Semi-Micro / Analytical Balance, 102 g / 220 g, Graphic Display
Dual-range semi-micro and analytical balance reading to 0.01 mg on the 102 g range and 0.1 mg on the 220 g range, with internal calibration, a backlit graphic display and a 99-recipe database.
Typical applications
- Semi-micro standard and sample weighing
- Formulation and recipe weighing
- Standard solution preparation
- Check weighing against a threshold
- Density determination of solids and liquids
- Animal weighing and piece counting
Add to enquiry
Add as many products as you need and send one enquiry covering all of them, or send this item on its own. Bulk and drum quantities are quoted on request.
Worth knowing before you order
This is the keypad-and-graphic-display alternative to the touch-screen 102 g / 220 g model in the same range, and the weighing figures are the same on both: 0.01 mg readability with 0.01 mg repeatability and ± 0.04 mg linearity on the fine range. The difference that costs money later is the interface — this model lists RS232C only, with no USB, so exporting weights means a serial printer or a serial-to-USB converter and a PC that will talk to it. The recipe database (99 formulations, 20 ingredients each) is the reason to choose it for dispensing work. Internal calibration keeps it in tolerance as the room warms without anyone running a weight. As with any 0.01 mg balance the specification assumes a stable, level bench in a draught-free room: the anti-vibration pad is supplied as standard and deals with bench vibration only, not with a door, a gangway or an air-conditioning outlet. The density determination kit for liquid or solid samples is optional and quoted separately.Specification
| Capacity × readability | 102 g × 0.01 mg (semi-micro range); 220 g × 0.1 mg (analytical range) |
|---|---|
| Repeatability (standard deviation) | 0.01 mg on the 102 g range; 0.1 mg on the 220 g range |
| Linearity (±) | 0.04 mg on the 102 g range; 0.4 mg on the 220 g range |
| Accuracy class as printed | Class I |
| Calibration | Internal calibration, with GLP record of the last stored calibration |
| Display | Graphic display with backlight, date and time |
| Response time | 4-6 s |
| Pan size | 80 mm Ø |
| Weighing chamber size | 170 x 160 x 220 mm |
| Tare range | Full |
| Operating temperature | +15 °C to +30 °C |
| Weighing units | g, mg, oz, ct, lb, ozt, dwt, GN |
| Application modes | Piece counting, percentage, check weighing, animal weighing, threshold function, density, Σ weighing |
| Recipe database | 99 recipes, up to 20 ingredients each |
| Density function | Available; determination kit optional and quoted separately |
| Interface | RS232C |
| Baud rate options | 1200, 2400, 4800, 9600 |
| Power supply | DC 24 V, AC 220 V / 50-60 Hz |
| Supplied as standard | Anti-vibration pad, weighing pan, ring, power adaptor, manual, test certificate |
| Packing dimensions (L x W x H) | 515 x 400 x 525 mm |
| Gross weight | 8 kg |
Support available
- Installation & commissioning
- Calibration
- Validation & qualification (IQ/OQ/PQ)
- Operator training
- Annual maintenance contract
- Spares & consumables
Calibration is arranged through NABL-accredited laboratories under the relevant scope. We state the scope and the certificate number on the quotation — see what accreditation actually covers.
Related products
Micro Balance, 6.1 g x 0.001 mg, Touch Screen
Micro balance reading in 0.001 mg steps over a 6.1 g range, with motorised internal calibration and a double windshield, for weighing reference standards and sub-milligram samples.
IndentCapacity × readability: 6.1 g × 0.001 mg
Specification for Micro Balance, 6.1 g x 0.001 mg, Touch Screen
Specification for Micro Balance, 6.1 g x 0.001 mg, Touch Screen Capacity × readability 6.1 g × 0.001 mg Readability (d) 0.001 mg Repeatability (standard deviation) 0.004 mg Linearity (±) 0.005 mg Calibration Automatic internal (motorised) calibration Display 5" touch screen, seven-language interface Response time ≤ 8 s Pan size 30 mm Weighing chamber size 165 x 165 x 75 mm Distance pan to top windshield 75 mm Windshield internal diameter 165 mm Windshield Double windshield, metal-evaporated coating to reduce static charge 12 further specifications on the full record.
Typical applications
- Weighing reference standards and impurity standards
- Sub-milligram sample preparation for trace analysis
- Filter and particulate gravimetry
- Calibration weight checking
- Research-scale synthesis
Also known as
- Microbalance
- 1 microgram balance
- 0.001 mg balance
- Micro analytical balance
- 6.1 g microbalance
Full record, hazard data and enquiry for Micro Balance, 6.1 g x 0.001 mg, Touch Screen →
Antistatic Ioniser for Balances, External and Windshield-Mounted
Bench ioniser that neutralises electrostatic charge on samples, containers and balance windshields, where static causes drifting and non-repeating readings on 0.01 and 0.1 mg balances.
