Indent

Double-Beam UV-Visible Spectrophotometer, Dual Detector

Stand-alone double-beam UV-visible spectrophotometer whose two detectors read sample and reference at the same instant, offered with fixed or selectable bandwidth and a single or eight-position cell holder.

Typical applications

  • Pharmaceutical assay and identification
  • Wavelength scanning
  • Kinetics and time-course measurement
  • DNA and protein quantification
  • Multi-wavelength analysis
  • Water and effluent colorimetry

Conforms to

USP <857>
  • USP <857>Ultraviolet-Visible Spectroscopy

Add to enquiry

Enquire on WhatsApp

Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.

Worth knowing before you order

Read the bandwidth row twice before ordering. The table prints bandwidth in two places and they disagree: a per-model row gives 1 nm for the first two models and selectable 1.0 / 2.0 / 4.0 nm for the third and fourth, and a later row then gives 1 nm across all four. The per-model row is the one that distinguishes the models, so have the bandwidth confirmed in writing if you are buying for a method that names one. The other difference between the four is the cell holder: a single 10 mm position on the first and third models, an eight-position programmable changer on the second and fourth. The instrument runs stand-alone from its own LCD and does not need a PC. The Peltier / sipper system and the multi-cell holder are optional and quoted separately, and the multi-cell holder on this series takes cells up to 50 mm, not the 100 mm offered on the single-beam models. Baseline flatness and noise are both printed as ± 0.001 A/h, a drift unit that cannot be right for either, so both are left out.

Specification

Technical specification for Double-Beam UV-Visible Spectrophotometer, Dual Detector
Beam configurationDouble beam, 1200 lines/mm grating
DetectorSilicon photodiode; two detectors read sample and reference simultaneously
Wavelength range190–1100 nm
Spectral bandwidth, first and second models1 nm
Spectral bandwidth, third and fourth models1.0, 2.0, 4.0 nm, selectable
Sample cell holder, first and third models10 mm cell holder
Sample cell holder, second and fourth models8-cell programmable holder, 10 mm
Reference cell holder10 mm cell holder
Wavelength accuracy and repeatability± 0.3 nm; repeatability ± 0.2 nm
Photometric accuracy and repeatability± 0.3 %T; repeatability 0.2 %T
Photometric range−0.3 to 3 A; 0–200 %T; 0–9999 C
Stability± 0.001 A/h at 500 nm
Stray light≤ 0.05 %T at 220 nm and 360 nm
Light sourceDeuterium lamp and tungsten halogen lamp, individually selectable
Optical path length520 mm
Display6 in LCD, results and curves on the instrument
Data outputUSB port; parallel printer port
Power supplyAC 220 V, 50/60 Hz
Gross weight35 kg
Optional accessoriesPeltier / sipper system; multi-cell holder up to 50 mm

Support available

  • Installation & commissioning
  • Calibration
  • Validation & qualification (IQ/OQ/PQ)
  • Operator training
  • Annual maintenance contract
  • Spares & consumables

Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.