Sample Preparation & Mixing
Magnetic and overhead stirrers, hotplates, vortex and tube mixers, homogenisers, sonicators, ultrasonic cleaners, rotary evaporators and digestion systems.
20 categories · 244 published records. The catalogue we can supply is broader than the catalogue we publish — send us the item if you cannot find it.
Before you order
The distinction that gets missed here is between an ultrasonic cleaner and a probe sonicator. A bath cleans glassware and degasses solvent; it will not lyse cells or disperse a nanoparticle suspension, because the energy is spread through the whole tank. A probe delivers that energy into the sample and will do the disruption — and will also heat the sample, foam protein and need an ice bath and a hearing-protected space. They are not substitutes at any price. Same logic for stirring: a magnetic follower slips in anything viscous, which is where an overhead stirrer starts.
26 records · page 1 of 2
Cannot find it? Ask on WhatsApp →Dispensing Peristaltic Pump, 0.005 to 641 mL/min
Tube-driven pump that meters and transfers liquid without the liquid ever touching the pump, for dispensing, feeding and quantitative transfer duties.
IndentFlow range: 0.005 to 641 mL/min
Specification for Dispensing Peristaltic Pump, 0.005 to 641 mL/min
Specification for Dispensing Peristaltic Pump, 0.005 to 641 mL/min Flow range 0.005 to 641 mL/min Speed range 0.1 to 150 rpm Speed resolution 0.1 rpm at or below 100 rpm; 1 rpm above 100 rpm Speed accuracy < ±0.2 % Pump heads / channels 1 Standard tube 18# Flow at 150 rpm, by tube 13# 7.5, 14# 30, 19# 75, 16# 120, 25# 285, 17# 450, 18# 641 mL/min Flow at 0.1 rpm, by tube 13# 0.0050, 14# 0.020, 19# 0.05, 16# 0.080, 25# 0.19, 17# 0.30, 18# 0.43 mL/min Control functions Start and stop, reversible direction, full speed, speed adjustment, power-down state memory Timer and delay start / stop Available External control External analogue speed regulation and external start/stop and direction signals, 5 to 24 V, physically isolated; voltage or current signal type selectable from the panel Communication interface RS485, MODBUS protocol 12 further specifications on the full record.
Typical applications
- Bacterial and cell culture feed
- Animal heart perfusion
- Liquid addition to synthetic reactions
- Tangential flow ultrafiltration
- Coating and granulation liquid supply
- Laboratory dispensing and quantitative transfer
Also known as
- Peristaltic pump
- Dosing pump
- Tubing pump
- Liquid transfer pump
- Dispensing pump
Full record, hazard data and enquiry for Dispensing Peristaltic Pump, 0.005 to 641 mL/min →
Rotary Evaporator, 1 L Flask, Motorised Lift
Motorised rotary evaporator that strips solvent from a 1 L flask under reduced pressure on a heated bath, with a vertical condenser and a separate collection bottle.
IndentEvaporation capacity (water): Max. 25 mL/min
Specification for Rotary Evaporator, 1 L Flask, Motorised Lift
Specification for Rotary Evaporator, 1 L Flask, Motorised Lift Evaporation capacity (water) Max. 25 mL/min Rotation speed 20 to 300 rpm Evaporating flask 1 L, 131 mm diameter, 29 joint Collection bottle 1 L, 131 mm diameter, 35 joint Condenser Vertical, adjustable double-layer, anti-backflow design; 80 x 420 mm Condensation area 0.15 m² Bath temperature control range RT +5 °C to 180 °C Bath control accuracy ±1 °C Heating power 1.5 kW Enclosed heating size 230 x 135 mm Materials Stainless steel bath liner, aluminium alloy bracket Lifting Automatic lift, 120 mm stroke 11 further specifications on the full record.
Typical applications
- Solvent removal and recovery
- Concentration of extracts
- Sample preparation before chromatography
- Pilot work in pharmaceutical and chemical laboratories
- Food and botanical extract concentration
Also known as
- Rotavap
- Rotary vacuum evaporator
- Rotary film evaporator
- Solvent evaporator
Full record, hazard data and enquiry for Rotary Evaporator, 1 L Flask, Motorised Lift →
Paddle Blender Homogeniser, 400 mL, Heated
Paddle blender that works the sample inside a closed sterile bag, so the initial suspension is prepared without any part of the machine touching the sample.
IndentISO 6887-1Working capacity: 4 mL to 400 mL
Specification for Paddle Blender Homogeniser, 400 mL, Heated
Specification for Paddle Blender Homogeniser, 400 mL, Heated Working capacity 4 mL to 400 mL Slapping speed 3.0 to 12.0 squeezes per second Adjustable flapping distance 0 to 50 mm Paddle size 145 x 85 mm Paddle and front door material Stainless steel 304 Heating RT +5 °C to 80 °C Disinfection wavelength 253.7 nm ultraviolet Stored programmes 8 sets, speed and time adjustable Timing, alarm and pause Yes Automatic stop Yes Display 4.3 inch touch screen Sterile homogenising bag size 170 x 300 mm 7 further specifications on the full record.
