Micro Balance, 6.1 g x 0.001 mg, Touch Screen
Micro balance reading in 0.001 mg steps over a 6.1 g range, with motorised internal calibration and a double windshield, for weighing reference standards and sub-milligram samples.
Typical applications
- Weighing reference standards and impurity standards
- Sub-milligram sample preparation for trace analysis
- Filter and particulate gravimetry
- Calibration weight checking
- Research-scale synthesis
Add to enquiry
Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.
Worth knowing before you order
Read the repeatability and the linearity, not the readability. The display steps in 0.001 mg, but repeatability is quoted at 0.004 mg and linearity at ± 0.005 mg, so a single weighing is worth a few micrograms, not one, and the smallest sensible sample weight follows from those two figures rather than from the headline. Siting decides whether the balance ever reaches them: a micro balance stood on an ordinary bench near a door, a gangway, a fume cupboard or an air-conditioning outlet will not, whatever the specification says. It needs a heavy, level, isolated weighing bench and a room held between 18 and 24 °C, which is a narrower band than the 15-30 °C allowed for the analytical balances in this range. An anti-vibration pad and an external antistatic ioniser are supplied with the balance rather than quoted separately, which is worth knowing when comparing prices, but neither substitutes for the room. The pan is 30 mm across, so tall or wide vessels will not go in. The catalogue heads its pages 'an ISO 9001:2015 company'; that is a certificate held by the factory for its management system and says nothing about the weighing performance of this instrument.Specification
| Capacity × readability | 6.1 g × 0.001 mg |
|---|---|
| Readability (d) | 0.001 mg |
| Repeatability (standard deviation) | 0.004 mg |
| Linearity (±) | 0.005 mg |
| Calibration | Automatic internal (motorised) calibration |
| Display | 5" touch screen, seven-language interface |
| Response time | ≤ 8 s |
| Pan size | 30 mm |
| Weighing chamber size | 165 x 165 x 75 mm |
| Distance pan to top windshield | 75 mm |
| Windshield internal diameter | 165 mm |
| Windshield | Double windshield, metal-evaporated coating to reduce static charge |
| Tare range | Full |
| Operating temperature | 18 °C to 24 °C |
| Weighing units | g, mg, oz, ct, lb, ozt, dwt, GN, K1, K2, K3 |
| Embedded functions | Formulation, GLP, advanced piece counting, date and time, multi-user password protection |
| Interface | RS232C, USB |
| Baud rate options | 1200, 2400, 4800, 9600, 19200, 38400 |
| Indicator dimensions (L x W x H) | 173 x 180 x 92 mm |
| Power supply | Adaptor, AC 220 V / 50-60 Hz |
| Supplied as standard | Anti-vibration pad and external antistatic ioniser, weighing pan, ring, adaptor, manual, test certificate |
| Packing dimensions (L x W x H) | 555 x 385 x 470 mm |
| Gross weight | 11 kg |
Support available
- Installation & commissioning
- Calibration
- Validation & qualification (IQ/OQ/PQ)
- Operator training
- Annual maintenance contract
- Spares & consumables
Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.
Related products
Antistatic Ioniser for Balances, External and Windshield-Mounted
Bench ioniser that neutralises electrostatic charge on samples, containers and balance windshields, where static causes drifting and non-repeating readings on 0.01 and 0.1 mg balances.
IndentItem type: Accessory for micro, semi-micro and analytical balances; not a weighing instrument
Specification for Antistatic Ioniser for Balances, External and Windshield-Mounted
Specification for Antistatic Ioniser for Balances, External and Windshield-Mounted Item type Accessory for micro, semi-micro and analytical balances; not a weighing instrument Design type, two versions External free-standing device / unit attached to the balance windshield Balance compatibility, external version Any make of micro, semi-micro or analytical balance Balance compatibility, windshield version Listed for five specific balances in this range: the 220 g keypad analytical, the 82 g / 220 g and 102 g / 220 g semi-micro models, and the 220 g and 102 g / 220 g touch-screen models Operating modes 2-minute timed mode and continuous mode, started by a button Distance, sample to ion source Approx. 5-40 cm Discharge time 9 s at 5 cm, 13 s at 10 cm, 100 s at 40 cm (fan on) Ozone concentration 0-0.05 ppm at 2 cm from the ion source Ambient temperature 10 °C - 40 °C Air humidity 20-80% Power supply Adaptor, AC 100-240 V, 50/60 Hz Gross weight 300 g 1 further specification on the full record.
