Molecular Biology
Thermal cyclers, nucleic acid extraction, transilluminators, crosslinkers, hybridisation ovens and microplate instruments.
20 categories · 244 published records. The catalogue we can supply is broader than the catalogue we publish — send us the item if you cannot find it.
Before you order
Two practical cautions for this bench. Ultraviolet transilluminators damage both DNA and the operator: a blue-light unit removes the eye and skin exposure and stops the strand breaks that make downstream cloning fail, and it is the right default unless a stain you are committed to needs UV. And a microplate reader is only as good as its filter or monochromator set — a reader quoted without the wavelengths your assay kit specifies will need an accessory order before it can run anything, so send the kit insert with your enquiry.
7 records
Cannot find it? Ask on WhatsApp →Blue Light Transilluminator, 470 nm
Blue-light gel viewer and cutting station for observing stained nucleic acid and protein bands in a gel, for photography or for excising a band.
IndentExcitation wavelength: 470 nm blue light
Specification for Blue Light Transilluminator, 470 nm
Specification for Blue Light Transilluminator, 470 nm Excitation wavelength 470 nm blue light Light source LED array, double-sided lighting in the matrix body Light intensity Adjustable Maximum gel size 100 x 150 mm Observation surface 70 x 130 mm Observation surface material Glass plate, cut gels directly on it LED life 10,000 hrs Dye compatibility Most conventional nucleic acid and protein stains Power supply DC 24 V adaptor, run from 220 V, 50/60 Hz mains Packing dimensions (L x W x H) 210 x 215 x 50 mm Supplied with Main instrument, power adaptor, cutter, instruction manual, test certificate Services Installation & commissioning · Operator training · Spares & consumables Typical applications
- Viewing stained DNA and RNA gels
- Viewing stained protein gels
- Excising bands for gel extraction
- Gel photography
Also known as
- Blue light gel cutter
- Blue LED transilluminator
- Safe gel viewer
- Gel cutting box
Full record, hazard data and enquiry for Blue Light Transilluminator, 470 nm →
Nucleic Acid Extractor, 32 Samples (DNA and RNA)
Automated magnetic-bead workstation that lyses, binds, washes and elutes DNA or RNA from up to 32 samples in one unattended run.
IndentSamples per run: 1 to 32
Specification for Nucleic Acid Extractor, 32 Samples (DNA and RNA)
Specification for Nucleic Acid Extractor, 32 Samples (DNA and RNA) Samples per run 1 to 32 Sample volume range 50 to 1000 µl Separation principle Nucleic acid adsorbed on magnetic beads, then transferred, washed and eluted by magnetic rods Mixing Magnetic rod sleeve motion; vibration amplitude adjusts automatically to the solution volume Rod drive Stepper motor with ball screw transmission; position protection on each moving part Small-volume elution Strong absorption mode holds the beads at the rod head so a small elution volume still covers them Purification precision CV < 3% DNA recovery > 95% Positive detection rate > 95% Sample types Blood, tissue, cells Display 10.1 inch touch screen Programme memory 1,000 programmes; edit, save and delete on the instrument 4 further specifications on the full record.
Typical applications
- DNA and RNA extraction from whole blood
- Extraction from tissue
- Extraction from cultured cells
- Template preparation for PCR and qPCR
- Molecular diagnostic sample preparation
Also known as
- DNA extractor
- RNA extractor
- Automated nucleic acid purification system
- Magnetic bead extraction system
Full record, hazard data and enquiry for Nucleic Acid Extractor, 32 Samples (DNA and RNA) →
Hybridisation Oven with Tube Rotation and Shaking Base
Hot-air convection oven that rotates hybridisation tubes at a held temperature for blot and membrane hybridisation, with a shaking platform in the base of the chamber.