Standards
ISO 6887-1Typical applications
- Preparation of initial suspensions for microbiological examination
- Food and dairy testing
- Environmental sample preparation
- Pharmaceutical microbiology
- Life-science research sample preparation
Also known as
- Bag mixer
- Laboratory blender
- Sterile bag homogeniser
- Paddle blender
- Microbiological sample blender
Full record, hazard data and enquiry for Paddle Blender Homogeniser, 400 mL, Heated →
Hand-Held Rotor-Stator Homogeniser, 10 to 250 mL
Hand-held rotor-stator disperser that shears a 10 to 250 mL sample in the gap between a spinning rotor and a fixed stator, for homogenising, emulsifying and cell disruption.
IndentWorking capacity: 10 to 250 mL
Specification for Hand-Held Rotor-Stator Homogeniser, 10 to 250 mL
Specification for Hand-Held Rotor-Stator Homogeniser, 10 to 250 mL Working capacity 10 to 250 mL Minimum processing capacity 10 mL Standard dispersing head 10 mm, stainless steel, removable for cleaning Speed 5,000 to 30,000 rpm Speed mode 6 gears, stepless regulation Maximum viscosity 5000 mPa·s (printed as 5000MPAS) Noise < 50 dB Protection class IP30 Power 160 W Power supply AC 220 V, 50 to 60 Hz Stand H-type stand supplied for hanging the drive Packing dimensions (L x W x H) 480 x 280 x 110 mm 4 further specifications on the full record.
Typical applications
- Tissue and cell disruption
- Emulsion and suspension preparation
- Bio-pharmaceutical and gene research sample preparation
- Cosmetics, inks and paints
- Nanomaterial dispersion
Also known as
- Rotor-stator homogeniser
- Handheld homogeniser
- Disperser
- Immersion homogeniser
- Tissue disperser
Full record, hazard data and enquiry for Hand-Held Rotor-Stator Homogeniser, 10 to 250 mL →
Tissue Grinder Homogeniser (Bead Beater), 12 x 5 mL or 24 x 2 mL
Bead-beating tissue grinder that shakes closed tubes loaded with grinding balls to break plant, animal and microbial material into a uniform lysate for nucleic acid and protein work.
IndentTube holder, TGH12 / TGH24: 5 mL x 12 tubes / 2 mL x 24 tubes
Specification for Tissue Grinder Homogeniser (Bead Beater), 12 x 5 mL or 24 x 2 mL
Specification for Tissue Grinder Homogeniser (Bead Beater), 12 x 5 mL or 24 x 2 mL Tube holder, TGH12 / TGH24 5 mL x 12 tubes / 2 mL x 24 tubes Tube holders illustrated 5 mL x 12, 2 mL x 24 and 2 mL x 48; only the 12 and 24 holders are named in the specification table Maximum speed 2500 rpm Frequency setting 30 to 70 Hz Sample crushing vibration 600 to 2100 times/min Fixture stroke 32 mm, vertical Rated power 375 W Frequency tracking Automatic Display Touch screen Time setting and pause setting Yes Lock Outside lock, yes Alarm and storage Automatic fault alarm; automatic programme storage 6 further specifications on the full record.
Typical applications
- Sample preparation for DNA and RNA extraction
- Protein extraction
- Plant and animal tissue grinding
- Bacteria and yeast disruption
- Dry grinding, wet grinding and mixing
Also known as
- Bead beater
- Bead mill homogeniser
- Tissue lyser
- Sample grinder
- Tissue homogeniser
Multi-Tube Vortex Mixer, 50 Tubes
Orbital vortex mixer that clamps a foam rack of tubes between two plates and mixes a whole batch at once, for extraction, resuspension and high-throughput mixing.
IndentMaximum tubes: 50, rack dependent
Specification for Multi-Tube Vortex Mixer, 50 Tubes
Specification for Multi-Tube Vortex Mixer, 50 Tubes Maximum tubes 50, rack dependent Speed range 500 to 3000 rpm Speed adjustment increment 1 rpm Shaking movement Horizontal orbital Amplitude 4 mm Operation modes 2 — impulse and continuous Maximum load capacity 4 kg Display LED, shows speed and time Timer Yes; 1 s display resolution, 1 min adjustment increment Motor Brushless Sponge test tube racks 5 types — 6 mm x 50 holes, 8 mm x 50 holes, 15 mm x 50 holes, 25 mm x 15 holes, 29 mm x 15 holes Power 60 W 7 further specifications on the full record.
