Hz mains Packing dimensions (L x W x H) 210 x 215 x 50 mm Supplied with Main instrument, power adaptor, cutter, instruction manual, test certificate Services Installation & commissioning · Operator training · Spares & consumables Typical applications
- Viewing stained DNA and RNA gels
- Viewing stained protein gels
- Excising bands for gel extraction
- Gel photography
Also known as
- Blue light gel cutter
- Blue LED transilluminator
- Safe gel viewer
- Gel cutting box
Full record, hazard data and enquiry for Blue Light Transilluminator, 470 nm →
Nucleic Acid Extractor, 32 Samples (DNA and RNA)
Automated magnetic-bead workstation that lyses, binds, washes and elutes DNA or RNA from up to 32 samples in one unattended run.
IndentSamples per run: 1 to 32
Specification for Nucleic Acid Extractor, 32 Samples (DNA and RNA)
Specification for Nucleic Acid Extractor, 32 Samples (DNA and RNA) Samples per run 1 to 32 Sample volume range 50 to 1000 µl Separation principle Nucleic acid adsorbed on magnetic beads, then transferred, washed and eluted by magnetic rods Mixing Magnetic rod sleeve motion; vibration amplitude adjusts automatically to the solution volume Rod drive Stepper motor with ball screw transmission; position protection on each moving part Small-volume elution Strong absorption mode holds the beads at the rod head so a small elution volume still covers them Purification precision CV < 3% DNA recovery > 95% Positive detection rate > 95% Sample types Blood, tissue, cells Display 10.1 inch touch screen Programme memory 1,000 programmes; edit, save and delete on the instrument 4 further specifications on the full record.
Typical applications
- DNA and RNA extraction from whole blood
- Extraction from tissue
- Extraction from cultured cells
- Template preparation for PCR and qPCR
- Molecular diagnostic sample preparation
Also known as
- DNA extractor
- RNA extractor
- Automated nucleic acid purification system
- Magnetic bead extraction system
Full record, hazard data and enquiry for Nucleic Acid Extractor, 32 Samples (DNA and RNA) →
Hybridisation Oven with Tube Rotation and Shaking Base
Hot-air convection oven that rotates hybridisation tubes at a held temperature for blot and membrane hybridisation, with a shaking platform in the base of the chamber.
IndentHeating: Hot air constant-temperature convection with an internal air circulation device
Specification for Hybridisation Oven with Tube Rotation and Shaking Base
Specification for Hybridisation Oven with Tube Rotation and Shaking Base Heating Hot air constant-temperature convection with an internal air circulation device Control Microchip control, with simple calibration and an auto-tuning function Display Touch screen with real-time temperature display Temperature record Temperature curve waveform recording real-time status Programming 5-segment programme combination, so a multi-step protocol runs without manual resetting Memory 50 sets of data Agitation Tube rotation, plus shaking at the base of the chamber Tube handling Hybridisation tubes load and unload without tools Chamber Stainless steel, corrosion resistant Door Double glass door Supplied with Main instrument, standard hybridisation tube, instruction manual, test certificate Services Installation & commissioning · Calibration · Operator training · Annual maintenance contract · Spares & consumables Typical applications
- Southern blot hybridisation
- Northern blot hybridisation
- Membrane pre-hybridisation and stringency washing
- Colony and plaque hybridisation
Also known as
- Hybridization oven
- Hyb oven
- Rotisserie hybridisation incubator
- Blot hybridisation oven
Full record, hazard data and enquiry for Hybridisation Oven with Tube Rotation and Shaking Base →
UV Crosslinker, 254 nm
Enclosed 254 nm ultraviolet chamber that fixes nucleic acid to hybridisation membranes under measured energy or timed control, and decontaminates PCR consumables.
IndentUV wavelength: 254 nm
Specification for UV Crosslinker, 254 nm
Specification for UV Crosslinker, 254 nm UV wavelength 254 nm Wavelength, optional 365 nm, 312 nm Energy measurement range 0 to 99.99 J/cm² Maximum UV radiation energy 5 mW/cm² Maximum irradiation area 880 cm² Lamps 6 pcs x 8 W light tubes Operating modes UV energy mode, time mode Stored settings 50 groups of energies and times can be set and saved Control Microprocessor with a time integrator that monitors irradiation continuously and stops the lamps at the set energy Display 7 inch touch screen Safety interlock UV safety window and safety door lock; the instrument stops working automatically when the door is opened Chamber Stainless steel 7 further specifications on the full record.
Typical applications
- Cross-linking and fixing nucleic acids on hybridisation membranes
- UV sterilisation to eliminate PCR contamination
- DNA cutting in agarose gels
- RecA mutation screening
- Partial restriction endonuclease digestion of pyrimidine dimers
- UV treatment of polymers
Also known as
- UV cross-linker
- DNA crosslinker
- Membrane crosslinker
- UV crosslinking oven
Full record, hazard data and enquiry for UV Crosslinker, 254 nm →