Moisture Analyser, 110 g x 1 mg, Halogen or Infrared Heating
Loss-on-drying moisture analyser that weighs a sample, dries it in place under a halogen or infrared lamp and reports the mass lost as per cent moisture, with a touch screen and a live drying curve.
Typical applications
- Moisture in grain, flour and food powders
- Moisture in plastic granules and polymer feedstock
- Loss on drying of powders and granules
- Moisture in soil, sand and mineral samples
- Incoming-goods checks against a fixed in-house drying method
Add to enquiry
Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.
Worth knowing before you order
This is not a balance with a lamp on it. It weighs the sample, drives off the volatile fraction under the lamp and reports the mass lost, so the answer is a property of the method as much as of the sample: the drying temperature, the end-point rule (fixed time or auto-stop on rate of change) and the sample mass all move the number. A result is only comparable against a fixed, documented method, and only comparable with an oven figure once the two have been correlated on your own material. The two models differ in the lamp and in the ceiling temperature: the halogen version goes to 199 °C, the infrared version stops at 160 °C, so a method calling for drying above 160 °C rules the infrared model out. Readability and repeatability are both 1 mg, and that is what limits the result on a small sample - on a 2 g sample 1 mg is about 0.05 % moisture, so the 0.01 % display step is finer than the measurement behind it. Calibration is external and no calibration weight appears in the standard accessory list; the aluminium pans are consumables, 50 are supplied.Specification
| Heating source, halogen model / infrared model | Halogen lamp / infrared lamp |
|---|---|
| Temperature setting, halogen model / infrared model | 40 °C to 199 °C / 40 °C to 160 °C |
| Temperature step and sensor | 1 °C step, PT-100 sensor |
| Weighing capacity | 110 g |
| Readability | 0.001 g (1 mg) |
| Repeatability | 0.001 g |
| Linearity (±) | 0.003 g |
| Moisture / dry range and resolution | 100.00 % to 0.00 %, resolution 0.01 % |
| Drying curve | Yes, graph of residual moisture against time |
| Drying time setting | 1 to 99 minutes, with auto-stop mode |
| Stored settings | 20 |
| Display | Touch screen |
| Sample pan size | 90 mm Ø |
| Weighing sensor | Loadcell |
| Calibration | External |
| Operating temperature | 5 °C to 35 °C |
| Interface | RS232C |
| Power supply | AC 220 V / 50-60 Hz |
| Packing dimensions (L x W x H) | 485 x 340 x 355 mm |
| Gross weight | 7 kg |
| Supplied with | Aluminium pans (50 nos.), dust plate, pan handle, pan supporter, power cable, instruction manual, test certificate |
| HSN code | 90160010 |
Support available
- Installation & commissioning
- Calibration
- Validation & qualification (IQ/OQ/PQ)
- Operator training
- Annual maintenance contract
- Spares & consumables
Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.
Related products
Micro Balance, 6.1 g x 0.001 mg, Touch Screen
Micro balance reading in 0.001 mg steps over a 6.1 g range, with motorised internal calibration and a double windshield, for weighing reference standards and sub-milligram samples.
IndentCapacity × readability: 6.1 g × 0.001 mg
Specification for Micro Balance, 6.1 g x 0.001 mg, Touch Screen
Specification for Micro Balance, 6.1 g x 0.001 mg, Touch Screen Capacity × readability 6.1 g × 0.001 mg Readability (d) 0.001 mg Repeatability (standard deviation) 0.004 mg Linearity (±) 0.005 mg Calibration Automatic internal (motorised) calibration Display 5" touch screen, seven-language interface Response time ≤ 8 s Pan size 30 mm Weighing chamber size 165 x 165 x 75 mm Distance pan to top windshield 75 mm Windshield internal diameter 165 mm Windshield Double windshield, metal-evaporated coating to reduce static charge 12 further specifications on the full record.
Typical applications
- Weighing reference standards and impurity standards
- Sub-milligram sample preparation for trace analysis
- Filter and particulate gravimetry
- Calibration weight checking
- Research-scale synthesis
Also known as
- Microbalance
- 1 microgram balance
- 0.001 mg balance
- Micro analytical balance
- 6.1 g microbalance
Full record, hazard data and enquiry for Micro Balance, 6.1 g x 0.001 mg, Touch Screen →
Antistatic Ioniser for Balances, External and Windshield-Mounted
Bench ioniser that neutralises electrostatic charge on samples, containers and balance windshields, where static causes drifting and non-repeating readings on 0.01 and 0.1 mg balances.