Typical applications
- Batch mixing of tubes
- Resuspension of pellets
- Liquid-liquid extraction
- Sample preparation before analysis
- High-throughput laboratory mixing
Also known as
- Multi-tube vortexer
- Multi-vortex mixer
- Batch vortex mixer
- Rack vortex mixer
Full record, hazard data and enquiry for Multi-Tube Vortex Mixer, 50 Tubes →
Vortex Mixer, Digital, 100 to 2800 rpm
Single-tube orbital vortex mixer with digital speed and timer display, for resuspending pellets, mixing reagents and dissolving small samples one tube at a time.
IndentSpeed: 100 to 2800 rpm, adjustable
Specification for Vortex Mixer, Digital, 100 to 2800 rpm
Specification for Vortex Mixer, Digital, 100 to 2800 rpm Speed 100 to 2800 rpm, adjustable Shaking movement Orbital; circumference oscillation Orbital diameter 4 mm Operation modes 2 — auto run on the touch sensor, and continuous run Timer 1 s to 99 h 59 min 59 s Display LCD with white backlight; shows speed and time Adjustment method Keypad Motor Brushless Head Standard head supplied Base material Aluminium alloy, with soft silicone foot pads Ambient temperature 5 °C to 35 °C Humidity ≤ 80 % 6 further specifications on the full record.
Typical applications
- Resuspending pellets
- Mixing reagents in tubes
- Dissolving solids in small volumes
- Biochemistry and genetic engineering sample preparation
Also known as
- Vortex shaker
- Test tube shaker
- Cyclomixer
- Digital vortex mixer
Full record, hazard data and enquiry for Vortex Mixer, Digital, 100 to 2800 rpm →
Dry Bath Nitrogen Evaporator (Sample Concentrator), 12 or 24 Positions
Heated aluminium block that plays nitrogen onto the surface of 12 or 24 warmed tubes to concentrate solvent extracts down without oxidising heat-sensitive analytes.
IndentPositions, DBNE12 / DBNE24: 12 x 16.5 mm holes / 24 x 16.5 mm holes
Specification for Dry Bath Nitrogen Evaporator (Sample Concentrator), 12 or 24 Positions
Specification for Dry Bath Nitrogen Evaporator (Sample Concentrator), 12 or 24 Positions Positions, DBNE12 / DBNE24 12 x 16.5 mm holes / 24 x 16.5 mm holes Heating power, DBNE12 / DBNE24 400 W / 600 W Maximum gas pressure, DBNE12 / DBNE24 0.04 MPa / 0.12 MPa Temperature range RT +5 °C to 150 °C Temperature control accuracy ≤ ±0.5 °C Display resolution 0.1 °C Temperature rise time, 40 to 150 °C ≤ 30 min Programming Single and multi-point; 5 points supported Control Microcomputer processing unit, PID control Display LCD Maximum lifting stroke 285 mm Gas flow rate < 15 L/min 10 further specifications on the full record.
Typical applications
- Concentration of solvent extracts before chromatography
- Pesticide residue sample preparation
- Pharmaceutical and biotechnology sample concentration
- Environmental analysis
- Clinical and forensic sample preparation
Also known as
- Sample concentrator
- Nitrogen blowdown unit
- Nitrogen evaporator
- Dry bath concentrator
- Solvent evaporator, nitrogen
Microwave Digestion System, 6 or 12 Vessels, 15 MPa
Closed-vessel microwave digestion system that dissolves solid samples in acid at up to 400 °C and 15 MPa, ready for elemental determination by AAS, ICP-OES or ICP-MS.
IndentVessel quantity, LMDS600 / LMDS1200: 6 / 12
Specification for Microwave Digestion System, 6 or 12 Vessels, 15 MPa
Specification for Microwave Digestion System, 6 or 12 Vessels, 15 MPa Vessel quantity, LMDS600 / LMDS1200 6 / 12 Vessel volume 100 mL Vessel material TFM, modified PTFE Protection vessel material PEEK and glass fibre Pressure controlling range 0 to 15 MPa Pressure accuracy ±0.01 MPa Pressure monitoring Contactless sensor, each vessel monitored and controlled; no burst disc Temperature controlling range 50 °C to 400 °C Temperature accuracy ±0.1 °C Temperature monitoring Contactless infrared sensor, each vessel monitored and controlled Microwave power 0 to 1000 W, adjustable Microwave leakage < 5 mW/cm² 13 further specifications on the full record.
Typical applications
- Sample digestion for elemental analysis
- Pharmaceutical elemental impurities work
- Environmental, soil and water samples
- Geological and mining samples
- Petrochemical samples
- Food, feed and forensic samples
Also known as
- Microwave digester
- Closed vessel acid digestion system
- Pressure digestion system
- Microwave sample preparation system
Full record, hazard data and enquiry for Microwave Digestion System, 6 or 12 Vessels, 15 MPa →
Probe Sonicator, 650 W, 0.5 to 500 mL
Ultrasonic probe processor that drives a titanium horn directly into the liquid to disrupt cells and disperse solids by cavitation, at up to 650 W on 0.5 to 500 mL.
