Touchscreen Single-Beam UV-Visible Spectrophotometer

Single-beam UV-visible spectrophotometer with a 7-inch touchscreen, 2 nm spectral bandwidth and on-board data handling, for fixed-wavelength assay and routine scanning.

Typical applications

  • Fixed-wavelength quantitative assay
  • Colorimetric determinations in water and effluent
  • Spectral scanning
  • DNA and protein quantification
  • Multi-wavelength analysis
  • Teaching and routine quality control

Conforms to

USP <857>
  • USP <857>Ultraviolet-Visible Spectroscopy

Add to enquiry

Enquire on WhatsApp

Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.

Worth knowing before you order

This is the single-beam instrument in the touchscreen family. A single beam reads the blank and the sample at different moments, so lamp drift lands in the result: re-blank often, and choose a double-beam model if you scan or run kinetics. Two figures also separate it from the double-beam version and are easy to miss — the bandwidth is fixed at 2.0 nm rather than 1.0 nm, and wavelength accuracy is ± 0.5 nm rather than ± 0.3 nm; if a method names a bandwidth, this instrument will not meet a 1 nm requirement. The feature list on the model's own page repeats the double-beam page's wording about a 'dual optical path and dual detector' and the table lists a reference cuvette position, but the optical system row says single beam — take the table row and have it confirmed in writing. The baseline flatness row is printed in A/h, a drift unit rather than a flatness unit, and a 'Focal Length 10 mm' row duplicates the cell path length; both are left out. The 21 CFR Part 11 wording in the catalogue describes the software, and Part 11 compliance is demonstrated by your validated process, not shipped with a machine.

Specification

Technical specification for Touchscreen Single-Beam UV-Visible Spectrophotometer
Beam configurationSingle beam
Wavelength range190–1100 nm
Spectral bandwidth2.0 nm, fixed
Resolution0.1 nm
Wavelength accuracy± 0.5 nm
Wavelength repeatability± 0.2 nm
Photometric range0–200 %T; −0.3 to 3.0 A; 0–9999 C
Photometric accuracy± 0.2 %T (0–100 %T); ± 0.002 Abs (0–0.5 Abs); ± 0.004 Abs (0.5–1.0 Abs)
Photometric repeatability≤ 0.1 %T (0–100 %T); 0.001 Abs (0–0.5 Abs); 0.002 Abs (0.5–1.0 Abs)
Stability± 0.001 A/h at 500 nm
Stray light0.05 %T at 220 nm and 360 nm
Cell holder10 mm each, sample and reference cuvette holder
Light sourceTungsten and deuterium lamps, with usage-hour monitoring
DetectorSilicon photodiode
Display and memory7 in touchscreen, 800 x 480 HD TFT; 32 GB built-in
Control modeStand-alone, or PC software
Data outputUSB
Power supplyAC 220 V, 50/60 Hz
Packing dimensions (L x W x H)645 x 550 x 405 mm
Gross weight25 kg

Support available

  • Installation & commissioning
  • Calibration
  • Validation & qualification (IQ/OQ/PQ)
  • Operator training
  • Annual maintenance contract
  • Spares & consumables

Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.