An in-house QC laboratory has a narrow, repeating test list and a strong incentive to keep it running. The purchase pattern reflects that: known reagents in known pack sizes on a predictable cycle, and instruments whose downtime is measured in production loss. Consumable continuity and a responsive spares position matter more here than breadth of catalogue.
Tests run here
- Chemical analysis of cement and clinker
- Ash, moisture and calorific value of fuels
- Tensile, hardness and impact testing of metals
- Viscosity, density and flash point of petroleum products
- Polymer melt flow index and thermal analysis
- Colour, gloss and adhesion of coatings
Governed by
- IS product specifications for the relevant commodity
- ASTM and ISO test methods
- ISO 9001 quality management systems
- BIS product certification (ISI mark) requirements
- filtration
- weighing
- spectroscopy
- physical-properties
What this sector draws on
Analytical Balance, 220 g × 0.1 mg
Four-decimal analytical balance with draught shield and internal or external calibration.
Ex-stockISO/IEC 17025Capacity: 220 g
Specification for Analytical Balance, 220 g × 0.1 mg
Specification for Analytical Balance, 220 g × 0.1 mg Capacity 220 g Readability 0.1 mg (0.0001 g) Repeatability ≤ 0.1 mg Linearity ± 0.2 mg Pan size 90 mm ø Calibration Internal motorised or external OIML class E2 weight Services Installation & commissioning · Calibration · Operator training · Annual maintenance contract Standards
ISO/IEC 17025Typical applications
- Weighing for standard and reagent preparation
- Gravimetric analysis
- Sample weighing for assay
Full record, hazard data and enquiry for Analytical Balance, 220 g × 0.1 mg →
pH Meter, Benchtop, Five-Point Calibration
Microprocessor benchtop pH and mV meter with automatic temperature compensation and up to five-point calibration.
Ex-stockpH range: −2.00 to 16.00
Specification for pH Meter, Benchtop, Five-Point Calibration
Specification for pH Meter, Benchtop, Five-Point Calibration pH range −2.00 to 16.00 pH resolution 0.01 (0.001 on selected models) Accuracy ± 0.01 pH Calibration points Up to 5, with auto buffer recognition Temperature ATC, −10 to 110 °C Output RS-232 / USB, optional printer Services Installation & commissioning · Calibration · Operator training · Annual maintenance contract · Spares & consumables Typical applications
- pH measurement in water, effluent and process samples
- Pharmaceutical QC pH determination
Full record, hazard data and enquiry for pH Meter, Benchtop, Five-Point Calibration →
UV-Visible Spectrophotometer, Double Beam
Double-beam UV-Vis spectrophotometer for quantitative absorbance and scanning work.
IndentUSP <857>Wavelength range: 190–1100 nm
Specification for UV-Visible Spectrophotometer, Double Beam
Specification for UV-Visible Spectrophotometer, Double Beam Wavelength range 190–1100 nm Spectral bandwidth 1 nm (2 nm and variable on selected models) Wavelength accuracy ± 0.3 nm Photometric range −0.3 to 3.0 A Stray light < 0.05% T at 220 nm Software PC control; 21 CFR Part 11 package to order Services Installation & commissioning · Calibration · Validation & qualification · Operator training · Annual maintenance contract · Spares & consumables Standards
USP <857>Typical applications
- Quantitative assay by absorbance
- COD, nitrate, phosphate and metals colorimetry
- Dissolution and content uniformity testing
Full record, hazard data and enquiry for UV-Visible Spectrophotometer, Double Beam →
Kjeldahl Digestion and Distillation Unit
Digestion block with fume scrubber and steam distillation unit for total nitrogen and crude protein determination.
IndentDigestion positions: 3, 6, 8 or 12
Specification for Kjeldahl Digestion and Distillation Unit
Specification for Kjeldahl Digestion and Distillation Unit Digestion positions 3, 6, 8 or 12 Digestion temperature Up to 450 °C, PID controlled Fume scrubber Water aspirator or recirculating, with neutralisation Distillation Steam generator with automatic alkali dosing Recovery ≥ 99.5% on ammonium sulphate reference Site preparation Required — foundation or utilities Services Installation & commissioning · Calibration · Operator training · Annual maintenance contract · Spares & consumables Typical applications
- Crude protein in food and feed
- Total Kjeldahl nitrogen in water and effluent
- Nitrogen in soil and fertiliser
Full record, hazard data and enquiry for Kjeldahl Digestion and Distillation Unit →
Conductivity / TDS Meter, Benchtop and Portable
Conductivity, TDS, salinity and resistivity measurement with automatic temperature compensation.