IndentFrequency: 20 to 25 kHz, automatic tracking
Specification for Probe Sonicator, 650 W, 0.5 to 500 mL
Specification for Probe Sonicator, 650 W, 0.5 to 500 mL Frequency 20 to 25 kHz, automatic tracking Output power 6.5 to 650 W, adjustable Output amplitude 0 to 100 %, adjustable Process capacity 0.5 to 500 mL (approx.) Standard probe 6 mm (1/4 in), titanium alloy Optional probes 2, 3, 8, 10 and 12 mm Temperature range 0 to 99 °C Temperature control Temperature probe supplied; indicator and controller Display 4.3 inch TFT touch screen; temperature, power and time Timer Selectable Data memory 20 groups User password protection Available 8 further specifications on the full record.
Typical applications
- Cell and tissue disruption
- Emulsification and dispersion
- Nanoparticle dispersion
- Extraction from solids
- Degassing and defoaming
- Accelerating chemical reactions
Also known as
- Ultrasonic homogeniser
- Ultrasonic cell disruptor
- Ultrasonic liquid processor
- Cell crusher
- Ultrasonic pulveriser
Full record, hazard data and enquiry for Probe Sonicator, 650 W, 0.5 to 500 mL →
Probe Sonicator with Acoustic Enclosure, 650 to 1800 W
Four-model range of ultrasonic probe processors supplied with a lit, UV-equipped acoustic enclosure and a circulating beaker, covering working volumes from 0.2 mL to 1500 mL.
IndentModels: PRO656, PRO900, PRO1200, PRO1800
Specification for Probe Sonicator with Acoustic Enclosure, 650 to 1800 W
Specification for Probe Sonicator with Acoustic Enclosure, 650 to 1800 W Models PRO656, PRO900, PRO1200, PRO1800 Frequency, PRO656 / PRO900 20 to 25 kHz Frequency, PRO1200 / PRO1800 19.5 to 20.5 kHz Power (adjustable), by model PRO656 6.5 to 650 W, PRO900 9 to 900 W, PRO1200 12 to 1200 W, PRO1800 18 to 1800 W Crushing capacity, by model PRO656 0.2 to 500 mL, PRO900 0.5 to 700 mL, PRO1200 3 to 1000 mL, PRO1800 10 to 1500 mL Standard probe, by model PRO656 6 mm, PRO900 10 mm, PRO1200 20 mm, PRO1800 22 mm Optional probes, by model PRO656 2/3/6/8/10/12 mm, PRO900 6/8/10/12/15 mm, PRO1200 10/15/20/22 mm, PRO1800 6/8/10/15/20/25 mm Volume by probe diameter, PRO656 2 mm 0.1-5 mL, 3 mm 3-10 mL, 6 mm 10-100 mL, 8 mm 20-200 mL, 10 mm 30-300 mL, 12 mm 50-500 mL Volume by probe diameter, PRO900 As PRO656 from 2 to 12 mm, plus 15 mm 100-700 mL Volume by probe diameter, PRO1200 3 mm 3-10 mL, 6 mm 10-100 mL, 8 mm 20-200 mL, 10 mm 30-300 mL, 15 mm 100-500 mL, 20 mm 100-1000 mL, 22 mm 200-1000 mL Volume by probe diameter, PRO1800 6 mm 10-100 mL, 8 mm 20-200 mL, 10 mm 30-300 mL, 15 mm 100-500 mL, 20 mm 100-1000 mL, 22 mm 200-1500 mL, 25 mm 500-1500 mL Usable amplitude band by probe Each probe has its own power ratio range, from 1-35 % on the 2 mm probe to 20-95 % on the 25 mm probe 13 further specifications on the full record.
Typical applications
- Disruption of animal, plant and virus cells
- Emulsification and separation
- Homogenisation and extraction
- Nanoparticle dispersion
- Defoaming and cleaning
- Accelerating chemical reactions
Also known as
- Ultrasonic homogeniser
- Ultrasonic cell disruptor
- Ultrasonic liquid processor
- Sonicator with soundproof cabinet
- Ultrasonic pulveriser
Full record, hazard data and enquiry for Probe Sonicator with Acoustic Enclosure, 650 to 1800 W →
Probe Sonicator, 650 W, Acoustic Enclosure with Remote Sample Lift
Ultrasonic probe processor in a lit, UV-equipped acoustic enclosure whose sample stand is raised and lowered by remote control, so the cabinet stays shut while the probe depth is set.
