Indent

PMT Double-Beam UV-Visible Spectrophotometer with Mercury Lamp

Double-beam UV-visible spectrophotometer with a photomultiplier detector and a spectral bandwidth continuously adjustable from 0.1 to 5 nm, controlled from PC software.

Typical applications

  • Pharmaceutical assay and identification
  • Samples with sharp absorption peaks, such as the penicillins
  • Wavelength scanning
  • Kinetics and time-course measurement
  • Trace-level absorbance work

Conforms to

USP <857>
  • USP <857>Ultraviolet-Visible Spectroscopy

Add to enquiry

Enquire on WhatsApp

Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.

Worth knowing before you order

Three things decide this model against the fixed-bandwidth ones: the double-beam optics, the PMT detector, and the bandwidth being continuously adjustable from 0.1 to 5 nm rather than fixed at 1 or 2 nm — a pharmacopoeial method that names a bandwidth can be matched rather than argued about. There is no on-board display or keypad: the instrument is PC-software controlled and the catalogue states plainly that the computer is not supplied, so budget for one. Two printed figures have been left out because they cannot be right — the photometric range is printed as '0 – 10,00,000%T', which is not a possible transmittance, and base line flatness is printed as '±0.0005% Abs', mixing a percentage with an absorbance unit. The catalogue says the software 'mostly complies with GLP/GMP'; that is the manufacturer's claim about their software, not a product standard, and GLP or GMP status is demonstrated by your own validated process.

Specification

Technical specification for PMT Double-Beam UV-Visible Spectrophotometer with Mercury Lamp
Beam configurationDouble beam, Czerny-Turner optics
DetectorPhotomultiplier (PMT)
Wavelength range190–900 nm
Spectral bandwidth0.1–5 nm, continuously adjustable in 0.1 nm steps
Resolution0.1 nm
Wavelength accuracy± 0.3 nm
Photometric accuracy± 0.3%
Photometric range, absorbance and concentration−4 A to 6 A; 0 to 9999 C
Stray light≤ 0.005% at 220 nm and 360 nm
Stability≤ 0.0001 Abs/h
Light sourcesDeuterium, tungsten and mercury lamps
Mercury lamp functionReal-time wavelength calibration
Cell holder10 mm sample and reference cell holder
Scanning intervals8 settings: 0.025 / 0.05 / 0.1 / 0.2 / 0.5 / 1 / 2 / 5 nm
Control modePC software controlled
InterfaceUSB, RS232C, Ethernet
Power supplyAC 220 V, 50/60 Hz
Packing dimensions (L x W x H)710 x 690 x 540 mm
Gross weight49 kg

Support available

  • Installation & commissioning
  • Calibration
  • Validation & qualification (IQ/OQ/PQ)
  • Operator training
  • Annual maintenance contract
  • Spares & consumables

Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.