Typical applications
- Neutralising charge on plastic and glass weighing vessels
- Weighing dry powders that creep or scatter
- Weighing filters, films and plastic parts
- Semi-micro and micro weighing in dry air
- Handling toxic powders that must not disperse
Also known as
- Antistatic ionizer
- Static eliminator for balances
- Balance de-ioniser
- Static neutraliser
- Ionising blower for weighing
Semi-Micro / Analytical Balance, Touch Screen, 102 g / 220 g
Dual-range semi-micro and analytical balance reading to 0.01 mg on the 102 g range and 0.1 mg on the 220 g range, with internal calibration, a 5-inch touch screen and a GLP database.
IndentCapacity × readability: 102 g × 0.01 mg (semi-micro range); 220 g × 0.1 mg (analytical range)
Specification for Semi-Micro / Analytical Balance, Touch Screen, 102 g / 220 g
Specification for Semi-Micro / Analytical Balance, Touch Screen, 102 g / 220 g Capacity × readability 102 g × 0.01 mg (semi-micro range); 220 g × 0.1 mg (analytical range) Repeatability (standard deviation) 0.01 mg on the 102 g range; 0.1 mg on the 220 g range Linearity (±) 0.04 mg on the 102 g range; 0.4 mg on the 220 g range Sensitivity drift 3 ppm/°C Weighing cell Electromagnetic force compensation (EMFC) Calibration Internal calibration Display 5" touch screen Response time ≤ 6 s Pan size 80 mm Windshield dimensions 162 x 171 x 225 mm Operating temperature 15 °C - 25 °C Application modes Piece counting with statistics report, textile function, percentage, check weighing, animal weighing, formulation (recipe) 11 further specifications on the full record.
Typical applications
- Reference standard and impurity standard weighing
- Assay and content uniformity sample preparation
- Standard solution preparation
- Formulation and recipe weighing
- Density determination of solids and liquids
- Piece counting of small components
Also known as
- Semi-micro balance
- Touch screen analytical balance
- 0.01 mg balance
- Dual range analytical balance
- 102 g semi-micro balance
Semi-Micro / Analytical Balance, Touch Screen, 81 g / 220 g
Dual-range semi-micro and analytical balance reading to 0.01 mg on the 81 g range and 0.1 mg on the 220 g range, with internal calibration and an antistatic glass windshield.
IndentCapacity × readability: 81 g × 0.01 mg (semi-micro range); 220 g × 0.1 mg (analytical range)
Specification for Semi-Micro / Analytical Balance, Touch Screen, 81 g / 220 g
Specification for Semi-Micro / Analytical Balance, Touch Screen, 81 g / 220 g Capacity × readability 81 g × 0.01 mg (semi-micro range); 220 g × 0.1 mg (analytical range) Repeatability (standard deviation) 0.01 mg on the 81 g range; 0.1 mg on the 220 g range Linearity (±) 0.04 mg on the 81 g range; 0.4 mg on the 220 g range Sensitivity drift (±) 2 ppm/°C Verification scale interval (e) 1 mg Accuracy class as printed Class I Weighing cell Electromagnetic force compensation (EMFC) Calibration Internal calibration Display 4.3" touch screen, time on display, built-in temperature sensor Response time 4-6 s Pan size 90 mm Ø Windshield Glass, antistatic material 13 further specifications on the full record.
Typical applications
- Semi-micro sample and standard weighing
- Standard solution preparation
- Dynamic weighing of unstable loads
- Density determination of solids and liquids
- Piece counting
- Percentage and Σ weighing
Also known as
- Semi-micro balance
- Touch screen semi-micro balance
- 0.01 mg balance
- Dual range analytical balance
- 81 g semi-micro balance
Semi-Micro Balance, 61 g x 0.01 mg
Single-range semi-micro balance reading in 0.01 mg steps to 61 g, with internal calibration triggered by elapsed time and by temperature change, for laboratory and analytical weighing.
IndentCapacity × readability: 61 g × 0.01 mg
Specification for Semi-Micro Balance, 61 g x 0.01 mg
Specification for Semi-Micro Balance, 61 g x 0.01 mg Capacity × readability 61 g × 0.01 mg Linearity (±) 0.04 mg Sensitivity drift 2 ppm/°C Minimum weighing 1 mg Accuracy class as printed Class I Weighing cell Electromagnetic force sensor Calibration Internal calibration, triggered on elapsed time and on temperature change Display LCD, with time and temperature display Response time 4-6 s Pan size Φ 80 mm Tare range Full Ambient temperature 15 °C - 25 °C 9 further specifications on the full record.
Typical applications
- Semi-micro standard and sample weighing
- Standard solution preparation
- Reference material weighing
- Percentage and counting work
- Routine analytical laboratory weighing
Also known as
- Semi-micro balance
- 0.01 mg balance
- 61 g semi-micro balance
- Semi-micro analytical balance
- Ten microgram balance
Full record, hazard data and enquiry for Semi-Micro Balance, 61 g x 0.01 mg →