IndentFrequency: 20 to 25 kHz, automatic tracking
Specification for Probe Sonicator, 650 W, Acoustic Enclosure with Remote Sample Lift
Specification for Probe Sonicator, 650 W, Acoustic Enclosure with Remote Sample Lift Frequency 20 to 25 kHz, automatic tracking Power 6.5 to 650 W, adjustable; output amplitude 0 to 100 % Crushing and mixing capacity 0.2 to 500 mL Standard probe 6 mm, for 10 to 100 mL samples Optional probes 2, 3, 6, 8, 10 and 12 mm Volume by probe diameter 2 mm 0.2-5 mL, 3 mm 3-10 mL, 6 mm 10-100 mL, 8 mm 20-200 mL, 10 mm 30-300 mL, 12 mm 50-500 mL Power ratio by probe diameter 2 mm 1-35 %, 3 mm 1-45 %, 6 mm 1-70 %, 8 mm 1-80 %, 10 mm 1-90 %, 12 mm 10-90 % Probe material Titanium alloy Temperature range Ambient to 100 °C Single ultrasound time 0.1 to 99.9 s Display 7 inch touch screen; temperature, power, time and graph Data storage 20 sets 13 further specifications on the full record.
Typical applications
- Cell and tissue disruption
- Emulsification and dispersion
- Extraction from solids
- Nanoparticle dispersion
- Sample preparation for infectious or aerosol-generating material
Also known as
- Ultrasonic homogeniser with remote
- Ultrasonic cell disruptor
- Ultrasonic liquid processor
- Sonicator with soundproof cabinet
Hotplate Magnetic Stirrer, 300 °C, 2 L
Programmable hotplate magnetic stirrer with a stainless steel top plate to 300 °C and a plug-in probe that holds the temperature of the liquid rather than the plate.
IndentMaximum stirring volume: 2000 mL
Specification for Hotplate Magnetic Stirrer, 300 °C, 2 L
Specification for Hotplate Magnetic Stirrer, 300 °C, 2 L Maximum stirring volume 2000 mL Speed Up to 1250 rpm, digital control with bar-graph indication Top plate size 135 x 135 mm Plate material Stainless steel Maximum plate surface temperature 300 °C Temperature accuracy ±1 °C below 100 °C; ±3 °C below 300 °C Temperature control Microprocessor CPU; external ATC probe measures and maintains the temperature of the liquid Programmable settings Objective temperature, hold temperature, stirring time and speed Timer 999 minutes Display LCD Power supply AC 220 V, 50/60 Hz Packing dimensions (L x W x H) 310 x 255 x 190 mm 4 further specifications on the full record.
Typical applications
- Heated stirring of solutions
- Dissolution and reagent preparation
- Open-vessel sample digestion
- Culture media preparation
Also known as
- Magnetic stirrer with hotplate
- Heating magnetic stirrer
- Hot plate stirrer
- Stirrer hotplate
Full record, hazard data and enquiry for Hotplate Magnetic Stirrer, 300 °C, 2 L →
Graphite Hotplate, 300 x 200 mm, 420 °C
Flat graphite-topped laboratory hotplate under PID control, for heating, drying, baking and open-vessel digestion where the plate has to stand up to acid fume.
IndentPlate material: Graphite
Specification for Graphite Hotplate, 300 x 200 mm, 420 °C
Specification for Graphite Hotplate, 300 x 200 mm, 420 °C Plate material Graphite Surface film thickness 12 mm Heating surface size 300 x 200 mm Maximum temperature 420 °C Temperature accuracy ±2 °C Temperature control PID Electric heating plate Yes Magnetic stirring Not fitted - this is a heating plate only Display LCD Construction Anti-corrosive materials with anti-corrosive spraying Power 1500 W Power supply AC 220V / 50Hz 4 further specifications on the full record.
Typical applications
- Open-vessel acid digestion
- Drying and baking of samples
- Evaporation of digests
- Holding samples at a constant temperature
- General laboratory heating
Also known as
- Graphite hot plate
- Digestion hotplate
- Acid digestion hot plate
- Corrosion resistant hotplate
- Laboratory heating plate
Full record, hazard data and enquiry for Graphite Hotplate, 300 x 200 mm, 420 °C →
Oil Bath Magnetic Stirrer, 5 L
Heated 5 L oil bath with a magnetic stirrer drive beneath the pot, for holding a flask at a set temperature up to 300 °C while its contents are stirred.
IndentMaximum volume: 5000 ml
Specification for Oil Bath Magnetic Stirrer, 5 L
Specification for Oil Bath Magnetic Stirrer, 5 L Maximum volume 5000 ml Maximum temperature 300 °C Temperature resolution ±1 °C Temperature sensor and control PT100, PID Heating method Electric, tube heating element Liner material SS304 Liner height 145 mm Speed range Up to 2800 RPM (adjustable, stepless) Stirring power 12 W Time setting Yes Display LED Power wattage 1000 W 4 further specifications on the full record.
Typical applications
- Reflux and synthesis above 100 °C
- Constant-temperature reaction work
- Sample digestion in a bath
- Viscous-melt holding at temperature
Also known as
- Oil bath stirrer
- Heating mantle alternative
- Silicone oil bath with stirrer
- Magnetic stirrer with oil bath
- Reaction bath stirrer
Full record, hazard data and enquiry for Oil Bath Magnetic Stirrer, 5 L →
Overhead Stirrer, 20 L, 10000 mPa·s
Motor-driven overhead stirrer on a stand, for batches up to 20 L and for liquids too viscous for a magnetic follower to keep turning.
