Semi-Micro / Analytical Balance, Touch Screen, 81 g / 220 g
Dual-range semi-micro and analytical balance reading to 0.01 mg on the 81 g range and 0.1 mg on the 220 g range, with internal calibration and an antistatic glass windshield.
Typical applications
- Semi-micro sample and standard weighing
- Standard solution preparation
- Dynamic weighing of unstable loads
- Density determination of solids and liquids
- Piece counting
- Percentage and Σ weighing
Add to enquiry
Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.
Worth knowing before you order
The fine range is 81 g, against 102 g on the otherwise similar touch-screen model in this range — the two look alike and are not the same buy if samples plus tare will pass 81 g on the 0.01 mg range. Note also what the numbers mean: 0.01 mg is the readability, repeatability is quoted at 0.01 mg and linearity at ± 0.04 mg, and it is those last two that decide whether the reading is worth anything. The 'verification scale interval (e) 1 mg' and 'Class I' rows are legal-metrology figures for trade verification, not the resolution of the display. A 0.01 mg balance is environment-limited: it wants a heavy, level bench away from doors, walkways and air outlets, and the anti-vibration pad supplied as standard will not compensate for a bad position. The glass windshield is described as antistatic material, which helps but does not remove charge from the sample itself — the ioniser listed elsewhere in this catalogue is the tool for that and is quoted separately, as is the density determination kit the density function needs. The catalogue claims GLP/GMP compliance and heads its pages 'an ISO 9001:2015 company': the first describes features such as calibration records and printouts, the second is the factory's management-system certificate; neither is a performance standard for this balance.Specification
| Capacity × readability | 81 g × 0.01 mg (semi-micro range); 220 g × 0.1 mg (analytical range) |
|---|---|
| Repeatability (standard deviation) | 0.01 mg on the 81 g range; 0.1 mg on the 220 g range |
| Linearity (±) | 0.04 mg on the 81 g range; 0.4 mg on the 220 g range |
| Sensitivity drift (±) | 2 ppm/°C |
| Verification scale interval (e) | 1 mg |
| Accuracy class as printed | Class I |
| Weighing cell | Electromagnetic force compensation (EMFC) |
| Calibration | Internal calibration |
| Display | 4.3" touch screen, time on display, built-in temperature sensor |
| Response time | 4-6 s |
| Pan size | 90 mm Ø |
| Windshield | Glass, antistatic material |
| Weighing chamber size | 162 x 180 x 210 mm |
| Tare range | Full |
| Operating temperature | 15 °C to 30 °C |
| Weighing units | g, mg, oz, ct |
| Application modes | Basic, dynamic, percentage, piece counting, density determination, Σ weighing |
| Data output mode | Command and continuous output |
| Interface | RS232C, USB |
| Baud rate options | 1200, 2400, 4800, 9600 |
| Power supply | DC 9 V adaptor, AC 220 V / 50-60 Hz |
| Supplied as standard | Anti-vibration pad, pan, power adaptor, manual, test certificate |
| Packing dimensions (L x W x H) | 420 x 315 x 445 mm |
| Gross weight | 9 kg |
Support available
- Installation & commissioning
- Calibration
- Validation & qualification (IQ/OQ/PQ)
- Operator training
- Annual maintenance contract
- Spares & consumables
Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.
Related products
Micro Balance, 6.1 g x 0.001 mg, Touch Screen
Micro balance reading in 0.001 mg steps over a 6.1 g range, with motorised internal calibration and a double windshield, for weighing reference standards and sub-milligram samples.
IndentCapacity × readability: 6.1 g × 0.001 mg
Specification for Micro Balance, 6.1 g x 0.001 mg, Touch Screen
Specification for Micro Balance, 6.1 g x 0.001 mg, Touch Screen Capacity × readability 6.1 g × 0.001 mg Readability (d) 0.001 mg Repeatability (standard deviation) 0.004 mg Linearity (±) 0.005 mg Calibration Automatic internal (motorised) calibration Display 5" touch screen, seven-language interface Response time ≤ 8 s Pan size 30 mm Weighing chamber size 165 x 165 x 75 mm Distance pan to top windshield 75 mm Windshield internal diameter 165 mm Windshield Double windshield, metal-evaporated coating to reduce static charge 12 further specifications on the full record.
Typical applications
- Weighing reference standards and impurity standards
- Sub-milligram sample preparation for trace analysis
- Filter and particulate gravimetry
- Calibration weight checking
- Research-scale synthesis
Also known as
- Microbalance
- 1 microgram balance
- 0.001 mg balance
- Micro analytical balance
- 6.1 g microbalance
Full record, hazard data and enquiry for Micro Balance, 6.1 g x 0.001 mg, Touch Screen →
Antistatic Ioniser for Balances, External and Windshield-Mounted
Bench ioniser that neutralises electrostatic charge on samples, containers and balance windshields, where static causes drifting and non-repeating readings on 0.01 and 0.1 mg balances.