Ex-stockUSP <645>Conductivity range: 0.01 µS/cm to 200 mS/cm, auto-ranging
Specification for Conductivity / TDS Meter, Benchtop and Portable
Specification for Conductivity / TDS Meter, Benchtop and Portable Conductivity range 0.01 µS/cm to 200 mS/cm, auto-ranging Accuracy ± 0.5% of full scale Cell constants K = 0.1, 1.0 and 10.0 Temperature ATC with selectable coefficient Services Calibration · Operator training · Annual maintenance contract · Spares & consumables Standards
USP <645>Typical applications
- Purified water system monitoring
- Effluent and process water conductivity
- TDS in drinking water
Full record, hazard data and enquiry for Conductivity / TDS Meter, Benchtop and Portable →
Muffle Furnace, 1200 °C
Programmable high-temperature muffle furnace for ashing, loss on ignition and heat treatment.
Ex-stockIS 4032Maximum temperature: 1200 °C (1400 °C on request)
Specification for Muffle Furnace, 1200 °C
Specification for Muffle Furnace, 1200 °C Maximum temperature 1200 °C (1400 °C on request) Chamber sizes 4 L, 7 L, 12 L and 22 L Control PID with digital display; programmable ramp-soak to order Stability ± 5 °C at set point Heating elements Kanthal A1 on ceramic; SiC rods on 1400 °C models Insulation Ceramic fibre Services Installation & commissioning · Calibration · Validation & qualification · Annual maintenance contract · Spares & consumables Standards
IS 4032Typical applications
- Loss on ignition of cement, fly ash and aggregate
- Ash content of coal, food and polymer
- Sulphate and chloride content preparation
Full record, hazard data and enquiry for Muffle Furnace, 1200 °C →
Hot Air Oven, Digital, 250 °C
Forced-convection laboratory oven with stainless steel chamber for drying, moisture determination and dry-heat sterilisation.
Ex-stockIS 2720 (Part 2)Temperature range: Ambient +10 °C to 250 °C (300 °C on request)
Specification for Hot Air Oven, Digital, 250 °C
Specification for Hot Air Oven, Digital, 250 °C Temperature range Ambient +10 °C to 250 °C (300 °C on request) Uniformity ± 2 °C at 105 °C Chamber Stainless steel 304, sizes from 45 L to 336 L Air circulation Forced, with adjustable fresh-air damper Control Digital PID with over-temperature cut-out Services Installation & commissioning · Calibration · Validation & qualification · Annual maintenance contract · Spares & consumables Standards
IS 2720 (Part 2)Typical applications
- Moisture content of soil, aggregate and food
- Drying of glassware and samples
- Dry-heat sterilisation
Full record, hazard data and enquiry for Hot Air Oven, Digital, 250 °C →
Vacuum Oven, Laboratory, 27 Litres
Double-walled 27-litre vacuum oven with a mirror-polished stainless steel 316 chamber and PID control from 50 °C to 200 °C, for drying heat-sensitive materials at reduced pressure.
IndentTemperature range: 50 °C to 200 °C
Specification for Vacuum Oven, Laboratory, 27 Litres
Specification for Vacuum Oven, Laboratory, 27 Litres Temperature range 50 °C to 200 °C Vacuum range 50 to 760 mm of Hg Controller PID digital controller with auto-tune Inner chamber Stainless steel 316, mirror polished Construction Double walled, with stainless steel 304 exterior Observation window Thick tempered glass Shelves Two, removable Capacity 27 litres Working chamber 300 × 300 × 300 mm (12 × 12 × 12 inch) Power 1750 W Power supply 230 V, 50 Hz, single phase, AC Typical applications
- Vacuum drying of heat-sensitive materials
- Uniform drying of laboratory samples
- Industrial drying of heat-sensitive product
Full record, hazard data and enquiry for Vacuum Oven, Laboratory, 27 Litres →
Digital Water Bath, 2 / 4 / 6 / 8 Hole
Stainless steel digital water bath in four sizes from 6 to 24 litres, with 125 mm concentric-ring openings, PID control and a drain valve, for heating samples in beakers and flasks.
IndentNumber of holes, 2H / 4H / 6H / 8H: 2 / 4 / 6 / 8
Specification for Digital Water Bath, 2 / 4 / 6 / 8 Hole
Specification for Digital Water Bath, 2 / 4 / 6 / 8 Hole Number of holes, 2H / 4H / 6H / 8H 2 / 4 / 6 / 8 Volume (approx.), 2H / 4H / 6H / 8H 6 L / 12 L / 18 L / 24 L Linear size (L x W x H), 2H / 4H / 6H / 8H 301 x 157 x 142 mm / 304 x 304 x 138 mm / 305 x 470 x 138 mm / 305 x 610 x 138 mm Hole size 125 mm Cover ring per hole 5 rings per hole Temperature range RT +10°C ~ 100°C Temperature resolution 0.1°C Temperature accuracy 0.5°C Temperature control mode PID, microcomputer program Heater Stainless steel U type heating element Water outlet Independent drain valve Wetted materials Stainless steel pot, stamped inner liner with sealing structure; stainless steel and PC on all water contact surfaces 9 further specifications on the full record.
