Indent

Touchscreen Double-Beam UV-Visible Spectrophotometer

Double-beam UV-visible spectrophotometer with a 10-inch touchscreen and on-board data handling, offered with fixed or selectable spectral bandwidth and with a single or eight-position cell holder.

Typical applications

  • Pharmaceutical assay and content uniformity
  • Spectral scanning
  • Kinetics and time-course measurement
  • DNA and protein quantification
  • Multi-wavelength analysis
  • Quantitative analysis against calibration curves

Conforms to

USP <857>
  • USP <857>Ultraviolet-Visible Spectroscopy

Add to enquiry

Enquire on WhatsApp

Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.

Worth knowing before you order

Four models share one page and only two things separate them. The first pair has a fixed 1.0 nm spectral bandwidth; the second pair adds selectable 1.0, 2.0, 4.0 and 5.0 nm — worth paying for only if a method you run names a bandwidth other than 1 nm. Independently of that, the second and fourth models carry an eight-position programmable cell changer instead of a single 10 mm holder. Do not read the 0.1 nm 'Resolution' row as the bandwidth: the bandwidth row is the one a pharmacopoeial method refers to. The baseline flatness row is printed in units of A/h, which is a drift unit rather than a flatness unit, and a 'Focal Length 10 mm' row duplicates the cell path length; both have been left out as unreadable. The catalogue says the PC software follows GLP and GMP 'mostly as per 21CFR Part 11' — Part 11 compliance is demonstrated by your own validated process and procedures, not shipped with an instrument, so specify what you need at enquiry stage. Direct A4 printing is offered through one named desktop inkjet printer, which is not part of the supply.

Specification

Technical specification for Touchscreen Double-Beam UV-Visible Spectrophotometer
Beam configurationDouble beam
Wavelength range190–1100 nm
Spectral bandwidth, first and second models1.0 nm
Spectral bandwidth, third and fourth models1.0, 2.0, 4.0, 5.0 nm, selectable
Sample cell holder, first and third models10 mm cell holder
Sample cell holder, second and fourth models8-cell programmable holder, 10 mm
Cell holder10 mm each, sample and reference cuvette holder
Wavelength accuracy and repeatability± 0.1 nm at the D2 656.1 nm line, ± 0.3 nm full range; repeatability ± 0.1 nm
Resolution0.1 nm
Photometric range0–200 %T; −0.3 to 3.0 A; 0–9999 C
Photometric accuracy± 0.2 %T (0–100 %T); ± 0.002 Abs (0–0.5 Abs); ± 0.004 Abs (0.5–1.0 Abs)
Stability± 0.0004 A/h at 500 nm
Stray light0.03 %T at 220 nm and 360 nm
Light sourceTungsten and deuterium lamps, with usage-hour monitoring
DetectorSilicon photodiode
Display and memory10 in touchscreen, 800 x 480 HD TFT; 32 GB built-in
Control mode and data outputStand-alone, or PC software; USB
Power supplyAdaptor, AC 220 V, 50/60 Hz
Dimensions and weight, first and second models785 x 585 x 400 mm; 35 kg
Dimensions and weight, third and fourth models790 x 600 x 400 mm; 36 kg

Support available

  • Installation & commissioning
  • Calibration
  • Validation & qualification (IQ/OQ/PQ)
  • Operator training
  • Annual maintenance contract
  • Spares & consumables

Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.