IndentItem type: Accessory for micro, semi-micro and analytical balances; not a weighing instrument
Specification for Antistatic Ioniser for Balances, External and Windshield-Mounted
Specification for Antistatic Ioniser for Balances, External and Windshield-Mounted Item type Accessory for micro, semi-micro and analytical balances; not a weighing instrument Design type, two versions External free-standing device / unit attached to the balance windshield Balance compatibility, external version Any make of micro, semi-micro or analytical balance Balance compatibility, windshield version Listed for five specific balances in this range: the 220 g keypad analytical, the 82 g / 220 g and 102 g / 220 g semi-micro models, and the 220 g and 102 g / 220 g touch-screen models Operating modes 2-minute timed mode and continuous mode, started by a button Distance, sample to ion source Approx. 5-40 cm Discharge time 9 s at 5 cm, 13 s at 10 cm, 100 s at 40 cm (fan on) Ozone concentration 0-0.05 ppm at 2 cm from the ion source Ambient temperature 10 °C - 40 °C Air humidity 20-80% Power supply Adaptor, AC 100-240 V, 50/60 Hz Gross weight 300 g 1 further specification on the full record.
Typical applications
- Neutralising charge on plastic and glass weighing vessels
- Weighing dry powders that creep or scatter
- Weighing filters, films and plastic parts
- Semi-micro and micro weighing in dry air
- Handling toxic powders that must not disperse
Also known as
- Antistatic ionizer
- Static eliminator for balances
- Balance de-ioniser
- Static neutraliser
- Ionising blower for weighing
Semi-Micro / Analytical Balance, Touch Screen, 102 g / 220 g
Dual-range semi-micro and analytical balance reading to 0.01 mg on the 102 g range and 0.1 mg on the 220 g range, with internal calibration, a 5-inch touch screen and a GLP database.
IndentCapacity × readability: 102 g × 0.01 mg (semi-micro range); 220 g × 0.1 mg (analytical range)
Specification for Semi-Micro / Analytical Balance, Touch Screen, 102 g / 220 g
Specification for Semi-Micro / Analytical Balance, Touch Screen, 102 g / 220 g Capacity × readability 102 g × 0.01 mg (semi-micro range); 220 g × 0.1 mg (analytical range) Repeatability (standard deviation) 0.01 mg on the 102 g range; 0.1 mg on the 220 g range Linearity (±) 0.04 mg on the 102 g range; 0.4 mg on the 220 g range Sensitivity drift 3 ppm/°C Weighing cell Electromagnetic force compensation (EMFC) Calibration Internal calibration Display 5" touch screen Response time ≤ 6 s Pan size 80 mm Windshield dimensions 162 x 171 x 225 mm Operating temperature 15 °C - 25 °C Application modes Piece counting with statistics report, textile function, percentage, check weighing, animal weighing, formulation (recipe) 11 further specifications on the full record.
Typical applications
- Reference standard and impurity standard weighing
- Assay and content uniformity sample preparation
- Standard solution preparation
- Formulation and recipe weighing
- Density determination of solids and liquids
- Piece counting of small components
Also known as
- Semi-micro balance
- Touch screen analytical balance
- 0.01 mg balance
- Dual range analytical balance
- 102 g semi-micro balance
Semi-Micro / Analytical Balance, Touch Screen, 81 g / 220 g
Dual-range semi-micro and analytical balance reading to 0.01 mg on the 81 g range and 0.1 mg on the 220 g range, with internal calibration and an antistatic glass windshield.
IndentCapacity × readability: 81 g × 0.01 mg (semi-micro range); 220 g × 0.1 mg (analytical range)
Specification for Semi-Micro / Analytical Balance, Touch Screen, 81 g / 220 g
Specification for Semi-Micro / Analytical Balance, Touch Screen, 81 g / 220 g Capacity × readability 81 g × 0.01 mg (semi-micro range); 220 g × 0.1 mg (analytical range) Repeatability (standard deviation) 0.01 mg on the 81 g range; 0.1 mg on the 220 g range Linearity (±) 0.04 mg on the 81 g range; 0.4 mg on the 220 g range Sensitivity drift (±) 2 ppm/°C Verification scale interval (e) 1 mg Accuracy class as printed Class I Weighing cell Electromagnetic force compensation (EMFC) Calibration Internal calibration Display 4.3" touch screen, time on display, built-in temperature sensor Response time 4-6 s Pan size 90 mm Ø Windshield Glass, antistatic material 13 further specifications on the full record.
Typical applications
- Semi-micro sample and standard weighing
- Standard solution preparation
- Dynamic weighing of unstable loads
- Density determination of solids and liquids
- Piece counting
- Percentage and Σ weighing
Also known as
- Semi-micro balance
- Touch screen semi-micro balance
- 0.01 mg balance
- Dual range analytical balance