IndentItem type: Accessory for micro, semi-micro and analytical balances; not a weighing instrument
Specification for Antistatic Ioniser for Balances, External and Windshield-Mounted
Specification for Antistatic Ioniser for Balances, External and Windshield-Mounted Item type Accessory for micro, semi-micro and analytical balances; not a weighing instrument Design type, two versions External free-standing device / unit attached to the balance windshield Balance compatibility, external version Any make of micro, semi-micro or analytical balance Balance compatibility, windshield version Listed for five specific balances in this range: the 220 g keypad analytical, the 82 g / 220 g and 102 g / 220 g semi-micro models, and the 220 g and 102 g / 220 g touch-screen models Operating modes 2-minute timed mode and continuous mode, started by a button Distance, sample to ion source Approx. 5-40 cm Discharge time 9 s at 5 cm, 13 s at 10 cm, 100 s at 40 cm (fan on) Ozone concentration 0-0.05 ppm at 2 cm from the ion source Ambient temperature 10 °C - 40 °C Air humidity 20-80% Power supply Adaptor, AC 100-240 V, 50/60 Hz Gross weight 300 g 1 further specification on the full record.
Typical applications
- Neutralising charge on plastic and glass weighing vessels
- Weighing dry powders that creep or scatter
- Weighing filters, films and plastic parts
- Semi-micro and micro weighing in dry air
- Handling toxic powders that must not disperse
Also known as
- Antistatic ionizer
- Static eliminator for balances
- Balance de-ioniser
- Static neutraliser
- Ionising blower for weighing
Semi-Micro / Analytical Balance, Touch Screen, 102 g / 220 g
Dual-range semi-micro and analytical balance reading to 0.01 mg on the 102 g range and 0.1 mg on the 220 g range, with internal calibration, a 5-inch touch screen and a GLP database.
IndentCapacity × readability: 102 g × 0.01 mg (semi-micro range); 220 g × 0.1 mg (analytical range)
Specification for Semi-Micro / Analytical Balance, Touch Screen, 102 g / 220 g
Specification for Semi-Micro / Analytical Balance, Touch Screen, 102 g / 220 g Capacity × readability 102 g × 0.01 mg (semi-micro range); 220 g × 0.1 mg (analytical range) Repeatability (standard deviation) 0.01 mg on the 102 g range; 0.1 mg on the 220 g range Linearity (±) 0.04 mg on the 102 g range; 0.4 mg on the 220 g range Sensitivity drift 3 ppm/°C Weighing cell Electromagnetic force compensation (EMFC) Calibration Internal calibration Display 5" touch screen Response time ≤ 6 s Pan size 80 mm Windshield dimensions 162 x 171 x 225 mm Operating temperature 15 °C - 25 °C Application modes Piece counting with statistics report, textile function, percentage, check weighing, animal weighing, formulation (recipe) 11 further specifications on the full record.
Typical applications
- Reference standard and impurity standard weighing
- Assay and content uniformity sample preparation
- Standard solution preparation
- Formulation and recipe weighing
- Density determination of solids and liquids
- Piece counting of small components
Also known as
- Semi-micro balance
- Touch screen analytical balance
- 0.01 mg balance
- Dual range analytical balance
- 102 g semi-micro balance
Semi-Micro Balance, 61 g x 0.01 mg
Single-range semi-micro balance reading in 0.01 mg steps to 61 g, with internal calibration triggered by elapsed time and by temperature change, for laboratory and analytical weighing.
IndentCapacity × readability: 61 g × 0.01 mg
Specification for Semi-Micro Balance, 61 g x 0.01 mg
Specification for Semi-Micro Balance, 61 g x 0.01 mg Capacity × readability 61 g × 0.01 mg Linearity (±) 0.04 mg Sensitivity drift 2 ppm/°C Minimum weighing 1 mg Accuracy class as printed Class I Weighing cell Electromagnetic force sensor Calibration Internal calibration, triggered on elapsed time and on temperature change Display LCD, with time and temperature display Response time 4-6 s Pan size Φ 80 mm Tare range Full Ambient temperature 15 °C - 25 °C 9 further specifications on the full record.
Typical applications
- Semi-micro standard and sample weighing
- Standard solution preparation
- Reference material weighing
- Percentage and counting work
- Routine analytical laboratory weighing
Also known as
- Semi-micro balance
- 0.01 mg balance
- 61 g semi-micro balance
- Semi-micro analytical balance
- Ten microgram balance
Full record, hazard data and enquiry for Semi-Micro Balance, 61 g x 0.01 mg →