Typical applications
- Heating biological and biochemical samples
- Cell and bacteria culture at set temperature
- Reagent warming and sample thawing
- Enzyme and serological incubation
- Evaporation and extraction in beakers and flasks
Also known as
- Water bath
- Serological water bath
- Constant temperature water bath
- Multi-hole water bath
- Digital thermostatic bath
Full record, hazard data and enquiry for Digital Water Bath, 2 / 4 / 6 / 8 Hole →
Sodium Chloride
CAS 7647-14-5Sodium chloride in Extra Pure, AR and pharmacopoeial grades for buffers, media and standard preparation.
NaCl · 58.44 g/mol · ≥ 99.5%
Ex-stockEXTRA PUREARIPUSP+1500 g · 5 kg · 25 kg
Specification for Sodium Chloride
Specification for Sodium Chloride Pack sizes 500 g · 5 kg · 25 kg — on request Grades offered
EXTRA PUREARIPUSPMOLECULAR BIOLOGYTypical applications
- Buffer and saline preparation
- Microbiological media
- Argentometric titration standard
Potassium Chloride
CAS 7447-40-7Potassium chloride for conductivity standards, electrode filling solution and buffer work.
KCl · 74.55 g/mol · ≥ 99.5%
Ex-stockEXTRA PUREARIPUSP500 g · 5 kg
Specification for Potassium Chloride
Specification for Potassium Chloride Pack sizes 500 g · 5 kg Grades offered
EXTRA PUREARIPUSPTypical applications
- Conductivity standard solution preparation
- pH electrode filling solution (3 M / saturated)
- Ionic strength adjustment
Full record, hazard data and enquiry for Potassium Chloride →
Sodium Carbonate Anhydrous
CAS 497-19-8Anhydrous soda ash, the primary standard for acid standardisation.
Na₂CO₃ · 105.99 g/mol · ≥ 99.5%
Ex-stockEXTRA PUREARAR/ACS500 g · 5 kg
Specification for Sodium Carbonate Anhydrous
Specification for Sodium Carbonate Anhydrous Pack sizes 500 g · 5 kg Grades offered
EXTRA PUREARAR/ACSTypical applications
- Primary standard for standardising acid titrants
- Alkali fusion
- Water hardness and alkalinity determination
Also known as
- Soda ash
- Washing soda (anhydrous)
Full record, hazard data and enquiry for Sodium Carbonate Anhydrous →
Sodium Bicarbonate
CAS 144-55-8Sodium bicarbonate in AR and pharmacopoeial grades for buffers and culture media.
NaHCO₃ · 84.01 g/mol · ≥ 99.5%
Ex-stockEXTRA PUREARIPUSP500 g · 5 kg
Specification for Sodium Bicarbonate
Specification for Sodium Bicarbonate Pack sizes 500 g · 5 kg Grades offered
EXTRA PUREARIPUSPTypical applications
- Carbonate buffer preparation
- Cell culture media
- Acid neutralisation
Also known as
- Sodium hydrogen carbonate
- Baking soda
Full record, hazard data and enquiry for Sodium Bicarbonate →
Potassium Permanganate
CAS 7722-64-7Permanganate crystals for redox titration, COD determination and oxygen demand testing.
KMnO₄ · 158.03 g/mol · ≥ 99%
Ex-stockEXTRA PUREARAR/ACS500 g · 5 kg · 25 kg
Specification for Potassium Permanganate
Specification for Potassium Permanganate Pack sizes 500 g · 5 kg · 25 kg — on request Signal word Danger Transport UN1490 · Packing group II Grades offered
EXTRA PUREARAR/ACSTypical applications
- Permanganometric titration
- Permanganate value / oxygen absorbed in water analysis
- Oxidation in organic synthesis
Full record, hazard data and enquiry for Potassium Permanganate →
Hydrochloric Acid
CAS 7647-01-0Strong mineral acid for digestion, titration and pH adjustment, supplied from Extra Pure through AR to trace-metal ultrapure grade.