IndentHeating: Hot air constant-temperature convection with an internal air circulation device
Specification for Hybridisation Oven with Tube Rotation and Shaking Base
Specification for Hybridisation Oven with Tube Rotation and Shaking Base Heating Hot air constant-temperature convection with an internal air circulation device Control Microchip control, with simple calibration and an auto-tuning function Display Touch screen with real-time temperature display Temperature record Temperature curve waveform recording real-time status Programming 5-segment programme combination, so a multi-step protocol runs without manual resetting Memory 50 sets of data Agitation Tube rotation, plus shaking at the base of the chamber Tube handling Hybridisation tubes load and unload without tools Chamber Stainless steel, corrosion resistant Door Double glass door Supplied with Main instrument, standard hybridisation tube, instruction manual, test certificate Services Installation & commissioning · Calibration · Operator training · Annual maintenance contract · Spares & consumables Typical applications
- Southern blot hybridisation
- Northern blot hybridisation
- Membrane pre-hybridisation and stringency washing
- Colony and plaque hybridisation
Also known as
- Hybridization oven
- Hyb oven
- Rotisserie hybridisation incubator
- Blot hybridisation oven
Full record, hazard data and enquiry for Hybridisation Oven with Tube Rotation and Shaking Base →
UV Crosslinker, 254 nm
Enclosed 254 nm ultraviolet chamber that fixes nucleic acid to hybridisation membranes under measured energy or timed control, and decontaminates PCR consumables.
IndentUV wavelength: 254 nm
Specification for UV Crosslinker, 254 nm
Specification for UV Crosslinker, 254 nm UV wavelength 254 nm Wavelength, optional 365 nm, 312 nm Energy measurement range 0 to 99.99 J/cm² Maximum UV radiation energy 5 mW/cm² Maximum irradiation area 880 cm² Lamps 6 pcs x 8 W light tubes Operating modes UV energy mode, time mode Stored settings 50 groups of energies and times can be set and saved Control Microprocessor with a time integrator that monitors irradiation continuously and stops the lamps at the set energy Display 7 inch touch screen Safety interlock UV safety window and safety door lock; the instrument stops working automatically when the door is opened Chamber Stainless steel 7 further specifications on the full record.
Typical applications
- Cross-linking and fixing nucleic acids on hybridisation membranes
- UV sterilisation to eliminate PCR contamination
- DNA cutting in agarose gels
- RecA mutation screening
- Partial restriction endonuclease digestion of pyrimidine dimers
- UV treatment of polymers
Also known as
- UV cross-linker
- DNA crosslinker
- Membrane crosslinker
- UV crosslinking oven
Full record, hazard data and enquiry for UV Crosslinker, 254 nm →
ELISA Microplate Reader, 96-Well
Filter photometer that measures absorbance in 96-well microplates for enzyme-linked immunosorbent assays and other colorimetric endpoint assays.
IndentPlate format: 96-well microplates
Specification for ELISA Microplate Reader, 96-Well
Specification for ELISA Microplate Reader, 96-Well Plate format 96-well microplates Measurement Absorbance, by fixed-wavelength filter system Absorbance range 0 to 4.000 Abs Light source Halogen lamp; lamp and filters are both easy to replace Filter wheel 8 positions, covering 340 nm to 750 nm Filters supplied 4 — 405 nm, 450 nm, 492 nm, 630 nm Filters, maximum Up to 8 can be loaded; the further 4 are optional Calibration Automatic calibration and positioning system Diagnostics Self-check of the optical path and of mechanical motion Plate shaking Built-in vibration plate, adjustable time and speed Display 7 inch colour touch screen, HD Operating system Android 4 further specifications on the full record.
Typical applications
- Quantitative ELISA against a standard curve
- Qualitative and semi-quantitative immunoassay
- Colorimetric endpoint assays in 96-well plates
- Protein and total-nucleic-acid colorimetric kits read at fixed wavelengths
Also known as
- ELISA reader
- Microplate photometer
- Absorbance microplate reader
- 96-well plate reader
Full record, hazard data and enquiry for ELISA Microplate Reader, 96-Well →
Gradient PCR Thermal Cycler, 96-Well
Gradient thermal cycler for amplifying DNA and RNA, running a row of different annealing temperatures across the block so a primer pair can be optimised in one run.