IndentItem type: Accessory for micro, semi-micro and analytical balances; not a weighing instrument
Specification for Antistatic Ioniser for Balances, External and Windshield-Mounted
Specification for Antistatic Ioniser for Balances, External and Windshield-Mounted Item type Accessory for micro, semi-micro and analytical balances; not a weighing instrument Design type, two versions External free-standing device / unit attached to the balance windshield Balance compatibility, external version Any make of micro, semi-micro or analytical balance Balance compatibility, windshield version Listed for five specific balances in this range: the 220 g keypad analytical, the 82 g / 220 g and 102 g / 220 g semi-micro models, and the 220 g and 102 g / 220 g touch-screen models Operating modes 2-minute timed mode and continuous mode, started by a button Distance, sample to ion source Approx. 5-40 cm Discharge time 9 s at 5 cm, 13 s at 10 cm, 100 s at 40 cm (fan on) Ozone concentration 0-0.05 ppm at 2 cm from the ion source Ambient temperature 10 °C - 40 °C Air humidity 20-80% Power supply Adaptor, AC 100-240 V, 50/60 Hz Gross weight 300 g 1 further specification on the full record.
Typical applications
- Neutralising charge on plastic and glass weighing vessels
- Weighing dry powders that creep or scatter
- Weighing filters, films and plastic parts
- Semi-micro and micro weighing in dry air
- Handling toxic powders that must not disperse
Also known as
- Antistatic ionizer
- Static eliminator for balances
- Balance de-ioniser
- Static neutraliser
- Ionising blower for weighing
Semi-Micro / Analytical Balance, Touch Screen, 102 g / 220 g
Dual-range semi-micro and analytical balance reading to 0.01 mg on the 102 g range and 0.1 mg on the 220 g range, with internal calibration, a 5-inch touch screen and a GLP database.
IndentCapacity × readability: 102 g × 0.01 mg (semi-micro range); 220 g × 0.1 mg (analytical range)
Specification for Semi-Micro / Analytical Balance, Touch Screen, 102 g / 220 g
Specification for Semi-Micro / Analytical Balance, Touch Screen, 102 g / 220 g Capacity × readability 102 g × 0.01 mg (semi-micro range); 220 g × 0.1 mg (analytical range) Repeatability (standard deviation) 0.01 mg on the 102 g range; 0.1 mg on the 220 g range Linearity (±) 0.04 mg on the 102 g range; 0.4 mg on the 220 g range Sensitivity drift 3 ppm/°C Weighing cell Electromagnetic force compensation (EMFC) Calibration Internal calibration Display 5" touch screen Response time ≤ 6 s Pan size 80 mm Windshield dimensions 162 x 171 x 225 mm Operating temperature 15 °C - 25 °C Application modes Piece counting with statistics report, textile function, percentage, check weighing, animal weighing, formulation (recipe) 11 further specifications on the full record.
Typical applications
- Reference standard and impurity standard weighing
- Assay and content uniformity sample preparation
- Standard solution preparation
- Formulation and recipe weighing
- Density determination of solids and liquids
- Piece counting of small components
Also known as
- Semi-micro balance
- Touch screen analytical balance
- 0.01 mg balance
- Dual range analytical balance
- 102 g semi-micro balance
Semi-Micro / Analytical Balance, Touch Screen, 81 g / 220 g
Dual-range semi-micro and analytical balance reading to 0.01 mg on the 81 g range and 0.1 mg on the 220 g range, with internal calibration and an antistatic glass windshield.
IndentCapacity × readability: 81 g × 0.01 mg (semi-micro range); 220 g × 0.1 mg (analytical range)
Specification for Semi-Micro / Analytical Balance, Touch Screen, 81 g / 220 g
Specification for Semi-Micro / Analytical Balance, Touch Screen, 81 g / 220 g Capacity × readability 81 g × 0.01 mg (semi-micro range); 220 g × 0.1 mg (analytical range) Repeatability (standard deviation) 0.01 mg on the 81 g range; 0.1 mg on the 220 g range Linearity (±) 0.04 mg on the 81 g range; 0.4 mg on the 220 g range Sensitivity drift (±) 2 ppm/°C Verification scale interval (e) 1 mg Accuracy class as printed Class I Weighing cell Electromagnetic force compensation (EMFC) Calibration Internal calibration Display 4.3" touch screen, time on display, built-in temperature sensor Response time 4-6 s Pan size 90 mm Ø Windshield Glass, antistatic material 13 further specifications on the full record.
Typical applications
- Semi-micro sample and standard weighing
- Standard solution preparation
- Dynamic weighing of unstable loads
- Density determination of solids and liquids
- Piece counting
- Percentage and Σ weighing
Also known as
- Semi-micro balance
- Touch screen semi-micro balance
- 0.01 mg balance
- Dual range analytical balance
- 81 g semi-micro balance