HCl · 36.46 g/mol · 35–37% w/w (also supplied at 32%, 25% and 10%)
Ex-stockEXTRA PUREARAR/ACSULTRAPURE2 × 500 ml · 4 × 2.5 L · 25 L carboy · 35 kg / 200 L drum
Specification for Hydrochloric Acid
Specification for Hydrochloric Acid Pack sizes 2 × 500 ml (carton) · 4 × 2.5 L (carton) · 25 L carboy · 35 kg / 200 L drum — on request HSN code 28061000 Signal word Danger Transport UN1789 · Packing group II Grades offered
EXTRA PUREARAR/ACSULTRAPURETypical applications
- Acid digestion of samples prior to AAS and ICP analysis
- Standardised titrant preparation
- pH adjustment in buffer preparation
- Cleaning and passivation of glassware
Also known as
- Muriatic acid
- Hydrogen chloride solution
- HCl
Full record, hazard data and enquiry for Hydrochloric Acid →
Sulphuric Acid 98%
CAS 7664-93-9Concentrated sulphuric acid for digestion, dehydration and titrimetry, in Extra Pure, AR and trace-metal grades.
H₂SO₄ · 98.08 g/mol · 98% w/w
Ex-stockEXTRA PUREARAR/ACSULTRAPURE2 × 500 ml · 2 × 5 L · 4 × 2.5 L · 35 kg carboy
Specification for Sulphuric Acid 98%
Specification for Sulphuric Acid 98% Pack sizes 2 × 500 ml (carton) · 2 × 5 L (carton) · 4 × 2.5 L (carton) · 35 kg carboy — on request HSN code 28070010 Signal word Danger Transport UN1830 · Packing group II Grades offered
EXTRA PUREARAR/ACSULTRAPURETypical applications
- Kjeldahl digestion for total nitrogen and crude protein
- COD determination
- Sample digestion prior to elemental analysis
- Acid–base titration
Also known as
- Oil of vitriol
- H2SO4
Full record, hazard data and enquiry for Sulphuric Acid 98% →
Nitric Acid
CAS 7697-37-2Oxidising mineral acid for microwave and hot-plate digestion, available to ACS specification and in sub-ppb trace-metal grade.
HNO₃ · 63.01 g/mol · 69–70% w/w (also 65% and 60%)
Ex-stockEXTRA PUREARAR/ACSULTRAPURE2 × 500 ml · 4 × 2.5 L · 25 L carboy
Specification for Nitric Acid
Specification for Nitric Acid Pack sizes 2 × 500 ml (carton) · 4 × 2.5 L (carton) · 25 L carboy — on request HSN code 28080010 Signal word Danger Transport UN2031 · Packing group II Grades offered
EXTRA PUREARAR/ACSULTRAPURETypical applications
- Microwave-assisted acid digestion
- Preservation of water samples for metals analysis
- Acid washing of labware for trace analysis
Orthophosphoric Acid 85%
CAS 7664-38-2Phosphoric acid for mobile-phase pH control and general analysis, including a dedicated HPLC grade.
H₃PO₄ · 98.00 g/mol · 85% w/w
Ex-stockEXTRA PUREARHPLC500 ml · 2.5 L · 35 kg carboy
Specification for Orthophosphoric Acid 85%
Specification for Orthophosphoric Acid 85% Pack sizes 500 ml · 2.5 L · 35 kg carboy — on request HSN code 28092010 Signal word Danger Transport UN1805 · Packing group III Grades offered
EXTRA PUREARHPLCTypical applications
- pH adjustment of HPLC mobile phases
- Buffer preparation
- Metallography and steel analysis
Full record, hazard data and enquiry for Orthophosphoric Acid 85% →
Acetic Acid Glacial 99.5%
CAS 64-19-7Glacial acetic acid across Extra Pure, AR and pharmacopoeial grades, with HPLC grade for chromatography.
CH₃COOH · 60.05 g/mol · ≥ 99.5%
Ex-stockEXTRA PUREARHPLCIP+1500 ml · 1 L · 2.5 L · 25 L
Specification for Acetic Acid Glacial 99.5%
Specification for Acetic Acid Glacial 99.5% Pack sizes 500 ml · 1 L · 2.5 L · 25 L — on request HSN code 29152100 Signal word Danger Transport UN2789 · Packing group II Grades offered
EXTRA PUREARHPLCIPUSPTypical applications
- Buffer and mobile-phase preparation
- Histological fixative preparation
- Non-aqueous titration
Full record, hazard data and enquiry for Acetic Acid Glacial 99.5% →
Adapter Cone - Flexible Tubing
Adapter Cone - Flexible Tubing. Borosilicate glass 3.3. 5 sizes, 14 / 23 to 10 / 19.