IndentMaximum volume: 20 L
Specification for Overhead Stirrer, 20 L, 10000 mPa·s
Specification for Overhead Stirrer, 20 L, 10000 mPa·s Maximum volume 20 L Maximum viscosity 10000 mPa·s Speed range 100 ~ 2500 RPM Speed setting mode Digital Stirring modes Clockwise, anticlockwise and alternating Working time Continuous Timer Yes Motor Digital brushless Motor power 60 W Stirring head Stainless steel Structure exterior Plastic shell Display LCD 6 further specifications on the full record.
Typical applications
- Mixing viscous solutions, gels and slurries
- Suspension and emulsion preparation
- Polymer and resin blending
- Large-batch dissolution up to 20 L
Also known as
- Overhead stirrer
- Mechanical stirrer
- Top-drive stirrer
- Laboratory paddle stirrer
- Digital overhead mixer
Full record, hazard data and enquiry for Overhead Stirrer, 20 L, 10000 mPa·s →
Ceramic-Coated Hotplate Magnetic Stirrer, 5 L, 150 x 150 mm Plate
Hotplate magnetic stirrer with a ceramic-coated cast aluminium top, for stirring and heating up to 5 L with a PT1000 probe reading the temperature in the liquid.
IndentMaximum stirring volume: 5000 ml
Specification for Ceramic-Coated Hotplate Magnetic Stirrer, 5 L, 150 x 150 mm Plate
Specification for Ceramic-Coated Hotplate Magnetic Stirrer, 5 L, 150 x 150 mm Plate Maximum stirring volume 5000 ml Top plate type Cast aluminium with ceramic coating Plate size 150 x 150 mm Maximum temperature 300 °C Temperature sensor PT1000 Speed range 100-1600 RPM (adjustable) Speed control accuracy ±10 RPM Rotation Forward and reverse Motor Brushless Stored programs Up to 6 groups of operating programs Time setting Yes Display LCD 6 further specifications on the full record.
Typical applications
- Dissolution and reagent preparation
- Heated stirring of buffers and media
- Small-scale synthesis
- Sample digestion in beakers
Also known as
- Ceramic hotplate magnetic stirrer
- Hot plate stirrer
- Magnetic stirrer with hotplate
- Heating magnetic stirrer
- Programmable hotplate stirrer
Ceramic-Coated Hotplate Magnetic Stirrer, 1 to 20 L, 170 x 170 mm Plate
Hotplate magnetic stirrer with a ceramic-coated cast aluminium top rated to 350 °C, for stirring and heating batches from 1 to 20 L with a PT1000 probe in the liquid.
IndentStirring volume (H₂O): 5 L standard (1 L - 20 L)
Specification for Ceramic-Coated Hotplate Magnetic Stirrer, 1 to 20 L, 170 x 170 mm Plate
Specification for Ceramic-Coated Hotplate Magnetic Stirrer, 1 to 20 L, 170 x 170 mm Plate Stirring volume (H₂O) 5 L standard (1 L - 20 L) Top plate type Cast aluminium with ceramic coating Plate size 170 x 170 mm Maximum temperature on plate 350 °C Temperature sensor PT1000 Speed range 100-2000 RPM (adjustable) Speed control accuracy ±10 RPM Rotation Forward and reverse Motor Brushless Parameter memory Automatically memorises the set working parameters Time setting Yes Display LCD 7 further specifications on the full record.
Typical applications
- Bulk buffer and media preparation
- Heated dissolution of large batches
- Reagent make-up in carboys and beakers
- Constant-temperature stirring
Also known as
- Ceramic hotplate magnetic stirrer 20 L
- Large volume magnetic stirrer
- Hot plate stirrer
- Heating magnetic stirrer
- High capacity stirrer hotplate
Multiposition Magnetic Stirrer, Four Places, Stirring or Stirring with Heating
Four-place magnetic stirrer for running several small batches side by side, supplied either as a stirring-only model or as a heated model that also holds the samples to 120 °C.
IndentModels covered: MMS15S (stirring) / MMS12H (stirring and heating)
Specification for Multiposition Magnetic Stirrer, Four Places, Stirring or Stirring with Heating
Specification for Multiposition Magnetic Stirrer, Four Places, Stirring or Stirring with Heating Models covered MMS15S (stirring) / MMS12H (stirring and heating) Number of stirring points 4 Maximum stirring volume 4 x 500 ml Plate size 100 x 110 mm (each) Speed, MMS15S / MMS12H 50 - 1500 RPM / 50 - 1200 RPM Plate material, MMS15S / MMS12H PET anti-corrosion plate / 304 stainless steel plate Temperature range, MMS15S / MMS12H NA, no heating / RT+5 °C to 120 °C Control Asynchronous control, each position set independently (synchronisation can be set) Mixing direction Clockwise PTFE paddle size 30 mm Display LCD Time setting Yes, with locking function 7 further specifications on the full record.
