Laboratory Freeze Dryer (Lyophiliser), −60 °C and −80 °C Condenser

Bench freeze dryer that removes water from frozen material by sublimation under vacuum, offered with a −60 °C or −80 °C condenser and in tray, manifold and vial-stoppering configurations.

Typical applications

  • Freeze drying of biological samples
  • Lyophilisation of pharmaceutical formulations
  • Preservation of microbial cultures
  • Drying of heat-sensitive plant and food extracts
  • Preparing samples for long-term storage

Add to enquiry

Enquire on WhatsApp

Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.

Worth knowing before you order

Two decisions separate these six models and both cost money to get wrong. First, the condenser: the catalogue states −60 °C suits samples in ordinary aqueous solvents and −80 °C is for samples containing low-freezing-point substances, so an ethanol or acetonitrile matrix points to an −80 °C machine. Second, the sample interface: a plain tray unit dries in bulk, a manifold unit takes round-bottom flasks, and a stoppering unit closes vials under vacuum inside the chamber before the door is opened — you cannot add stoppering later. Note also that the three-tray versions have the smaller 0.094 m² drying area because the third tray position is given up to the stopper or manifold hardware. The rotary vane pump is oil-lubricated, so pump oil and the oil mist filter are recurring costs. The stated 15–25 °C ambient and ≤ 70% relative humidity are real siting constraints, not a formality: a hot or humid room will cost condenser performance.

Specification

Technical specification for Laboratory Freeze Dryer (Lyophiliser), −60 °C and −80 °C Condenser
Condenser temperature−60 °C (LMFD61, LMFD62, LMFD63, LMFD64) or −80 °C (LMFD83, LMFD84)
Refrigeration systemSingle cascade on the −60 °C models; dual cascade on the −80 °C models
Freeze-drying area0.12 m² on LMFD61, LMFD63, LMFD83; 0.094 m² on LMFD62, LMFD64, LMFD84
Trays200 mm × 4 (LMFD61, LMFD63, LMFD83) or 200 mm × 3 (LMFD62, LMFD64, LMFD84)
Tray spacing70 mm
ConfigurationPlain (LMFD61); with stopper (LMFD62); with manifold (LMFD63, LMFD83); manifold and stopper (LMFD64, LMFD84)
Vacuum pressure< 5 Pa on LMFD61 and LMFD62; < 10 Pa on LMFD63, LMFD64, LMFD83, LMFD84
Ice condenser capacity3 L / 24 h
DefrostHeating coil
Display7 in touch screen showing condenser temperature, sample temperature and vacuum, with graph
Ambient temperature required15 °C to 25 °C
Relative humidity required≤ 70%
Vacuum pumpStandard supply — double-stage oil-lubricated rotary vane
Vacuum pump speed / oil capacity1400 rpm / 0.8 litre
Vacuum pump noise / weight54 dB / 25 kg
Power950 W
Power supply220–240 V / 50 Hz
Instrument dimensions (L x W x H)393 x 500 x 450 mm, without chamber
Total gross weight, three wooden boxes102 kg / 111 kg / 111 kg / 120 kg / 144 kg / 150 kg for LMFD61 / 62 / 63 / 64 / 83 / 84

Support available

  • Installation & commissioning
  • Calibration
  • Validation & qualification (IQ/OQ/PQ)
  • Operator training
  • Annual maintenance contract
  • Spares & consumables

Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.