Indent14 / 23 · 19 / 26 · 24 / 29 · 29 / 32 · 10 / 19
Specification for Adapter Cone - Flexible Tubing
Specification for Adapter Cone - Flexible Tubing Material Borosilicate glass 3.3 Sizes 14 / 23 · 19 / 26 · 24 / 29 · 29 / 32 · 10 / 19 14 / 23 5 per case · Cat. 8836A14 19 / 26 5 per case · Cat. 8836A19 24 / 29 5 per case · Cat. 8836A24 29 / 32 5 per case · Cat. 8836A29 10 / 19 5 per case · Cat. 8836B10 14 / 23 5 per case · Cat. 8836B14 19 / 26 5 per case · Cat. 8836B19 24 / 29 5 per case · Cat. 8836B24 29 / 32 5 per case · Cat. 8836B29 Also known as
- Cat. 8836
Full record, hazard data and enquiry for Adapter Cone - Flexible Tubing →
Adapter Cone / Rubber Tubing
Adapter Cone / Rubber Tubing. Borosilicate glass 3.3. 5 sizes, 10 / 19 to 29 / 32.
Indent10 / 19 · 14 / 23 · 19 / 26 · 24 / 29 · 29 / 32
Specification for Adapter Cone / Rubber Tubing
Specification for Adapter Cone / Rubber Tubing Material Borosilicate glass 3.3 Sizes 10 / 19 · 14 / 23 · 19 / 26 · 24 / 29 · 29 / 32 10 / 19 5 per case · Cat. 8835A10 14 / 23 5 per case · Cat. 8835A14 19 / 26 5 per case · Cat. 8835A19 24 / 29 5 per case · Cat. 8835A24 29 / 32 5 per case · Cat. 8835A29 Also known as
- Cat. 8835
Full record, hazard data and enquiry for Adapter Cone / Rubber Tubing →
Adapter Cones Screw Thread
Adapter Cones Screw Thread. Borosilicate glass 3.3. 4 sizes, 14 / 23 to 29 / 32.
Indent14 / 23 · 19 / 26 · 24 / 29 · 29 / 32
Specification for Adapter Cones Screw Thread
Specification for Adapter Cones Screw Thread Material Borosilicate glass 3.3 Sizes 14 / 23 · 19 / 26 · 24 / 29 · 29 / 32 14 / 23 5 per case · Cat. 8840A14 19 / 26 5 per case · Cat. 8840A19 24 / 29 5 per case · Cat. 8840A24 29 / 32 5 per case · Cat. 8840A29 Also known as
- Cat. 8840
Full record, hazard data and enquiry for Adapter Cones Screw Thread →
Adapter Receiver — Bent with Vent
Adapter Receiver, Bent with Vent. Borosilicate glass 3.3. 5 sizes, 14 / 23 to 29 /32.
Indent14 / 23 · 19 /26 · 19 / 26 · 24 / 29 · 29 /32
Specification for Adapter Receiver — Bent with Vent
Specification for Adapter Receiver — Bent with Vent Material Borosilicate glass 3.3 Sizes 14 / 23 · 19 /26 · 19 / 26 · 24 / 29 · 29 /32 14 / 23 joint 14 / 23 · 5 per case · Cat. 8839614 19 /26 joint 19 / 26 · 5 per case · Cat. 8839619 19 / 26 joint 24 / 29 · 5 per case · Cat. 8839719 24 / 29 joint 24 / 29 · 5 per case · Cat. 8839624 29 /32 joint 29 / 32 · 5 per case · Cat. 8839629 Also known as
- Cat. 8839
- Adapter Receiver
Full record, hazard data and enquiry for Adapter Receiver — Bent with Vent →
Adapter Receiver — Multiple Connectivity
Adapter Receiver, Multiple Connectivity. Borosilicate glass 3.3. 2 sizes, 14 / 23 to 19 / 26.
Indent14 / 23 · 19 / 26
Specification for Adapter Receiver — Multiple Connectivity
Specification for Adapter Receiver — Multiple Connectivity Material Borosilicate glass 3.3 Sizes 14 / 23 · 19 / 26 14 / 23 joint 14 / 23 · 5 per case · Cat. 8844614 14 / 23 joint 19 / 26 · 5 per case · Cat. 8844714 19 / 26 joint 19 / 26 · 5 per case · Cat. 8844619 Also known as
- Cat. 8844
- Adapter Receiver
Full record, hazard data and enquiry for Adapter Receiver — Multiple Connectivity →
Send us your test schedule for this laboratory.
We will map it to grades, pack sizes and instrument specifications, and flag anything that is over-specified for what you are actually measuring.