Typical applications
- Running four dissolutions or extractions in parallel
- Stability and comparison studies
- Reagent preparation in batches
- Teaching laboratories
Also known as
- Multiposition magnetic stirrer
- Multi-place stirrer
- 4 position magnetic stirrer
- Multi-point stirrer hotplate
- Parallel stirring station
Water Bath Magnetic Stirrer, 3 L
Stainless steel water bath with a magnetic stirrer under the tank, for holding a flask or beaker at a set temperature up to 100 °C while its contents are stirred.
IndentMaximum mixing volume: 3 L (2 L flask or 3 L beaker)
Specification for Water Bath Magnetic Stirrer, 3 L
Specification for Water Bath Magnetic Stirrer, 3 L Maximum mixing volume 3 L (2 L flask or 3 L beaker) Tank size (L x W x depth) 200 x 200 x 130 mm Tank Stainless steel inner tank with built-in heating tube Temperature range RT +5 °C ~ 100 °C Temperature resolution and stability 0.1 °C and ±1 °C Temperature control PID Dry-run protection Anti dry burning function Speed 100 RPM ~ 1200 RPM Speed increment 50 RPM Motor Brushless Control mode Digital control panel keys Time setting Yes 8 further specifications on the full record.
Typical applications
- Heated stirring of aqueous samples
- Dissolution and extraction below 100 °C
- Enzyme and buffer incubation with mixing
- Sample warming before analysis
Also known as
- Water bath stirrer
- Heated bath magnetic stirrer
- Waterbath magnetic stirrer
- Constant temperature bath with stirrer
Full record, hazard data and enquiry for Water Bath Magnetic Stirrer, 3 L →
Tube Roller Mixer, Six Rollers
Six-roller mixer that turns closed tubes slowly and continuously to keep blood, cell suspensions and other settling samples homogeneous without foaming them.
IndentType: Rotating shaking
Specification for Tube Roller Mixer, Six Rollers
Specification for Tube Roller Mixer, Six Rollers Type Rotating shaking Number of rollers 6 Roller size φ6-34 mm Roller length 280 mm Roller material Silicone Maximum capacity 10 x 50 ml centrifuge tube / 0.5 kg Speed 20-80 RPM Control mode Digital key Display LCD Time setting Yes Motor Brushless Design Anti-lock design 7 further specifications on the full record.
Typical applications
- Keeping blood samples mixed before analysis
- Gentle resuspension of cell cultures
- Hybridisation and immunoassay incubation in tubes
- Mixing viscous samples without aeration
Also known as
- Roller mixer
- Tube roller
- Blood tube rotator
- Rotating tube mixer
- Laboratory roller shaker
Full record, hazard data and enquiry for Tube Roller Mixer, Six Rollers →
Ultrasonic Cleaner, 2 L, Heated, with Degas
Bench ultrasonic bath with a 2 L stainless tank, 40 kHz transducers, a heater and a degas setting, for cleaning small parts and de-aerating small volumes of solvent.
IndentTank capacity: 2.0 L
Specification for Ultrasonic Cleaner, 2 L, Heated, with Degas
Specification for Ultrasonic Cleaner, 2 L, Heated, with Degas Tank capacity 2.0 L Tank material Stainless steel SS304 Tank size (LxWxH) 245 x 155 x 80 mm Overall size (LxWxH) 305 x 235 x 215 mm Ultrasonic frequency 40 kHz Ultrasonic power 65 W Heating power 100 W Heating temperature RT+5 °C ~ 60 °C Degas function Yes Timer 5 cycles: 90 s - 180 s - 280 s - 380 s - 480 s Display Digital control with LED display Protection Overheating protection; built-in cooling fan 6 further specifications on the full record.
Typical applications
- Cleaning glassware, cuvettes and small parts
- Degassing small solvent volumes
- Dissolving and dispersing samples before analysis
- Cleaning HPLC fittings and frits
Also known as
- Ultrasonic bath
- Ultrasonic cleaner 2 litre
- Sonication bath
- Digital ultrasonic cleaner
- Degassing bath
Full record, hazard data and enquiry for Ultrasonic Cleaner, 2 L, Heated, with Degas →
Digital Ultrasonic Cleaner with Degas, 2.5 L to 24 L
Digital ultrasonic bath in five tank sizes from 2.5 to 24 L, with heating, a 1 to 99 minute timer and a degas mode for de-aerating HPLC mobile phase and other solutions.