IndentBlock format: 96-well, from the model designation and the 96-position plate layout shown on the instrument screen
Specification for Gradient PCR Thermal Cycler, 96-Well
Specification for Gradient PCR Thermal Cycler, 96-Well Block format 96-well, from the model designation and the 96-position plate layout shown on the instrument screen Maximum ramping rate 6 °C/s Run modes Standard and gradient, selected per programme file Hot lid Temperature and work mode both settable, to suit different experiments Display 10.1 inch touch screen, graphical menu navigation Operating system Android Programming Built-in standard programme templates for quick file editing; on-instrument file library Incubation One-click quick incubation function Power failure recovery Automatic restart; an unfinished programme continues when power is restored Connectivity Wi-Fi Data port USB, for storing and copying PCR data and for a USB mouse Screen lock Available 3 further specifications on the full record.
Typical applications
- End-point PCR
- Annealing temperature optimisation
- Gene expression analysis
- Genotyping
- Pathogen detection
- Template preparation for DNA sequencing
Also known as
- PCR machine
- Thermal cycler
- Gradient thermocycler
- DNA amplifier
Full record, hazard data and enquiry for Gradient PCR Thermal Cycler, 96-Well →
Automatic ELISA Plate Washer
Automatic microplate washer that dispenses, soaks and aspirates wash buffer a whole plate or a row at a time, to clear unbound reagent between ELISA incubation steps.
IndentProcess modes: Full plate wash, row by row wash
Specification for Automatic ELISA Plate Washer
Specification for Automatic ELISA Plate Washer Process modes Full plate wash, row by row wash Wash head 8 channel or 12 channel cleaning head Residual liquid volume < 1.5 µl Residual liquid clearing Dedicated residual liquid cleaning function Injection accuracy < 2% at 300 µl Soaking time 1 s to 99 min Liquid pump type Diaphragm pump Well shapes accepted Flat bottom, U-shaped, V-shaped and C-shaped wells Display 4.3 inch colour touch screen Packing dimensions (L x W x H) 453 x 388 x 155 mm Gross weight 14 kg Supplied with Main instrument, washing head, wash bottles, power cord, instruction manual, test certificate 1 further specification on the full record.
Typical applications
- Wash steps in manual and semi-automated ELISA
- Removing unbound antigen, antibody and conjugate between incubations
- Soak steps in immunoassay protocols
Also known as
- Microplate washer
- ELISA washer
- Plate washer
- 96-well plate washer
Full record, hazard data and enquiry for Automatic ELISA Plate Washer →
What laboratories usually order alongside this.
Microbiology & Sterilisation
Autoclaves, laminar air flow cabinets, BOD and bacteriological incubators, colony counters and aseptic handling equipment.
Spectroscopy
UV-visible and visible spectrophotometers, from single-beam teaching instruments to double-beam and PMT-detector research models.
Dehydrated Culture Media
Agars, broths, bases and supplements for isolation, enumeration and identification, including pharmacopoeial formulations and vegetable-peptone media free of animal-origin raw material.
Why we publish the standard revision, not just the number.
Testing instruments are bought against a method, and a method is written against a standard. When that standard is revised, the old number stays in circulation for years — sometimes decades — because catalogues copy each other and nobody re-checks.
Three examples currently live across this industry: ASTM D1559 for Marshall stability, withdrawn in 1998. ASTM D422 for hydrometer analysis, withdrawn in 2016. IS 13311 for non-destructive concrete testing, absorbed into the IS 516 family in 2018. All three still appear on product listings you can buy from today.
That matters commercially, not just pedantically. If your quality manual cites a withdrawn standard, a NABL assessor will raise it, and the fastest way that error enters a manual is by being copied off a supplier’s specification sheet.
On qualification: for pharmaceutical customers, the documentation is half the purchase. GMP-specification equipment differs in its contact surfaces, its control system, its printed cycle records and its IQ/OQ/PQ protocol set. Specify that requirement at enquiry stage — retrofitting it after installation costs more and delays qualification.
On site preparation: compression testing machines, ductility baths, abrasion machines and large ovens need foundations, three-phase supply, drainage or extraction. We issue the foundation drawing and utility schedule with the quotation so the civil work can run in parallel with the delivery lead time rather than after it.