IndentModels covered: LMUC3D / LMUC6D / LMUC9D / LMUC12D / LMUC25D
Specification for Digital Ultrasonic Cleaner with Degas, 2.5 L to 24 L
Specification for Digital Ultrasonic Cleaner with Degas, 2.5 L to 24 L Models covered LMUC3D / LMUC6D / LMUC9D / LMUC12D / LMUC25D Tank capacity (approx.), 3D / 6D / 9D / 12D / 25D 2.5 L / 5 L / 8 L / 11 L / 24 L Tank size (mm), 3D / 6D / 9D / 12D / 25D 240x140x100 / 300x155x150 / 300x240x150 / 330x300x150 / 500x300x200 Overall size (mm), 3D / 6D / 9D / 12D / 25D 270x170x240 / 330x180x310 / 330x270x310 / 360x330x310 / 550x330x360 Ultrasonic power, 3D / 6D / 9D / 12D / 25D 100 W / 150 W / 200 W / 300 W / 500 W Heating power, 3D / 6D / 9D / 12D / 25D 100 W / 300 W / 300 W / 400 W / 500 W Ultrasonic frequency 40 kHz Power control Normal and soft power settings Degas function Yes Memory function Yes, retains the test setting Time setting 1-99 min, adjustable Heating temperature RT+5 °C ~ to 80 °C 9 further specifications on the full record.
Typical applications
- Degassing HPLC mobile phase and dissolution media
- Cleaning glassware, filters and instrument parts
- Dispersing and dissolving samples before analysis
- Cleaning surgical and dental instruments
Also known as
- Degassing ultrasonic bath
- Digital ultrasonic cleaner
- HPLC mobile phase degasser bath
- Ultrasonic cleaning bath SS304
- Sonication bath with heater
Full record, hazard data and enquiry for Digital Ultrasonic Cleaner with Degas, 2.5 L to 24 L →
Industrial Ultrasonic Cleaner, 12 L and 35 L, Knob Control
Knob-controlled stainless ultrasonic bath in 12 L and 35 L tank sizes with adjustable ultrasonic power, a heater and a drain valve, for bulk cleaning of laboratory and workshop hardware.
IndentModels covered: LMUC13M / LMUC35M
Specification for Industrial Ultrasonic Cleaner, 12 L and 35 L, Knob Control
Specification for Industrial Ultrasonic Cleaner, 12 L and 35 L, Knob Control Models covered LMUC13M / LMUC35M Tank capacity (approx.) 12 L / 35 L Tank size (LxWxH) 300 x 240 x 180 mm / 500 x 295 x 250 mm Overall size (LxWxH) 325 x 265 x 360 mm / 570 x 360 x 450 mm Ultrasonic power 300 W / 600 W Ultrasonic power adjustment 0 to 100%, adjustable Heating power 500 W / 800 W Heating temperature RT+7 ~ to 80 °C Ultrasonic frequency 40 kHz Time setting 0 to 30 min Control Knob type, with timer and heater setting Tank drain Drain valve 7 further specifications on the full record.
Typical applications
- Bulk cleaning of glassware and instrument parts
- Degreasing machined and workshop components
- Cleaning surgical and dental instruments
- Cleaning filters, nozzles and injectors
Also known as
- Industrial ultrasonic cleaner
- Large ultrasonic bath
- 35 litre ultrasonic cleaner
- SS304 ultrasonic cleaning tank
What laboratories usually order alongside this.
Ovens, Furnaces & Incubators
Hot air ovens, muffle and high-temperature furnaces, water baths, stability chambers and refrigerated equipment.
Analytical Instruments
Balances, pH and conductivity meters, spectrophotometers, titration apparatus, extraction and digestion systems.
Microbiology & Sterilisation
Autoclaves, laminar air flow cabinets, BOD and bacteriological incubators, colony counters and aseptic handling equipment.
Why we publish the standard revision, not just the number.
Testing instruments are bought against a method, and a method is written against a standard. When that standard is revised, the old number stays in circulation for years — sometimes decades — because catalogues copy each other and nobody re-checks.
Three examples currently live across this industry: ASTM D1559 for Marshall stability, withdrawn in 1998. ASTM D422 for hydrometer analysis, withdrawn in 2016. IS 13311 for non-destructive concrete testing, absorbed into the IS 516 family in 2018. All three still appear on product listings you can buy from today.
That matters commercially, not just pedantically. If your quality manual cites a withdrawn standard, a NABL assessor will raise it, and the fastest way that error enters a manual is by being copied off a supplier’s specification sheet.
On qualification: for pharmaceutical customers, the documentation is half the purchase. GMP-specification equipment differs in its contact surfaces, its control system, its printed cycle records and its IQ/OQ/PQ protocol set. Specify that requirement at enquiry stage — retrofitting it after installation costs more and delays qualification.
On site preparation: compression testing machines, ductility baths, abrasion machines and large ovens need foundations, three-phase supply, drainage or extraction. We issue the foundation drawing and utility schedule with the quotation so the civil work can run in parallel with the delivery lead time rather than after it.